www.omega.com
Specifications liable to change without prior warning Data Sheet - Issue 01 09/2012 S.T.L Applies to OM-EL-WiFi-TP Page 2 of 3
Specifications
Minimum
Typical
Maximum
Unit
Battery life
>1*
Year
USB supply voltage
4.5v
5.5v
V d.c.
Probe temperature measurement range
-40 (-40)
+125 (+257)
°C (°F)
Internal resolution
+/- 0.1
°C
Probe temperature accuracy (overall error)
+/- 0.5
+/- 2.0
°C
Probe clip operating temperature range
-40 (-40)
+100 (212)
°C (°F)
Logging rate (user configurable)
Every 10s
30 seconds
Every 12hrs
Transmisson rate
Unit operating temperature range
-20 (-4)
+60 (+140)
°C (°F)
*
Typical but could be less if frequent transmissions
Warning - do not exceed operating temperatures
EXAMPLE OF UNIT WHILST PHYSICALLY CONNECTED TO PC DURING SET-UP
HARDWARE
• Battery: Rechargeable via USB connection
• Microcontroller: ARM MCU
• 1x micro USB Type B (bottom of unit) for connection of unit to PC via USB cable supplied.
• Removable probe: 50cm, 304 stainless steel end cap, high temperature flexible cable with tight bend radius
This sensor stands alone by itself on a horizontal surface and comes with a wall bracket that can be screwed onto a wall or flat surface.
The sensor clips into the bracket.
The sensor is supplied with a thermister probe with an attachment so that the probe can be securely fixed to flat surfaces.
The probe is removable so alternative probes can also be used to meet specific requirements providing they operate within the same
temperature range.
All OM-EL-WiFi-TP sensors are thoroughly tested pre-release but the sensor may experience compatibility issues with certain WiFi networks.
In this instance we recommend the use of network accessories available on the Omega website.