background image

www.omega.com

 

    

Specifications liable to change without prior warning            Data Sheet - Issue 01            09/2012           S.T.L          Applies to OM-EL-WiFi-TP       Page 2 of 3

  

Specifications

Minimum

Typical

Maximum

Unit

Battery life

>1*

Year

USB supply voltage

4.5v

5.5v

V d.c.

Probe temperature measurement range

-40 (-40)

+125 (+257)

°C (°F)

Internal resolution

+/- 0.1

°C

Probe temperature accuracy (overall error)

+/- 0.5

+/- 2.0

°C

Probe clip operating temperature range

-40 (-40)

+100 (212)

°C (°F)

Logging rate (user configurable)

Every 10s

30 seconds

Every 12hrs

Transmisson rate

Unit operating temperature range

-20 (-4)

+60 (+140)

°C (°F)

*

 Typical but could be less if frequent transmissions

    

Warning - do not exceed operating temperatures

EXAMPLE OF UNIT WHILST PHYSICALLY CONNECTED TO PC DURING SET-UP

HARDWARE

• Battery: Rechargeable via USB connection
• Microcontroller: ARM MCU 
• 1x micro USB Type B (bottom of unit) for connection of unit to PC via USB cable supplied.
• Removable probe: 50cm, 304 stainless steel end cap, high temperature flexible cable with tight bend radius

This sensor stands alone by itself on a horizontal surface and comes with a wall bracket that can be screwed onto a wall or flat surface. 
The sensor clips into the bracket.

The sensor is supplied with a thermister probe with an attachment so that the probe can be securely fixed to flat surfaces.

The probe is removable so alternative probes can also be used to meet specific requirements providing they operate within the same 
temperature range.  

All OM-EL-WiFi-TP sensors are thoroughly tested pre-release but the sensor may experience compatibility issues with certain WiFi networks.  
In this instance we recommend the use of network accessories available on the Omega website.