OM-CP-TEMP101A

Product Notes

The OM-CP-TEMP101A is second to none in the compact, portable and low cost data logger class. This 
device can measure and record ambient temperature from -40 °C to 80 °C and is approximately the size of a 
matchbox which allows for easy placement even in tight spaces. 

The OM-CP-TEMP101A features a pushbutton start/stop on the device or can be configured to start and stop 
with the ability to schedule a delayed start up to eighteen months in advance. These features combined with 
the ability to store up to 2,000,000 readings makes the OM-CP-Temp101A the ideal solution for long term 
temperature deployment and monitoring cycles

LEDs

- Green LED blinks: 10 seconds to indicate logging and 15 seconds to indicate delay start mode.
- Red LED blinks: 10 seconds to indicate low battery and/or memory and 1 second to indicate an alarm 

condition.

Password Protection

An optional password may be programmed into the device to restrict access to configuration options. Data 
may be read out without the password

Multiple Start/Stop Mode Activation

- To start device: Press and hold the pushbutton for 5 seconds, the green LED will flash during this time. The 

device has started logging.

- To stop the device: Press and hold the pushbutton for 5 seconds, the red LED will flash during this time. The 

device has stopped logging.

Alarm Settings

Programmable high and low limits; alarm is activated when temperature reaches or exceeds set limits.

Installation Guide

Installing the Interface cable

- OM-CP-IFC200: Insert the device into a USB port. The drivers will install automatically.

Device Operation

Connecting and Starting the data logger

- Once the software is installed and running, plug the interface cable into the data logger.
- Connect the USB end of the interface cable into an open USB port on the computer. 
- The device will appear in the Connected Devices list, highlight the desired data logger.  
- For most applications, select “

Custom Start

” from the menu bar and choose the desired start method, 

reading rate and other parameters appropriate for the data logging application and click “

Start

”. (

Quick 

Start

” applies the most recent custom start options, “

Batch Start

” is used for managing multiple loggers at once, 

Real Time Start

” stores the dataset as it records while connected to the logger.

)

- The status of the device will change to “

Running

”, “

Waiting to Start

” or “

Waiting to Manual Start

”, 

depending upon your start method. 

- Disconnect the data logger from the interface cable and place it in the environment to measure.

Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point 
the device cannot be restarted until it has been re-armed by the computer.