background image

9

INSTRUCTIONS FOR THE INSTALLER

Installation

These Instructions are for the qualified technician, as a guide to the installation,
adjustment and maintenance, according to the laws and standards in force.  Any of
these operations must always be carried out when the appliance has been disconnected
from the electric system.

Installation  (Gas)

This appliance is not provided with a combustion product discharge.  It is
recommended that it be installed in sufficiently aerated places, in terms of the laws
in force. The quantity of air which is necessary for combustion must not be below
2.0 m

3

/h for each kW of installed power.

See table of burner power.

Positioning

(Fig. 5). The appliance can be fitted into a working area as illustrated on the
corresponding figure.
Apply the seal provided over the whole of the area perimeter.

Gas connection

(Fig. 6) Connect the appliance to the gas cylinder or to the installation according to the
prescribed standards in force, and ensure beforehand, that the appliance matches the
type of gas available.  Otherwise, see "Adaptation to various types of gas".
Furthermore, check that the feed pressure falls within the values described on the
table: "User chacteristics".

Rigid/semi rigid metal connection
Carry out the connection with fittings and metal pipes (even flexible pipes) so as to
obtain counter stress the inner parts of the appliance.
N.B. - when the installation has been carried out, check the perfect sealing of the entire
connection system, by using a soapy solution.

Electrical connection
(Fig. 7) Prior to carrying out the electrical connection, please ensure that:
• the plant characteristics are such as to follow what is indicated on the matrix plate

placed at the bottom of the working area;

• that the plant is fitted with an efficient earth connection, following the standards and

law provisions in force.  The earth connection is compulsory in terms of the law.

Should there be no cable and/or plug on the equipment, use suitable absorption
material for the working temperature as well, as indicated on the matrix plate.  Under
no circumstance must the cable reach a
temperature above 50

°

C of the ambient

temperature.
Should a direct connection to the network
be required, it will be necessary to
interpose an omnipolar switch with mi-
nimum aperture between the 3 mm. con-
tacts, dimensioned to bear the plate load
and it must follow the standards in force

Fig. 6

ISO 7/1
ISO 228/1 (FR)

Summary of Contents for OG66XA

Page 1: ...installation and operating instructions OG66XA Cooktop...

Page 2: ...URIES OR DAMAGES ARE CAUSED BY INCORRECT INSTALLATION OR BY UNSUITABLE WRONG OR ABSURD USE The appliance is not intended for use by young children or infirm persons without supervision Young children...

Page 3: ...end of the anti clockwise rotation direction In models with automatic ignition operate the knob as described above pressing simultaneously the corresponding push button The electric spark between the...

Page 4: ...4 Fig 1a...

Page 5: ...5 Fig 1 b...

Page 6: ...itself avoid liquid overflow Therefore after boiling or heating liquids reduce the heat output do not leave the electrical elements plates on with empty pots and pans when cooking is finished rotate t...

Page 7: ...ed out by qualified personnel who must be consulted in case of any functioning anomaly Check periodically the state of conservation of the flexible gas feed pipe In case of leakage call immediately th...

Page 8: ...boiling temperature 4 7 8 medium tender roasts cooking at boiling temperature 5 9 10 high roasts boiled food pan frying of meats 6 10 11 burning heat bring large quantities of liquid to boil fry Fig...

Page 9: ...the feed pressure falls within the values described on the table User chacteristics Rigid semi rigid metal connection Carry out the connection with fittings and metal pipes even flexible pipes so as t...

Page 10: ...ribed above and the accident prevention norms not being respected and followed Adaptation to various types of gas Fig 8 9 Should the appliance be pre set for a different type of gas than that availabl...

Page 11: ...254 wok DUAL 37A 97B 44A 100B 4250 309 fish fast 320 3000 680 Towngas semifast 192 1750 398 G110 8 10 auxiliary 150 1000 227 wok DUAL 150A 350B 3500 794 fish ELECTRICAL PLATES FEED TYPE W ADJUSTMENT...

Page 12: ...possible inaccuracies contained in this pamphlet due to printing or copying errors We reserve the right to make on our own products those changes to be considered necessary or useful without jeopardiz...

Reviews: