INSTRUCTIONS FOR THE INST

ALLER

Installation

These Instructions are for the qualified technician, as a guide to the installation,

adjustment and maintenance, according to the laws and standards in force.  Any of

these operations must always be carried out when the appliance has been disconnected

from the electric system.

Installation  (Gas)

This appliance is not provided with a combustion product discharge.  It is

recommended that it be installed in sufficiently aerated places, in terms of the laws

in force. The quantity of air which is necessary for combustion must not be below

2.0 m

3

/h for each kW of installed power.

See table of burner power.

Positioning

(Fig. 5). The appliance can be fitted into a working area as illustrated on the

corresponding figure.

Apply the seal provided over the whole of the area perimeter.

Gas connection

(Fig. 6) Connect the appliance to the gas cylinder or to the installation according to the

prescribed standards in force, and ensure beforehand, that the appliance matches the

type of gas available.  Otherwise, see "Adaptation to various types of gas".

Furthermore, check that the feed pressure falls within the values described on the

table: "User chacteristics".

Rigid/semi rigid metal connection

Carry out the connection with fittings and metal pipes (even flexible pipes) so as to

obtain counter stress the inner parts of the appliance.

N.B. - when the installation has been carried out, check the perfect sealing of the entire

connection system, by using a soapy solution.

Electrical connection

(Fig. 7) Prior to carrying out the electrical connection, please ensure that:

the plant characteristics are such as to follow what is indicated on the matrix plate

placed at the bottom of the working area;

that the plant is fitted with an efficient

earth connection, following the standards

and law provisions in force.  The earth

connection is compulsory in terms of the

law.

Should there be no cable and/or plug on

the equipment, use suitable absorption

material for the working temperature as

well, as indicated on the matrix plate.  Un-

der no circumstance must the cable reach a

temperature above 50

°

C of the ambient

temperature.

Should a direct connection to the network

Fig. 6

ISO 7/1

ISO 228/1 (FR)

Summary of Contents for OG63XA

Page 1: ...installation and operating instructions OG63XA Cooktop ...

Page 2: ... Towngas semifast 200 1750 398 G110 8 10 auxiliary 150 1000 227 wok 310 340 3500 794 fish 290 3000 680 ELECTRICAL PLATES FEED TYPE W ADJUSTMENT normal Ø 145 Ø 180 1000 1500 commutator 0 6 energy regulator 0 11 fast Ø 145 Ø 180 1500 2000 VITROCERAMIC HEATING ELEMENTS FEED TYPE W ADJUSTMENT triple circuit radiant Ø 145 Ø 180 1200 1700 commutator 0 6 single circuit radiant Ø 145 Ø 180 1200 1700 energ...

Page 3: ...conds as described above after placing it on its maximum value After releasing the knob make sure the burner is actually lit N B we recommend the use of pots and pans with a diameter matching that of the burner thus preventing the flame from escaping from the bottom part and surrounding the pot do not leave any empty pots or pans on the fire do not use any tools for grill cooking on Crystal hobs W...

Page 4: ...hes the type of gas available Otherwise see Adaptation to various types of gas Furthermore check that the feed pressure falls within the values described on the table User chacteristics Rigid semi rigid metal connection Carry out the connection with fittings and metal pipes even flexible pipes so as to obtain counter stress the inner parts of the appliance N B when the installation has been carrie...

Page 5: ... below boiling temperature 4 7 8 medium tender roasts cooking at boiling temperature 5 9 10 high roasts boiled food pan frying of meats 6 10 11 burning heat bring large quantities of liquid to boil fry Fig 5 WARNING CRYSTAL HOBS DO NOT TIGHTEN SCREW A EXCESSIVELY ONE TURN MAX WILL BE SUFFICIENT AFTER CORRECTLY FITTING SHAFT B INTO PLACE AS SHOWN IN THE PICTURE ENSURE THAT THE SUPPORTING SURFACE IS...

Page 6: ...rking area vinegar salt lemon juice etc the wall baffle and the small covers mobile parts of the burner must be washed frequently with boiling water and detergent taking care to remove every possible encrustation Dry carefully and check that none of the burner holes is fully or partially clogged the electrical parts are cleaned with a damp cloth and are lightly greased with lubricating oil when st...