background image

Instructions for Machine Transport 

NOTE: Refrigeration equipment must remain upright to avoid damage to

the compressor In order to prevent the oil contained in the compressor

from flowing into the cooling circuit, it is necessary to always ship, carry,

store and handle this Granita machine in an upright position, following

the instructions located on the packaging. Never ship, carry, store or

handle unit on its side. 

Installation 

1.) Cut banding straps from box and lift the box off the machine (see fig. 1). 

2.) Positioning the machine 

The machine must be well ventilated. Leave an 8” (20 cm) clearance on the  sides

and back of the machine to allow proper ventilation. Installation of the machine

near a heat source should be avoided. Some heat sources you should avoid locating

this unit too close to are ovens, coffee machines, cold or frozen beverage dispensers

or ice machines (equipment with compressors that expel hot air through its vents. An

ambient temperature between 59°F (15°C) and 77°F (25°C) is recommended. 

Connection to Main Power Supply 

• The electrical safety of this Granita machine can only be achieved if the ma-

chine is properly connected to an appropriate grounded receptacle that is in com-

pliance with current national safety standards. Therefore, the manufacturer cannot

be held responsible for damage and/or injury caused by failure to connect the unit

to an appropriate power source. 

• For a safe and correct installation, connect the unit to a dedicated outlet. 

• Do not alter the cord or plug in any way. 

• The entire length of the power supply cord must not, in any way, be com

pressed (bent or bunched together) nor may extension cords be used. 

• Do not obstruct the ventilation and heat dispersion grill vents on the side and

rear panels of the unit. An insufficient ventilation process may reduce the efficiency

of the machine, causing it to function inadequately, and cause serious damage to

the machine. A minimum of eight inches (20cm) clearance is necessary on each side

and behind the unit. 

WARNING: 

THIS UNIT MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID POSSIBLE

FATAL ELECTRICAL SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER CORD IS

PROVIDED WITH A THREE PRONG GROUNDED PLUG. IF A THREE-HOLE GROUNDED

ELECTRICAL OUTLET IS NOT AVAILABLE, USE AN APPROVED METHOD TO GROUND THE

UNIT. DO NOT USE EXTENSION CORDS WITH THIS UNIT. DO NOT “GANG” TOGETHER

WITH OTHER ELECTRICAL DEVICES ON THE SAME OUTLET.

4

Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454

2940 Hwy 14 W, Rochester, MN 55901

Summary of Contents for OFS20

Page 1: ...09 RevA www omegajuicers com www omegajuicers com Eat well drink well and live well with Omega Eat well drink well and live well with Omega OFS20 OFS30 GRANITA MACHINE Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 2: ...Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 3: ... Installation 4 Operating Cleaning Procedures 5 Exploded View 8 Parts List 9 10 Electrical Diagram 11 Warranty 12 TABLE OF CONTENTS Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 4: ...in H 59cm x W 41cm x D 61cm Watts 980 OFS20 Power Requirements Volts 120 240VAC Amps 6 A 3 A Hz 50 60 OFS30 Power Requirements Volts 120 240VAC Amps 8 A 4 A Hz 50 60 Specifications OFS30 OFS20 3 Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 5: ...ounded receptacle that is in com pliance with current national safety standards Therefore the manufacturer cannot be held responsible for damage and or injury caused by failure to connect the unit to an appropriate power source For a safe and correct installation connect the unit to a dedicated outlet Do not alter the cord or plug in any way The entire length of the power supply cord must not in a...

Page 6: ...chandising lid Pour the prepared product into the bowl Do not spill any material on lid or on bowl There is a minimum and maximum fill line on the bowl Do not overfill or run the unit without enough product Running unit with product below the minimum full line may cause damage to the unit Insert the plug into a dedicated electrical outlet Dispensing Product To dispense the product position the cup...

Page 7: ...operly it is important that the cleaning procedures be carried out daily according to the following instructions Turn off the equipment and empty the bowl of its remaining product After draining the product from the unit you can fill the bowl with hot water not boiling to help melt off any sugar deposits Drain the water prior to proceeding to the next step To disassemble the draw valve extract the...

Page 8: ... parts such as the clear plastic auger gears and top mixing bar Reassemble with clean hands Maintenance Warning Disconnect the unit from its power supply prior to performing any maintenance procedures Failure to do so could result in electric shock injury from hazardous moving parts or serious burns from hot surfaces Failure to maintain a clean filter and condenser will cause damage to the unit no...

Page 9: ...EXPLODED VIEW PARTS LIST 8 Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 10: ...17 PSH GL2004 Scraper for Spiral 18 PSH GL2005 Spiral Section 19 PSH GL2006 Clip for Attaching Scraper 20 PSH GL2007 Gear Box 21 PSH GL2008 Box Cap 22 PSH GL2009 Seal 23 PSH GL2010 1 Stirring Motor Coil 24 PSH GL2011 1 Coil 31 PSH GL2028 Bushing for Hardness Control Pin 32 PSH GL2029 Hardness Control Catch 33 PSH GL2030 Hardness Control Screw 34 PSH GL3000 Twisted Spring 35 PSH GL3001 Light Bulb A...

Page 11: ...5036 Fixed Evaporator Cover 59 PSH GL4021 2 UL Support Feet UL 60 PSH GL4022 Cover for PC Board 61 PSH GL4023 BLK Drip Tray Black 62 PSH GL4028 UL Power Cord UL 63 PSH GL1018 1 Subsidiary Fan Motor UL 64 PSH GL3006 1 UL Transformer UL 65 PSH GL3007 Gasket 66 PSH GL3008 Bushing 67 PSH GL3009 3 Protective Switch 20A OFS20 PSH GL3009 4 Protective Switch 30A OFS30 68 PSH GL3010 Terminals Connectors Se...

Page 12: ...Electric Circuit Diagram OFS30 11 Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 13: ...cluding holidays and weekends and reasonable travel not to exceed two 2 hours or one hundred 100 miles round trip any part or assembly of such product which proves to be defective and which upon examination by an ASW P authorized service technician shall disclose to our satisfaction to be defective Nei ther Omega nor Asbury Service Warranty Parts shall be held responsi ble for spoilage of products...

Page 14: ...13 Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 15: ...14 Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Page 16: ... Inc Harrisburg PA 17111 4523 U S A Phone 717 561 1105 Fax 717 561 1298 www omegajuicers com Total Restaurant Supply https totalsupply1 com Toll Free 1 800 944 9304 Local 507 288 9454 2940 Hwy 14 W Rochester MN 55901 ...

Reviews: