background image

10

INSTRUCTIONS FOR THE INSTALLATION TECHNICIAN

Installation

These Instructions are for the qualified technician, as a guide to the installation, adjustment and
maintenance, according to the laws and standards in force.  Any of these operations must always be
carried out when the appliance has been disconnected from the electric system.

Positioning

(Fig. 5 - 5a - 5b). The appliance can be fitted into a working area as illustrated on the figure.  Apply the
seal supplied over the whole perimeter of the working area.

Electrical connection

(Fig. 6 - 6a) Prior to carrying out the electrical connection, please ensure that:
- the plant characteristics are such as to follow what is indicated on the matrix plate placed at the bottom

of the working area;

- that the plant is fitted with an efficient earth connection, following the standards and law provisions in

force.  The earth connection is compulsory in terms of the law.

Should there be no cable and/or plug on the equipment, use suitable absorption material for the
working temperature as well, as indicated on the matrix plate.  Under no circumstance must the cable
reach a temperature above 50

°

C of the ambient temperature.

Should a direct connection to the network be required, it will be necessary to interpose an omnipolar
switch with minimum aperture between the 3 mm. contacts, dimensioned to bear the plate load and it
must follow the standards in force (the yellow/green earth cable must not be interrupted by the switch).
The plug or omnipolar switch must be easily reached on the installed equipment.

The manufacturers decline any responsibility in the event of non-compliance with what is described
above and the accident prevention norms not being respected and followed.

To  avoid all risk, if the power cable becomes damaged, it must only be replaced by the
manufacturer, by an authorised service centre, or by a qualified electrician.

Summary of Contents for OC74TXA

Page 1: ...installation and operating instructions OC74TXA Cooktop...

Page 2: ...OR DOMESTIC USE ONLY THE MANUFACTURER SHALL NOT IN ANY WAY BE HELD RESPONSIBLE FOR WHATEVER INJURIES OR DAMAGES ARE CAUSED BY INCORRECT INSTALLATION OR BY UNSUITABLE WRONG OR ABSURD USE The appliance...

Page 3: ...hat is quite normal N B When one makes use of heating elements we advise receptacles with flat bottom Fig 3 having same diameter or lightly higher than that of the hot area Avoid overflows of liquid t...

Page 4: ...2 3 4 SWITCH USE OF HEATING ELEMENTS switch energy regulator heat intensity 1 1 2 weak 2 3 4 gentle 3 5 6 slow 4 7 8 medium 5 9 10 strong 6 10 11 bright NO OVAL NO YES GRILL Turn the knob to position...

Page 5: ...5 Fig 3 TIPOLOGIA A...

Page 6: ...6 TIPOLOGIA A Fig 3b Abb 3b Afb 3b TIPOLOGIA B Fig 3a...

Page 7: ...7 Fig 5 TIPOLOGIA B Fig 4 Fig 3c...

Page 8: ...8 TIPOLOGIA A Fig 5a TIPOLOGIA B Fig 5b...

Page 9: ...9 Considering contemporaneity factor Considering contemporaneity factor H05RR F3x2 5 H05RR F4x1 5 H05RR F4x1 5 H05RR F5x1 5 H05RR F3x1 5 H05RR F4x0 75 Fig 6 Fig 6a...

Page 10: ...ns in force The earth connection is compulsory in terms of the law Should there be no cable and or plug on the equipment use suitable absorption material for the working temperature as well as indicat...

Page 11: ...lator 0 11 mixed circuit radiant halogen 180 1800 energy regulator 0 11 double circuit radiant 210 120 2100 energy regulator 0 11 double circuit oval radiant 145x250 1800 energy regulator 0 11 double...

Page 12: ...possible inaccuracies contained in this pamphlet due to printing or copying errors We reserve the right to make on our own products those changes to be considered necessary or useful without jeopardiz...