background image

 
 
 
 
 

 

 

Instruction Manual

 

Box Canopy Rangehood 

 

OBC60BX, OBC90BX 

 

Summary of Contents for OBC60BX

Page 1: ...1 Instruction Manual Box Canopy Rangehood OBC60BX OBC90BX...

Page 2: ...ance such as warranty registration manuals features and specifications please visit omegaappliances com au if you are in Australia and omegaappliances co nz if you are in New Zealand or contact our Cu...

Page 3: ...a reserves the right to alter specifications and appearances without notice Contents Important Safety Warnings 1 Appliance Details 2 Installation Instructions 4 5 Operating Instructions 8 Maintenance...

Page 4: ...nded to operate the range hood prior to cooking 13 It is recommended to leave the range hood in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours an...

Page 5: ...Appliance Details Voltage Frequency 220 240V 50Hz Lamp Max 2 x 2W LED Rated Input Power 320W Total Input Power 324W Product Dimensions Model pictured OBC60BX Model pictured OBC90BX General Informatio...

Page 6: ...nd that the tools listed below are readily available List of contents Rangehood including 2 baffle filters x1 Inner flue x1 Outer flue x1 Ducting outlet x1 Rubber gasket x1 Flue support bracket grey x...

Page 7: ...ark at the point where it crosses the line marked in C above E Using the spirit level lightly mark a vertical line from this point up to the ceiling This is the centre line of the range hood Note ENSU...

Page 8: ...he holes drilled as above Using a second person carefully position the range hood so the two teardrops line up with the plastic anchors 3 Using a screwdriver fix the two Screws A refer to page 3 and t...

Page 9: ...les on the rubber gasket and duct outlet with the holes on the top of rangehood body and fix them with 4 Screws C provided see below Fig 3 Fig 3 3 Connect the ducting outlet and 150mm ducting pipe nee...

Page 10: ...two washers into the plastic anchors through the holes on the flue mounting bracket shown in Fig 4 as below Hands tighten Fig 4 4 Check the flue mounting bracket is level and hands tighten the screws...

Page 11: ...lar maintenance is required for the rangehood to operate at optimum performance levels Maintenance The anti grease filters capture the grease particles suspended in the air and are therefore subject t...

Page 12: ...fly valve jammed Contact technician After running for a while motor stop working High temperature safety device activated The kitchen is not sufficiently ventilated The rangehood is installed too near...

Page 13: ...horised Service Centre will at no extra charge if your appliance is readily accessible without the need of special equipment and subject to the terms and conditions of this warranty repair or replace...