11
NOBEL 30 DV CSA
NOBEL 37 DV CSA
kW/HP
30 / 40
37 / 50
bar g
7,5
7,5
10
13
type
FS190
FS190
FS190
FS190
/
l/min
4850
5800
5400
4520
l/min
1985
2680
1715
1705
l
25 / 3.5
25 / 3.5
°C
8
10
kJ/h
102600
126540
/
m3/h
5000
5000
kW
1,1
1,1
mg/m3
2 - 4
2 - 4
type
200 B3B5
200 B3B5
rpm
3600
3600
kW
30
37
kW
32,4
41,4
40,1
39,4
kW/m3/
min
6,68
6,27
7,21
8,7
%
93,3
93,7
IP
54
54
°C
+2/+45
+2/+45
dB(A)
68
70
69
67
V/Ph/Hz
575/3 ~/60
575/3 ~/60
V/Ph/Hz
24/1~/60
24/1~/60
A
36
47
-
IP55 / F
IP55 / F
-
1,20
1,20
°C
110
110
°C
105
105
A
PTC
PTC
bar
14
14
mm
1620
1620
mm
1024
1024
mm
1560
1560
kg
1000
1030
G
1-1/2"
1-1/2“
EN
TECHNICAL FEATURES
Model
Technical features
Working pressure
Air-end
Transmission type
F.a.d. (ISO 1217 - Annex E) Max
F.a.d. (ISO 1217 - Annex E) Min
Oil quantity / topping-up
Max final air temperature above ambient
Re-claimable heat
Fan type
Fan flow rate
Rated motor power cooling fan
Oil carry over
Main electric motor
Main Motor speed
Nominal main motor power
Max. power absorbed,
ventilation included
Specific Power
Main Electrical Motor efficiency
Electrical box protection class
Min and Max working ambient temp.
Noise level (according Pneurop/Cagi
PN2CPTC2)
Electrical data
Voltage
Auxiliary voltage
Max. absorbed current,
ventilation included
Main motor enclosure/
Insualtion class
Main motor service factor
Protection devices
Max oil temperature
Pre-alarm Oil temperature
Motor thermal relay setting
Safety valve setting
Dimensions and weight
Length
Width
Height
Weight
Air outlet size
Radial
Radial
Direct
Direct