7.1: Electrical
Parameter
Value
Comments
Signal Output
Output Voltage Range
up to ±10 VDC into 1 K
W
see notes 3 and 4
Output Residual Noise
<1 mVrms
Output Current
up to ±20 mA into 150
W
load
see note 5
Output Offset Coarse
±5 VDC (approx 10 mA)
fixed
link selectable
±10 VDC (approx 20 mA)
fixed
link selectable
Fine
±2.8 VDC (approx 5.6
mA)
Variable (adds to fixed
offsets)
Temperature Coefficient
Gain
<0.01% FRO/°C
Temperature Coefficient
Offset
<0.01% FRO/°C
Warm-Up
15 minutes recom-
mended
Linearity
<0.1% FRO
Bandwidth (-3dB)
500 Hz typical
Protection (see note 6)
Power Supply
Reverse connection
protected
Inputs and Outputs
Short circuit protected
Transient and ESD Pro-
tected
Certification (see note 7)
Immunity
BS EN61000-6-2:2001
Immunity for Industrial
Environments
Emissions
BS EN61000-6-3:2001
Emission for Residential,
commercial and
light-industrial environ-
ments
7.2: Mechanical and Connections
Parameter
Value
Comments
Transducer
5-pin circular DIN
Power Supply
Internal Terminal Block
Output Signal
Internal Terminal Block
Enclosure - Size
120 x 65 x 40 mm
Excluding connectors
Weight
300 g (0.66 lbs) approx.
Material of Case
Die-Cast Zinc Alloy (painted)