background image

SPECIFICATIONS

Excitation: 

10 Vdc (15 V Max)

Output: 

2 mV/V ± 20%

Accuracy: 

Linearity, Hysteresis and Repeatability Combined:

 10 K = ±0.5% BFSL

> 10 K = ±0.75% BFSL

Zero Balance: 

±4.0% FSO

Operating Temp Range:  

40 to 127°C (-40 to 260°F)

Compensated Temp Range:

16 to 71°C (60 to 160°F)

Thermal Effects:

Zero:

±0.01% FSO/°F

Span:

±0.01% FSO/°F

Safe Overload: 

120% of Capacity

Ultimate Overload: 

200% of Capacity

Bridge Resistance: 

350 

Ω

 (min) > 50 K (700 

Ω

 

 50 K)

Full Scale Deflection: 

0.001" typical

Construction: 

Stainless Steel

Electrical:

5 ft (1.5 m) PFA insulated, shielded cable

IMPORTANT SAFETY INFORMATION

WARNING! 

These components are used under high forces. They should only be installed and
operated by qualified, authorized personnel.

WARNING! 

DO NOT MODIFY THIS LOAD CELL AND ITS COMPONENT PARTS OR SUBSTITUTE
PARTS. Because of the danger of introducing hazards; do not perform any unauthorized
modifications or install substitute parts to the instrument. 

NOTES:

Reviews: