![background image](http://html1.mh-extra.com/html/omega/k181v90/k181v90_instructions-for-installation-and-use-manual_4053149003.webp)
OPERATION
Controls (Fig. 16)
:
Button A: light switch.
Button B: first speed motor ON/OFF switch.
Button C: second speed motor ON/OFF switch.
Button D: third speed motor ON/OFF switch.
E: motor on light.
Pay special attention to the
grease filters
: the grease filters must be replaced periodically: exactly how often depends
on use (at least once every other month). To remove the filter: push inward on the clamp at the handle and pull the filter
downward. Wash out the filter using a neutral soap.
Replacing the charcoal filter:
If the unit is a filtering hood, the charcoal filter must be replaced:
to remove them press
inward on the clamp (Fig. 15) and rotate the filter downward until the 2 tabs can be removed from the housing. the charcoal
filters must be replaced according to use: on the average once every 6 months.
Lighting
: to change the
halogen bulbs
open the cover levering from the proper slots (Fig. 17). Replace with bulbs
of the same type.