INSTALLATION / OPERATION INSTRUCTIONS

GENERAL SPECIFICATIONS

Operating conditions:

Maximum Exposure Temperature:   

 

 

450

o

F (232

o

C)

Width

inches

Length

inches

Total

Watts

Part Number

120VAC

Part Number

240VAC

1

24  

104

HTWT101-002-60F

N/A

1 48 

 

209

HTWT101-004-60F

HTWT102-004-60F

72   

313

HTWT101-006-60F

HTWT102-006-60F

1 96 

 

418

HTWT101-008-60F

HTWT102-008-60F

1 120 

522

HTWT101-010-60F

HTWT102-010-60F

Read and understand this entire 
manual before operating this electric 
heating tape.

STEP 1

Remove heater from box.  Make visual 
inspection of heater.  Do not use if torn or 
damaged.

STEP 2
Installing your heating tape:

 The fl exible 

heating tape can be installed on both a fl at 
and/or curved surface. For a fl at surface, 
lay the heating tape onto the surface to 
be heated. For a curved surface, wrap the 
heating tape onto the surface to be heated 

(A)

. The length of one entire side of the 

heating tape must be in full contact with 
the surface. 

The thermostat (the raised disc) on the 3” 
long oval block must be placed tightly and 
directly against the surface to be heated 

(B)

. Secure the thermostat in place. 

The thermostat should be placed on the 
coldest end of the pipe. The thermostat 
will turn the heater on and off based on 
the temperature of the area of pipe it is 
against. 

Ensure the heating tape is not kinked, 
twisted, or any portion of the tape hanging 
free from the surface 

(C)

Do not over-

lap heating tape on itself (D).

 Attach 

the heating tape to the surface by using 
aluminum tape, fi berglass tape, or a me-
chanical clamping devices which will not 
cause damage to the heating tape.

STEP 3 

Plug power cord into appropriate 
grounded outlet.

A.) Proper Installation

       (pipe and valve)

D.) Incorrect Installation: 

Heating tape overlapped on itself

C.) Incorrect Installation: 

Heating tape hanging free from the surface

B.) Thermostat against surface

•     Built-in Controlling Thermostat set at 60°F (16°C)
• 

Silicone Rubber Extruded Outer Sheath

• 

Moisture and Chemical Resistant

• 

Patented Grounded Heating Element 

• 

Nominal Watts: 6.0in

2

 (0.009mm

2

)

• 

Suitable for Electrically Conductive Surfaces

• 

120 or 240VAC

• 

6ft (2m) power cord with either NEMA 5-15 or 6-15 plug

Reviews: