![background image](http://html1.mh-extra.com/html/omega/htwt-series/htwt-series_user-manual_3924613003.webp)
4
© Copyright 2005 OMEGA ENGINEERING, Inc. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC
5
© Copyright 2005 OMEGA ENGINEERING, Inc. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the
prior written consent of OMEGA ENGINEERING, INC
INSTALLATION / OPERATION INSTRUCTIONS
GENERAL SPECIFICATIONS
Operating conditions:
Maximum Exposure Temperature:
450
o
F (232
o
C)
Width
inches
Length
inches
Total
Watts
Part Number
120VAC
Part Number
240VAC
1
24
104
HTWT101-002-60F
N/A
1 48
209
HTWT101-004-60F
HTWT102-004-60F
1
72
313
HTWT101-006-60F
HTWT102-006-60F
1 96
418
HTWT101-008-60F
HTWT102-008-60F
1 120
522
HTWT101-010-60F
HTWT102-010-60F
Read and understand this entire
manual before operating this electric
heating tape.
STEP 1
Remove heater from box. Make visual
inspection of heater. Do not use if torn or
damaged.
STEP 2
Installing your heating tape:
The fl exible
heating tape can be installed on both a fl at
and/or curved surface. For a fl at surface,
lay the heating tape onto the surface to
be heated. For a curved surface, wrap the
heating tape onto the surface to be heated
(A)
. The length of one entire side of the
heating tape must be in full contact with
the surface.
The thermostat (the raised disc) on the 3”
long oval block must be placed tightly and
directly against the surface to be heated
(B)
. Secure the thermostat in place.
The thermostat should be placed on the
coldest end of the pipe. The thermostat
will turn the heater on and off based on
the temperature of the area of pipe it is
against.
Ensure the heating tape is not kinked,
twisted, or any portion of the tape hanging
free from the surface
(C)
.
Do not over-
lap heating tape on itself (D).
Attach
the heating tape to the surface by using
aluminum tape, fi berglass tape, or a me-
chanical clamping devices which will not
cause damage to the heating tape.
STEP 3
Plug power cord into appropriate
grounded outlet.
A.) Proper Installation
(pipe and valve)
D.) Incorrect Installation:
Heating tape overlapped on itself
C.) Incorrect Installation:
Heating tape hanging free from the surface
B.) Thermostat against surface
• Built-in Controlling Thermostat set at 60°F (16°C)
•
Silicone Rubber Extruded Outer Sheath
•
Moisture and Chemical Resistant
•
Patented Grounded Heating Element
•
Nominal Watts: 6.0in
2
(0.009mm
2
)
•
Suitable for Electrically Conductive Surfaces
•
120 or 240VAC
•
6ft (2m) power cord with either NEMA 5-15 or 6-15 plug