background image

Safeguards and Precautions

1.

Read and follow all instructions in this manual carefully,
and retain this manual for future reference.

2.

Do not use this instrument in any manner inconsistent
with these operating instructions or under any
conditions that exceed the environmental
specifications stated.

3.

Making measurements in close proximity to rotating
equipment can be dangerous.  Keep all loose clothiing
and hair away from exposed moving machinery.
Properly replace all machinery guards after
completing measurement.

4.

The socket on the front of the instrument is for use
with a remote charger.  Only use model R-5 (115 Vac)
or R-6 (230 Vac) rechargers to charge the instrument.

5.

The HHT21A has a laser beam
light source.  Do not view the
laser beam directly as it could be
hazardous to the eyes.  Do not
point the laser beam into another
person’s eyes.  Do not view the
laser beam with telescopic
devices.

6.

With exception of replacing the batteries, this
instrument is not user serviceable.  For technical
assistance, contact the sales organization from which
you purchased the product.

AVOID EXPOSURE

LASER RADIATION IS EMITTED

FROM THIS APERTURE

LASER RADIATION

AVOID DIRECT EYE EXPOSURE

PEAK POWER
WAVELENGTH

3mw
650nm

CLASS IIIA LASER PRODUCT

NOTES

Summary of Contents for HHT21A

Page 1: ...s Flowmeters Flow Computers 䡺 Air Velocity Indicators 䡺 Turbine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Ap...

Page 2: ...er specification misapplication misuse or other operating conditions outside of OMEGA s control Components which wear are not warranted including but not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from th...

Page 3: ...The socket on the front of the instrument is for use with a remote charger Only use model R 5 115 Vac or R 6 230 Vac rechargers to charge the instrument 5 The HHT21A has a laser beam light source Do not view the laser beam directly as it could be hazardous to the eyes Do not point the laser beam into another person s eyes Do not view the laser beam with telescopic devices 6 With exception of repla...

Page 4: ...t in charging network which works in conjunction with the optional NiCad batteries The optional recharger plugs into the single jack located next to the optical lens at the front end of the instrument Fourteen to sixteen hours is required for a complete recharge When the battery voltage in the HHT21A is getting low the display will blink LO BAT to indicate that the batteries need to be replaced NO...

Page 5: ...e laser beam with telescopic devices Time Base Crystal controlled Power Source 4 AA batteries Recharger socket provided for optional rechargeable batteries Recharger Input Max input 7 8 Vdc 50mA Temperature 41 F 5 C to 104 F 40 C Humidity Maximum relative humidity 80 for temperature up to 88 F 31 C decreasing linearly to 50 relative humidity at 104 F 40 C 4 Remote Internal Switch Internal Optics L...

Page 6: ...bushing at the base of the handle 3 When the trigger is released the HHT21A will hold the last measurement taken and display it for up 90 seconds On very small shafts the HHT21A will work down to a reflective tape size of approximately 1 8 inch 3 2 mm square However with this small tape size it would be necessary to operate the instrument very close to the rotating shaft and insure it is held stea...

Reviews: