7
SELECT Function Button
(DC/AC),(
W
W
W
W
W
/
/
)
The SELECT Function button is Yellow in color. Press it to toggle to the alternate
function (AC, Audible continuity, Diode and capacitance) shown in Yellow on the
meter face.
Voltage Measurements
1. Connect the red test lead to the "V
W
" jack and the black test lead to the "COM"
jack.
2. Set the Function/Range switch to the desired voltage function.
3. Connect the test leads to the device or circuit being measured.
4. For dc, a (-) sign is displayed for negative polarity; positive polarity is implied.
Frequency Measurements
1. Set the Function/Range switch to the ACV position, and then press Hz-%
button toggle the voltage/frequency/duty cycle mode.
2. Connect the red test lead to the "V
W
" jack and the black test lead to the "COM"
jack.
3. Connect the test leads to the point of measurement and read the frequency
from the display.