Note: Unplug the test leads and thermocouple probes from

the multimeter before making any capacitance or
inductance measurement.

Capacitance Measurements

Do Not apply external voltage to the Cx Lx sockets. Make sure

that the capacitor is fully discharged, otherwise damage to the
meter may result.
1. Set the Function switch to the desired capacitance range (µF to

nF).

2. Insert the capacitor leads into the Cx Lx sockets.
3. Read the capacitance value.

Inductance Measurements

1. Set the Function switch to the desired inductance range (mH to

H).

2. Insert the inductor leads into the Cx Lx sockets.
3. Read the inductance value.

Diode Tests

1. Connect the red test lead to the "V

" jack and the black test

lead to the "COM" jack.

2. Set the Function/Range switch to the "

" position.

3. Turn off power to the circuit under test.
4. Touch probes to the diode. A forward-voltage drop is about 0.6V

(typical for a silicon diode).

5. Reverse probes. If the diode is good, OL is displayed. If  the

diode is shorted, ".000" or another number is displayed.

6. If the diode is open, OL is displayed, in both directions.
7. If the junction is measured in a circuit and a low reading is

obtained with both lead connections, the junction may be
shunted by a resistance of less than 1K

. In this case the diode

must be disconnected from the circuit for accurate testing.

Logic Measurements

1. Set the Function/Range switch to the Logic position.
2. Connect the red test lead to the "V

" jack and the black test

lead to the "COM" jack.

3. Connect the red test lead to the test point and the black lead to

the common bus of the logic circuit.

4. A " "on the display indicates TTL logic high and a " " indicates

a TTL logic low. Both indicators are on when the point of
measurement is toggling high and low.

SPECIFICATIONS

Display:  Backlit liquid crystal display (LCD) with a maximum

digital reading of 43000 counts. Includes an Analog Bar Graph
of 40 counts.

Display Resolution:

Range:

0-4.3

.0001

0-43

.001

0-430

.01

0-4300

.1

0-43000

1

Polarity: Automatic, positive implied, negative polarity indication.
Overrange: "OL" or "-OL" is displayed.
Low battery indication: The "

" is displayed when the battery

voltage drops below the operating level.

Measurement rate:

2/sec, nominal; 1/sec, temperature.
20/sec, Analog display.

Operating Environment: 0°C to 40°C at <70% relative humidity.
Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery

removed from meter.

Accuracy: Stated accuracy at 23°C ± 5°C, <75% relative humid-

ity.

Safety: According to EN61010-1 protection class II overvoltage

category (CAT II 600V) pollution degree 2.

Auto Power off: 30minutes after rotary switch and push button no

changes. (except MAX/MIN function)

Power: 6 pcs 1.5V (AA size).

DC Adaptor :DC 9Vmin. - 12Vmax. (LOAD 50mA min.) Use a
certified (CE, VDE) current limited adapter.

Battery life: 100 hours typical.

Dimensions: 202mm (H) x 100mm (W) x 50mm (D).
Weight: Approx. 18.5 oz. (525g) including battery.
Accessories: The unit comes with a protective Rubber Boot, a

pair of test leads, 6 AA size Batteries, One Spare fuse, Type K
Beaded wire thermocouple, and the instruction manual.

Tripod Mount: ¼" - 20 UNC.

Summary of Contents for HHM290

Page 1: ......

Page 2: ...e mail czech omega com France 9 rue Denis Papin 78190 Trappes Tel 33 0 130 621 400 FAX 33 0 130 699 120 Toll Free in France 0800 4 06342 e mail france omega com Germany Austria Daimlerstrasse 26 D 75...

Page 3: ...atent No 0644408 Other Patents Pending 1 SAFETY INFORMATION Do Not use the meter if the meter or the test leads look damaged or if you suspect that the meter is not operating properly This meter is no...

Page 4: ...n tampered with or shows evidence of having being damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating condi...

Page 5: ...screws from the back of the meter and lift off the battery case Replace F1 only with the original type 10A 600V fast acting fuse Replace F2 only with the original type 0 5A 250V fast acting ceramic f...

Page 6: ...laser beam for positioning 7 Adjust the Emissivity button until the meter reads the same temperature measured via the thermocouple probe Read the new Emissivity setting Measurement Considerations 1 T...

Page 7: ...f automatically after 30 seconds Button Press hold to turn on the laser beam Release the button to turn off the laser beam When the laser beam is on a laser icon appears on the display There is a swit...

Page 8: ...eingmeasured CONTINUITY Audible indication 30 Overload protection 500VDC or AC rms DIODE TEST Accuracy 3 0 rdg 3dgts Resolution 100 V Test current 1 0 0 6mA Test voltage 3 5V LOGIC TEST Threshold Logi...

Page 9: ...Degree Celsius C or DegreeFahrenheit F TochangethetemperatureEngineering unit press the button 5 Press the button to display T1 T2 or T1 T2 DC VOLTS Ranges 430mV manual 4 3V 43V 430V 1000V Resolution...

Page 10: ...o the V jack and the black test lead to the COM jack 3 Connect the red test lead to the test point and the black lead to the common bus of the logic circuit 4 A on the display indicates TTL logic high...

Reviews: