OPERATION

Before taking any measurements, read the Safety Information Section.

Always examine the instrument for damage, contamination (excessive dirt,
grease, etc.) and defects. Examine the test leads for cracked or frayed
insulation. If any abnormal conditions exist do not attempt to make any
measurements.

Max. Hold Feature

Press "MAX" to toggle in and out of the Maximun Hold mode.(holding the
highest reading.) In the MAX mode, the MAX annunciator is displayed and
maximun reading are stored in display register, If the new reading is higher
than the reading being displayed, the higher reading is transferred to the
display register. A "higher" reading is defined as the reading with the higher
absolute value.
The MAX hold function is also available in the frequency count mode. The
counter autoranging feature is disable when MAX hold is selected.

Voltage Measurements

1. Connect the red test lead to the "V

W

" jack and the black test lead to the

"COM" jack.

2. Set the Function/Range switch to the desired voltage range and press the

"AC/DC"  switch to toggle between  the desired voltage type. If magnitude
of voltage is not known, set switch to the highest range and reduce until a
satisfactory reading is obtained.

3. Connect the test leads to the device or circuit being measured.
4. For dc, a (-) sign is displayed for negative polarity; positive polarity is implied.

Summary of Contents for HHM15

Page 1: ...OMEGA HHM15 Digital Multimeter...

Page 2: ...l Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic R...

Page 3: ...across a high voltage high energy power source when the meter is set up for mA measurement may be very hazardous 3 Turn off power to the circuit under test before cutting unsoldering or breaking the...

Page 4: ...rating Environment 0 C to 40 C at 70 relative humidity Storage Temperature 20 C to 60 C 0 to 80 R H with battery removed from meter Accuracy Stated accuracy at 23 C 5 C 75 relative humidity Safety Acc...

Page 5: ...500Hz Ranges 400mV 4V 40V 400V 750V Resolution 100 V Accuracy 1 0 rdg 4dgts on 400mV to 400V ranges 2 0 rdg 4dgts on 750V range Input impedance 10MW Overload protection 500VDC or AC rms on 400mV range...

Page 6: ...acy 0 8 rdg 4dgts on 400W range 0 8 rdg 2dgts on 4KW to 4MW ranges 3 0 rdg 4dgts on 40MW range 5 0 rdg 20dgts 10dgts on 4000MW range Open circuit volts 0 6Vdc 3 0Vdc on 400W and 4000MW ranges Overload...

Page 7: ...F range 27Hz INDUCTANCE Ranges 4mH 40mH 400mH 4H 40H Accuracy 5 0 rdg 20dgts on 4mH range 5 0 rdg 10dgts on other ranges Test frequency 4mH 40mH ranges 1kHz 400mH 4H ranges 270Hz 40H range 27Hz Test c...

Page 8: ...8V Logic Lo 0 8 0 5V Indication 40 msec beep at logic low Frequency response 20MHz Detectable pulse width 25nS Pulse limits 30 70 duty Overload protection 500VDC or AC rms TRANSISTOR hFE Ranges 0 1000...

Page 9: ...d the higher reading is transferred to the display register A higher reading is defined as the reading with the higher absolute value The MAX hold function is also available in the frequency count mod...

Page 10: ...th where the measurement is to be taken Connect the meter in series with the circuit 5 Use caution when measuring 10 amps on 10A range for 60s please waiting for 10 minutes for next measurement of 10...

Page 11: ...ubtracted to obtain the actual resistance of 1100MW WARNING The accuracy of the functions might be slightly affected when exposed to a radiated electromagnetic field environment eg radio telephone or...

Page 12: ...z position 2 Connect the red test lead to the VW jack and the black test lead to the COM jack 3 Connect the test leads to the point of measurement and read the frequency from the display Logic Measure...

Page 13: ...n diode 5 Reverse probes If the diode is good display will be between 2 800V and 3 200V If the diode is shorted 000 or another number is displayed 6 If the diode is open display will be between 2 800V...

Page 14: ...se Remove the battery from battery contacts Fuse Replacement If no current measurements are possible check for a blown overload protec tion fuse There are two fuses F1 for the mA jack and F2 for the 1...

Page 15: ...ty or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipmen...

Page 16: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Reviews: