background image

INTRODUCTION

The HH506RA is a portable digital thermometer that

measures external thermocouples of type K, J, R, S, T, E,
and N. The thermocouple types comply with the NIST - ITS

90 standard reference temperature/voltage tables. The

thermometer features a dual thermocouple input, an adjust-
able T/C offset and an RS-232 interface for uploading data
to a PC using optional software and cable.

SAFETY INFORMATION

To avoid electrical shock do not use the device when 

the working voltages exceed 24V AC or DC. To avoid
damages to the instrument and/or physical burns, do not
make measurements in microwave ovens. Avoid sharp
bending of the thermocouple leads to prolong its life,
especially near the connector.

WARNING

To avoid electrical shock, do not use this instrument

when working voltages at the measurement surface

are over 24V AC or DC.

WARNING

To avoid damage or burns, do not take temperature

measurements in microwave ovens.

CAUTION

Repeated sharp flexing can break the thermocouple

leads. To prolong lead life, avoid sharp bends in the

leads, especially near the connector.

GENERAL

Displays:

The Main and Second display panels are 4 1/2 digit liquid
crystal display (LCD) with maximum reading of 19999.
These panels are used for displaying the value of T1 or T2.
The Third panel displays the date, time, or the difference
value of T1 to T2. When the input measurement is
overloaded, the following is displayed “ ––––.–”.

Battery:

Standard 9V battery (NEDA 1604, IEC 6F22 006P)
Battery life is about 100 hours when used with a carbon zinc
battery.

Dimensions:

192 mm (H) x 91 mm (W) x 52.5 mm (D)

Weight:

 365 g

Supplied  Wire:

4 feet Type “K” thermocouple beaded wire (teflon tape
insulated). Maximum insulation temperature 260C
(500F). Wire accuracy 2.2C or 0.75% of reading
(whichever is greater) from 0C to 800C.

ENVIRONMENTAL

Ambient

  

Operating

  

Ranges:

0C to 50C (32F to 122F) <80% R.H.

Storage  Temperature:

-20C to 60C (-4F to 140F) <70% R.H.

Input  Connector:

Accepts standard miniature thermocouple connectors
(flat blades spaced 7.9 mm, center to center).

SPECIFICATIONS

ELECTRICAL

Temperature Scale:

 

Celsius or Fahrenheit

Measurement   Range:

K-TYPE (0.1)

-200C to 1372C,
-328F to 2501F

J-TYPE (0.1)

-210C to 1200C,
-346F to 2192F

T-TYPE (0.1)

-200C to 400C,
-328F to 752F

E-TYPE (0.1)

-210C to 1000C,
-346F to 1832F

R-TYPE (1)

0C to 1767C,
32F to 3212F

S-TYPE (1)

0C to 1767C,
32F to 3212F

N-TYPE (0.1)

-50C to 1300C,
-58F to 2372F

*Based on the ITS-90 temperature standard.
According to temperature standard ITS-90.
Accuracy:
K/J/T/E-TYPE

(0.05% rdg + 0.3C) on -50C to 1370C
(0.05% rdg + 0.7C) on -50C to -210C
(0.05% rdg + 0.6F) on -58F to 2501F
(0.05% rdg + 1.4F) on -58F to -346F

N-TYPE

(0.05% rdg + 0.8C) on -50C to 0C
(0.05% rdg + 0.4C) on 0C to 1300C
(0.05% rdg + 1.6F) on -58F to 32F
(0.05% rdg + 0.8F) on 32F to 2372F

R/S-TYPE

(0.05% rdg + 2C) on 0C to 1767C
(0.05% rdg + 4F) on 32F to 3212F

Temperature  Coefficient:

0.1 times the applicable accuracy specification per C 

from 0C to 18 and 28C to 50C (32F to 64F and 82F
to 122F)

Input   Protecion:

24V dc or 24V ac rms maximum input voltage on any

combination of input pins.
Reading Rate: 2.5 time per second.

HH506RA

K, J, T, E, R, S, N Thermometer

INSTRUCTION

SHEET

M4079/0704

Shop online at: omega.com  e-mail: [email protected]
For latest product manuals: omegamanual.info

HH506RA

MULTILOGGER
THERMOMETER

Servicing North America:

U.S.A.:

One Omega Drive, Box 4047
Stamford, CT 06907-0047

ISO 9001 

Certified

Tel: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

U.S.A. 

Sales Service: 1-800-826-6342/1-800-TC-OMEGA

®

and

Customer Service: 1-800-622-2378/1-800-622-BEST

®

Canada:

Engineering Service: 1-800-872-9436/1-800-USA-WHEN

®

TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA

Mexico:

En Espan˜ol: (001) 203-359-7803 e-mail: [email protected]
FAX: (001) 203-359-7807             [email protected]

Servicing Europe:

Benelux:

Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: +31 (0)20 3472121

FAX: +31 (0)20 6434643

Toll Free in Benelux: 0800 0993344
e-mail: [email protected]

Czech

Frystatska 184, 733 01 Karviná, Czech Republic

Republic:

Tel: +420 (0)59 6311899

FAX: +420 (0)59 6311114

Toll Free: 0800-1-66342

e-mail: [email protected]

France:

11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900

FAX: +33 (0)1 30 57 5427

Toll Free in France: 0800 466 342
e-mail: [email protected]

Germany/

Daimlerstrasse 26, D-75392 Deckenpfronn, Germany

Austria:

Tel:+ 49 (0)7056 9398-0

FAX: +49 (0)7056 9398-29

Toll Free in Germany: 0800 639 7678
e-mail: [email protected]

United 

One Omega Drive, River Bend Technology Centre

Kingdom:

Northbank, Irlam, Manchester

ISO 9002 

M44 5BD United Kingdom 

Certified

Tel: +44 (0)161 777 6611

FAX: +44 (0)161 777 6622

Toll Free in United Kingdom: 0800-488-488
e-mail: [email protected]

OMEGAnet

®

On-Line Service 

Internet e-mail

omega.com

[email protected]

It is the policy of OMEGA Engineering, Inc. to comply with all 
worldwide safety and EMC/EMI regulations that apply. OMEGA 
is constantly pursuing certification of its products to the 
European New Approach Directives. OMEGA will add the CE  
mark to every appropriate device upon certification.

The information contained in this document is believed to be
correct, but OMEGA accepts no liability for any errors it
contains, and reserves the right to alter specifications without 
notice.

WARNING: 

These products are not designed for use in, and

should not be used for, human applications.

Summary of Contents for HH506RA

Page 1: ...HH506RA K J T E R S N Thermometer INSTRUCTION SHEET M4079 0704 Shop online at omega com e mail info omega com For latest product manuals omegamanual info HH506RA MULTILOGGER THERMOMETER ...

Page 2: ...8280 Guyancourt France Tel 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Daimlerstrasse 26 D 75392 Deckenpfronn Germany Austria Tel 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United One Omega Drive River Bend Technology Centre Kingdom Northbank Irlam Manchester ISO 9002 M44 5BD United Kingd...

Page 3: ...s at the measurement surface are over 24V AC or DC WARNING To avoid damage or burns do not take temperature measurements in microwave ovens CAUTION Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector GENERAL Displays The Main and Second display panels are 4 1 2 digit liquid crystal display LCD with maximum readin...

Page 4: ...7C 32F to 3212F N TYPE 0 1 50C to 1300C 58F to 2372F Based on the ITS 90 temperature standard According to temperature standard ITS 90 Accuracy K J T E TYPE 0 05 rdg 0 3C on 50C to 1370C 0 05 rdg 0 7C on 50C to 210C 0 05 rdg 0 6F on 58F to 2501F 0 05 rdg 1 4F on 58F to 346F N TYPE 0 05 rdg 0 8C on 50C to 0C 0 05 rdg 0 4C on 0C to 1300C 0 05 rdg 1 6F on 58F to 32F 0 05 rdg 0 8F on 32F to 2372F R S ...

Page 5: ...is displayed to indicate shift mode To switch back to normal mode press the SHIFT button Setup Mode The operating functions for the setup mode are printed in between two bracket signs on each button Press the SET button in normal mode to switch to setup mode the indicator SET is shown on the left side of the display panel To switch back to normal mode press the SET button Normal Mode The following...

Page 6: ...e overlay are used for scrolling through the saved data Pressing the smaller arrow or retrieves the next saved data Pressing the larger arrow or will retrieve the next ten saved data Pressing the overlay ESC button deactivates the read data function 5 LOG READ button The Log Read function works in conjunction with the log function it is used for reading the log data The log function can be activat...

Page 7: ... Previouslyrecordedreadingsarenoterased PressHOLD button again to resume recording and measurements To prevent accidental loss of MIN MAX and AVG data the MIN MAX function can only be cancelled by pressing and holding down the MIN MAX key for more than 2 seconds The Automatic Power Off function and the power C F REL SET Hi Lo Limits TYPE T1 T2 buttons are also disabled 10 T1 T2 button MAIN display...

Page 8: ...lowing data A maximum of 1024 data can be saved in one log session Press the LOG button again to exit the data log function 6 CLR button The CLR function clears all the saved and logged data in memory When the CLR button is pressed indicator MEM is displayed and the CLR word on upper right of LCD will blink Pressing ENTER button printed on the overlay in white word to clear all saved and logged da...

Page 9: ...ive values Setting is from left to right digit Press the ENTER button to confirm each setting 3 INVT button Interval time setting To setup the time interval for the log function press the INVT button to set the time The indicator INV will be blinking on the topright of the LCD and the previous settings will be displayed Press the number button printed on the overlay in white to change the time int...

Page 10: ...anel should blink Enter from left to right in the following format YY MM DD and HH MM SS Press the Number button printed on the overlay in white word to set the system date and time Press the ENTER button to confirm Exit this function by pressing the ESC button PROCEDURE OF CALIBRATION 1 Make ADJ pin short 2 T2 input for a voltage of 70mV will show a value higher than 28000 2dgts at the third disp...

Page 11: ...omponent upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear i...

Page 12: ... Turbine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Apple IBM Compatibles 䡺 Datalogging Systems 䡺 Recorders P...

Reviews: