Safety

 When found on the product, the following symbols specify: 

 All applicable codes and standards need to be followed in the installation of this product.   
 Adhere to the following safety precautions whenever any type of connection is made to the module:  

 Connect the safety (earth) ground on the power connector first before making any other connections. 

 When connecting to electric circuits or pulse-initiating equipment, open their related breakers. 
 Do not make connections to live power lines. 

 Make connections to the module first; then connect to the circuit to be monitored. 

 Route power wires in a safe manner in accordance with good practice and local codes. 

 Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits. 

 Ensure hands, shoes, and floor are dry before making any connection to a power line. 
 Make sure the unit is turned OFF before making connection to terminals. 

 Make sure all circuits are de-energized before making connections. 

 Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately if defective.  

 Use Copper Conductors in Field Wiring Only, 60/75° C 

Warning:

  Consult 

user documentation. 

Warning:

  Electrical 

Shock Hazard. 

This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or Non-hazardous locations only

WARNING – EXPLOSION HAZARD

 – Substitution of components may impair suitability for Class I, Division 2 

AVERTISSEMENT - RISQUE D'EXPLOSION

 - LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE 

CLASSE 1, DIVISION 2

WARNING – EXPLOSION HAZARD

 – Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. 

AVERTISSEMENT - RISQUE D'EXPLOSION

 - AVANT DE DECONNECTOR L'EQUIPMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE 

NON DANGEREUX.

WARNING:

  To avoid the risk of electric shock or burns, always connect the safety (or earth) ground before making any other connections.  

WARNING:

  To reduce the risk of fire, electrical shock, or physical injury it is strongly recommended to fuse the voltage measurement inputs.  Be sure to locate fuses as close to the 

source as possible. 

WARNING:

  Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards.   

WARNING:

  In the event of repeated failure, do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse.  

WARNING:

  Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install, adjust, operate, or service this 

equipment.  Read and understand this manual and other applicable manuals in their entirety before proceeding.  Failure to observe this precaution could result in severe bodily injury 
or loss of life. 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 

1.  This device may not cause harmful interference. 

2.  This device must accept any interference received, including interference that may cause undesired operation.  

Summary of Contents for HE-XT103

Page 1: ...test product manuals omegamanual info User sGuide Shop online at MADE IN HE XT103 12 Digital DC Inputs 12 Digital Outputs 2 Analog Inputs Medium Resolution HE XT104 24 Digital DC Inputs 16 Digital Out...

Page 2: ...ged by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 0 800...

Page 3: ...Current Mode 100 Voltage Mode 500 k Required Power Steady State 130 mA 24 VDC Required Power Inrush 30 A for 1 ms 24 VDC Nominal Resolution AI full scale Max Over Current 10 Bits 32 000 counts 35 mA P...

Page 4: ...captures program loading and recipes Horner Part No HE MC1 Serial Communications MJ1 RS 232 RS 485 Use for Cscape programming and Application Defined Communications MJ2 RS 232 RS 485 Use for Applicati...

Page 5: ...SC1 Accumulator AI7 AI8 HSC2 Accumulator AI9 AI10 HSC3 Accumulator AI11 AI12 HSC4 Accumulator AQ1 AQ2 PWM1 Duty Cycle AQ3 AQ4 PWM2 Duty Cycle AQ5 AQ6 PWM Prescale AQ7 AQ8 PWM Period AQ9 to AQ14 Analog...

Page 6: ...RD Substitution of components may impair suitability for Class I Division 2 AVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE...

Page 7: ...se shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OME...

Page 8: ...r Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Ind...

Reviews: