background image

3

3

4

HB1701

Power source   

HB1701

Power

-2

-4

-

N2

+

changed in the rated scope, the circuit works at the voltage-stabilizing state. When 
the load exceeds the rated value or the output end is short circuit, the circuit loses 
voltage-stabilizing function and automatically changed into current-stabilizing state. 
If the load is lower than the rated value or is open circuit, the circuit will automatically
change into voltage-stabilizing state.          
When the circuit works at the current-stabilizing state, the current-stabilizing part is 
the protective circuit. When the circuit works at the voltage-stabilizing state, the 
voltage-stabilizing part takes the effect of voltage limiting. It is the ideal design with
 mutual protection. 
If R1=R2, the voltage of the in-phase input end of N4 is (V01+V02)/2, and the stable
output of adjusting V02 of N4 is (V01+V02)/2. V01=V02, and then the changing of 
secondary voltage tracking the main voltage will be realized. 

When the power source is set at the tracking working state, the two groups of 
voltage comparison amplifiers of the internal circuit can be connected as 
Diagram (2-2).   

 Main
 circuit

Secondary 
circuit

(Diagram 22 tracking connection)

Using instruction

I. Function instruction for panel control 

 Power switch: POWER
 Voltage-adjusting knob: Classified into left (main) and right (secondary) 

     knobs that adjust respective voltage-stabilizing output separately. 

 Current-adjusting knob: Classified into two knobs that adjust respective 

     current-stabilizing output separately.

 Index gauge V/A: Indicate the left and right voltage or current value 

     separately.    

 Voltage/current exchange button: The current value will be indicated by 

     pressing the button. The voltage value will be indicated without pressing 
     the button. 

 Tracking/independent button: It is at the  independent  working state 

     without pressing the button and at the  tracking  working state by pressing 
     it. 

II. Output working mode
1. Independent working mode

    Tracking/independent button, if setting  independent , two groups of independent
     power sources will obtain. See Diagram 3-1.
2. Tracking working mode
    Tracking/independent button, if setting  tracking , short connect output end

 +

    of  the main circuit and

of the secondary circuit, and then a group of power 

    source  with the same output voltage value and opposite pole will obtain. See 
    Diagram 3-2 for connecting. 

HB1701

Power source   

Main 

circuit

Secondary

 

circuit

 

Load

Load

Load

Main 

circuit

Secondary

 

circuit

 

Diagram 3-1 independent state 

Diagram 3-2 tracking state

3. Parallel working mode (using for extending the current)
    Tracking/independent button, if setting  independent , two circuits of output 
    voltage should be adjusted to the using value. See Diagram 3-3 for connecting.
4. Series working mode (using for extending the voltage)
    Tracking/independent button, if setting  independent , two circuits of output preset 
    current will be more than the using current. See Diagram 3-4 for connecting.
5. Adjust output voltage, open circuit on the output end. Adjust output current, short 
    circuit on the output end. 
6. Users can ground the power source or connect into electric potential of his own 
    system in accordance with the using environment condition and demand. See 
    Diagram 3-5.
There are four output ends in series or main and secondary tracking working. In 
principle, only one end can be grounded (chassis). 

HB1701

Power

Main 

circuit

Secondary

 

circuit

 

Main 

circuit

Secondary

 

circuit

 

Load

Load

HB1701

Power

Null line 
Earth wire 
Phase line

Main 
circuit

Secondary 
circuit 

Diagram 3-3 
parallel state

Diagram 3-4
 series state

Diagram 3-5 

OMEGA

 

DC

 

Stabilized

 

power

 

source

Reviews: