OPERATION

Changing Flow Meter Settings

Home Screen and General Navigation

The HOME Screen displays flow volume, direction of  the 

flow total and flow RATE along with status conditions such 

as Empty Pipe. Two buttons below the LCD display are used 

to access menu screens for viewing and changing meter 

setup parameters. 

These two buttons are light sensors which can detect 

when  a  finger  is  covering  them  and  activate  upon 

release. 

Only three button touch actions are needed to 

control navigation through the menus, settings changes 

and back to the home screen. 

1.2345678

   

   100

TOTAL

CU FT

X1000

RATE

GPM

T UNIT

R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL = GALLONS

PRESS       +       TO SET TOTAL

UNITS FOR DISPLAY

T UNIT R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL:

        PRESS      TO CHANGE

GALLONS

FORWARD TOTAL

Making Selections

Once in the Menu System, move from tab to 

tab by tapping the right button.  (See the next 

page for details on the various available tabs.)

Select  the  parameter.

 In the screen for 

the highlighted tab you will see the current 

parameter value for that tab. Tapping the right 

button, move to the tab for the parameter you 

want to change. 

In this example, the first line indicates that the 

current unit for the TOTAL is GALLONS. The 

next two lines tell you what to do next. 

If you would like to change the TOTAL units, 

just perform the hold and tap sequence to 

bring up a screen to change the setting. 

Select a new setting.

 Select the new setting 

by scrolling through a list of selections as in 

the screen illustration below by tapping the 

left  button to find a different TOTAL unit. 

Accept  changes.

 To accept any changes 

you have made, perform  the hold and tap 

sequence. 

When finished making changes. 

When you 

are finished making changes, move to the EXIT 

tab using the right button.

To return to the HOME screen, perform the 

hold and tap sequence. 

TAP

TAP

1.2345678

100

TOTAL

CU FT

X1000

RATE

GPM

T UNIT

R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL = GALLONS

PRESS       +       TO SET TOTAL

UNITS FOR DISPLAY

T UNIT R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL:

        PRESS      TO CHANGE

GALLONS

FORWARD TOTAL

+

HOLD TAP

1.2345678

100

TOTAL

CU FT

X1000

RATE

GPM

T UNIT

R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL = GALLONS

PRESS       +       TO SET TOTAL

UNITS FOR DISPLAY

T UNIT R UNIT SET  P DAMP

SET  4 SET 20 SET F

EXIT

TOTAL:

        PRESS      TO CHANGE

GALLONS

FORWARD TOTAL

TAP

+

HOLD TAP

TAP

+

HOLD TAP

HORIZONTAL SCROLLING:

Tap right button to scroll horizontally through 

menu tabs or move horizontally within a tab 

dialog when applicable.

SELECT:

 

Tap left button to change a highlighted item 

within a tab dialog.

ENTER/EXIT: 

Hold left button while tapping right button 

once to enter or exit a tab dialog or to navigate 

between the HOME and  other menu screens.

 

Changing Total Direction/Resetting Batch 

Totalizers

On the Main screen, hold   and tap  5 times 

to scroll through the total direction options.  

Release   to select a total direction. 
Once BATCH FORWARD or BATCH REVERSE is 

selcted, tap   four times to reset batch totalizer.

Entering Menu System

To enter the Menu System perform the hold 

and tap sequence. The Passcode entry screen 

will display. The default passcode is 000000. If 

a different passcode has previously been set, 

use the   and   to enter that passcode. 

In either case, hold and tap again to move 

into the menu system. (

If you enter the wrong 

passcode, hold  and tap  again to  return  to  the 

previous screen. See page 21 for information on 

how to change a passcode.)

TAP

TAP

+

HOLD TAP

000000

ENTER PASSCODE

PRESS     AND    TO CHANGE

+

HOLD TAP

+

HOLD

TAP

Summary of Contents for FMG490 Series

Page 1: ...e mail info omega com For latest product manuals omega com en us pdf manuals XXXXXX Xxxxx Xxxxxxxx Shop online at omega com User sGuide TM FMG490 SERIES Municipal Industrial Magmeter...

Page 2: ...ns without notice omega com info omega com Servicing North America U S A Omega Engineering Inc 800 Connecticut Ave Suite 5N01 Norwalk CT 06854 Headquarters Toll Free 1 800 826 6342 USA Canada only Cus...

Page 3: ...onfiguration Sourcing Mode Output Application Page 16 Sinking Mode Output Application Page 16 Analog 4 20mA Current Loop Output Application Page 16 Cable Shield Page 17 Pulse Output Page 17 Analog 4 2...

Page 4: ...t flow batch forward flow and batch reverse flow Batch totals can be reset Built in data logging is available as an option for secure flow logging Scaled pulse output is standard and one additional ou...

Page 5: ...gal Cubic Meters Cubic Meters x 1000 Cubic Feet Cubic Feet x 1000 Second Foot Day Million Cubic Feet Acre Feet Acre Inches Imperial Gallons Imperial Gallons x 1000 Million Imperial Gallons Fluid Ounce...

Page 6: ...ter Size L H T ID Shipping Weight inch mm inch mm inch mm inch mm lbs Kg 3 12 25 311 7 08 179 8 68 17 25 2 6 66 04 40 18 4 10 12 257 8 3 211 62 15 7 3 12 79 43 19 5 6 12 09 307 9 1 231 69 17 5 5 05 12...

Page 7: ...0 6 8 10 FMG490 Accuracy Pipe Size Inches in diameter 3 4 6 8 10 12 Max Flow Rate Gallons Minute 723 1285 2891 5140 8031 11565 Cut off min Flow Rate Gallons Minute 3 62 6 43 14 46 25 70 40 15 57 82 M...

Page 8: ...ing Flow Propeller Meter Partially Open Butterfly Valve 1X 1X 1X 1X Swirling Flow NOTE These configurations are to be used as general guidelines and do not cover every possible installation A combinat...

Page 9: ...ent on the electrodes can affect accuracy Recommended Improved accuracy results from unimpeded electrodes Electrode moved from top by rotating meter Intermittent air bubbles miss electrode Electrodes...

Page 10: ...er ANSI 150 lb flanges See table on page 11 for flange bolt tightening torque specifications Calibration The FMG490 meters are factory calibrated and will not require any form of field calibration Che...

Page 11: ...tem must be grounded to meet national and local electrical safety codes Failure to do so can result in electrocution Equalization Lug Meter Flange Pipe Flange Gasket Pipe Flange Flange Plate Lockwashe...

Page 12: ...e 1 Cable Gland Opening and Sealing The display is available in either DC or AC versions DC version AC Version If the meter is configured with AC power one of the additional Power Output cable ports m...

Page 13: ...latory agency approval If installed outdoors or less than 33ft 10m from a utility power service entrance AC power should be supplied via a properly grounded surge suppression device 10 Remove the plug...

Page 14: ...sensor cable inside the internal strain relief clip and tighten the cable gland sealing nut securely torque strain relief sealing gland dome nut to 22 in lbs A lose nut could cause moisture ingress an...

Page 15: ...ange R Remote B pn11 Blue R Remote A pn12 Black C1 DC pn14 Red C1 DC pn15 WARNING BACKUP BATTERIES ARE NOT INTENDED AS A PRIMARY POWER SOURCE OF A MAINS DC or AC CONFIGURED METER Remove the 3 screws h...

Page 16: ...D5L D6L RED C1 BLACK C1 BLUE R ORNG R BLACK R RED R BLUE C1 ORNG C1 GREEN C1 WHITE C1 A5N A6N RED INT BLACK INT BLUE R ORNG R BLACK R RED R GREEN C1 WHITE C1 A5L A6L RED INT BLACK INT BLUE R ORNG R BL...

Page 17: ...pplication Sinking Mode Recommended for Rin 30k Analog 4 20mA Current Loop Output Application Minimum resistor value is 100 x Vs ohms Higher resistances maybe used depending on frequency and cable len...

Page 18: ...units totaled per pulse all sizes of meters can be configured with the same SETP values For example if your rate is chosen as gallons per minute GPM the table below applies If your rate is different...

Page 19: ...perform the hold and tap sequence When finished making changes When you are finished making changes move to the EXIT tab using the right button To return to the HOME screen perform the hold and tap s...

Page 20: ...g average SET 4 View or change flow rate corresponding to 4mA SET 20 View or change flow rate corresponding to 20mA EXIT Return to HOME SCREEN or enter SUBMENU T UNIT R UNIT SET P DAMP SET 4 SET 20 SE...

Page 21: ...the number of samples for rolling average of pulse output TEST TEST allows the user to initiate a fully functional artificial flow rate for the purpose of testing other connected equipment When TEST i...

Page 22: ...correct but pulse frequency output is low erratic or absent Wiring incorrect Compare wiring with appropriate wiring recommendations External device input impedance too low Use sourcing rather than sin...

Page 23: ...nation by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but no...

Page 24: ...as Mass Flowmeters Flow Computers Air Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controll...

Reviews: