OPERATION

To ‘wake up’ a battery powered meter, you may need to 

hold the up arrow for 5 seconds and release. If the meter 

does not wake up on the first attempt, repeat the 5 second 

hold.

The

 

meter  can  come  configured  with  one  7.2V  ‘D’  size 

replaceable  battery  pack.    In  this  configuration, 

the 

only  option/output  is  the  scaled  pulse  output  which 

comes standard.  The scaled output for the  battery 

powered option has a maximum pulse rate of 150 pulses/

second.  Be sure to set your P value such that the meter will 

function properly over the flow range in your application.  

The sample  rate of the meter is user selectable through 

the SAMP tab in the meter’s sub-menu.  Sample periods 

of  1/5, 1/3, 1, 3, 5, 15, 30, and 60 seconds can be selected.  

(A sample period of 5 seconds—5 year battery life—is the 

default.)
Larger sample periods will yield longer battery life but 

slower response time.

 

Care must be taken to select a 

sample period that is suitable for your application.  See the 

table below for the expected battery life as a function of 

sample period.

DAMP Settings for Battery Units

If SAMP (sample period) is set to less than one second, the 

DAMP value represents the number of seconds (plus one) 

used in the rolling average for the display. For example, if 

DAMP is set to four, then when the meter begins to show 

a  flow rate,  the  rate  displayed  is  the  average  of  all  the 

readings taken in seconds

 one through five (4 plus 1). 

If SAMP (sample period) is set to one second or longer, 

the DAMP value represents the number of sample periods 

(plus one) used in the rolling average for the display. For 

example, if SAMP is set at three seconds and DAMP is set to 

four, then when the meter begins to show a flow rate, the 

rate displayed is the average of samples

 one through five 

(4 plus 1). Note that depending on the settings selected, 

Battery Life/Sample Period

For battery (BX) powered meters only.

Sensor sample period(s)

(Seconds)

Expected battery life* 

1/5 (0.2)

7 months

1/3 (0.33) 

1 year

1

2.25 years

3

4 years

5

5 years

15

6 years

30

6.25 years

60

6.5 years

*Based on 75% battery capacity at room temperature with

no option cards installed.

NOTE: If a large percentage of the meter’s life will be spent 

below 0.5 meters/second and above cutoff, battery life will 

be reduced.

Battery Powered Units

A power indicator is displayed in the lower left of the main 

display window.
Any meter powered from an external power source will 

display a power plug icon when running on external power. 

If the connection to external power is lost, the meter will 

switch to the backup battery and the power icon will switch 

to a battery symbol.

OK

 on the battery indicator means battery voltage is above 

6.4 volts.

LO

 on the battery indicator means the battery is low and 

should be replaced soon.

OK

LO

P

OK

LO

Being powered by external 

DC or AC
Being powered by battery - 

voltage is sufficient
Being powered by battery - 

voltage is low

1.2345678

   

   100

TOTAL

CU FT

X1000

RATE

GPM

T UNIT

R UNIT SET  P DAMP

SET  4

SET  4

SET 20

SET 20

SET  F

SET  F

EXIT

TOTAL = GALLONS

PRESS       +       TO SET TOTAL

UNITS FOR DISPLAY

T UNIT R UNIT SET  P DAMP

SET  4

SET  4

SET 20

SET 20

SET  F

SET  F

EXIT

TOTAL:

        PRESS      TO CHANGE

GALLONS

0.0000000

     SET    ID

TOTAL

ACRE

FEET

RATE

GPM

OK

FORWARD TOTAL

FORWARD TOTAL

P

Power Indicators

If display reads,  ‘BATT END’

 replace battery 

immediately.

BATTERY LIFE WITH MODBUS

®

 OPTION! 

IN THIS CONFIGURATION THE METER COMES STANDARD 

WITH PULSE OUTPUT. WHEN ORDERED WITH THE 

MODBUS

®

 OUTPUT OPTION, BATTERY LIFE WILL BE 

REDUCED TO 1 YEAR, OR GREATER, BASED ON USAGE. 

REDUCE POLLING FREQUENCY AND MINIMIZE DATA 

COLLECTED IN ORDER TO MAXIMIZE BATTERY LIFE.

it may take up to a minute for the displayed rate to take 

full advantage of the DAMP filter. When starting with an 

EMPTY PIPE it may take at least 30 seconds to register 

any flow.

Summary of Contents for FMG470 Series

Page 1: ...PROUDLY MADE IN THE USA C e rtified Compa n y ISO ISO 9001 FMG470 Series Municip Municipal Industrial Magmet al Industrial Magmeter er...

Page 2: ...notice omega com info omega com Servicing North America U S A Omega Engineering Inc 800 Connecticut Ave Suite 5N01 Norwalk CT 06854 Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Serv...

Page 3: ...alog 4 20mA Current Loop Output Application Page 12 Cable Shield Page 13 Pulse Output Page 13 Analog 4 20mA Output Page 14 Modbus Output Page 14 Operation Changing Flow Meter Settings Home Screen and...

Page 4: ...nd total units and pulse scaling can be set via the front panel touch key pad by the user Bidirectional flow reading is standard with totals available in forward reverse net flow batch forward flow an...

Page 5: ...llion Gallons Liters Kilo Liters Mega Liters Barrels 42 gal Cubic Meters Cubic Meters x 1000 Cubic Feet Cubic Feet x 100 Cubic Feet x 1000 Second Foot Day Million Cubic Feet Acre Feet Acre Inches Impe...

Page 6: ...8 1 206 62 15 7 2 68 68 30 13 6 4 10 12 257 8 3 211 62 15 7 3 12 79 33 15 6 12 09 307 9 1 231 69 17 5 5 05 128 49 22 8 14 14 359 10 1 257 69 17 5 6 44 164 70 32 10 18 08 459 11 2 284 69 17 5 8 61 219...

Page 7: ...off min Flow Rate Gallons Minute 1 61 3 61 6 43 14 46 25 70 40 15 57 82 Max Flow Rate Liters Second 20 25 46 81 182 324 507 730 Cut off min Flow Rate Liters Second 0 13 0 23 0 41 0 91 1 62 2 54 3 65 M...

Page 8: ...ter Partially Open Butterfly Valve 1X 1X 1X 1X Swirling Flow INSTALLATION NOTE These configurations are to be used as general guidelines and do not cover every possible installation A combination of t...

Page 9: ...er Intermittent air bubbles miss electrode Electrodes free from sediment build up Not Ideal Allows air pockets to form at meter Recommended Keep pipe full at meter for accuracy Not Ideal Post valve ca...

Page 10: ...lange bolt tightening torque specifications Calibration The FMG470 Series is factory calibrated before shipping The frequency of recalibration will depend on the needs of each application and local re...

Page 11: ...nstalled in a plastic piping system or when externally powered the piping system must be grounded to meet national and local electrical safety codes Failure to do so can result in electrocution Equali...

Page 12: ...POWER SOURCE OUTPUT S BXX BATTERY POWER PULSE SCALED BXS BATTERY POWER PULSE SCALED MODBUS D1X D2X DC POWER PULSE SCALED D1L D2L DC POWER PULSE SCALED AND 4 20mA D1S D2S DC POWER PULSE SCALED AND MOD...

Page 13: ...alog 4 20mA Current Loop Output Application Minimum resistor value is 100 x Vs ohms Higher resistances maybe used depending on frequency and cable length Longer cables and high frequencies require low...

Page 14: ...gallons per minute GPM the table below applies Pulse Units The units of measure of SETP are independently selectable and are not tied to rate or total Upon change of the SETP unit the pulse output may...

Page 15: ...Modbus Serial Communication Configuration factory configured These connections provide a half duplex isolated RS485 serial communications port using the Modbus messaging protocol The TXD connection is...

Page 16: ...making changes When you are finished making changes move to the EXIT tab using the right button To return to the HOME screen perform the hold and tap sequence TAP TAP 1 2345678 100 TOTAL CU FT X1000 R...

Page 17: ...olling average T UNIT R UNIT SET P DAMP SET 4 SET 20 SET F EXIT TOTAL GALLONS PRESS TO SET TOTAL UNITS FOR DISPLAY T UNIT R UNIT SET P DAMP SET 4 SET 20 SET F EXIT FLOW RATE GALLONS MIN PRESS TO SET R...

Page 18: ...return to the THIRD MENU screen Tab to EXIT and then hold and tap to return to the SUBMENU To change the number of decimal places in the total To set the decimal point hold and tap on SETD and then us...

Page 19: ...nding on the settings selected Battery Life Sample Period For battery BX powered meters only Sensor sample period s Seconds Expected battery life 1 5 0 2 7 months 1 3 0 33 1 year 1 2 25 years 3 4 year...

Page 20: ...pulse frequency output is low erratic or absent Wiring incorrect Compare wiring with appropriate wiring recommendations External device input impedance too low Use sourcing rather than sinking interfa...

Page 21: ...nation by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but no...

Page 22: ...Flow Computers Air Velocity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Si...

Reviews: