  9. Install the back coverplate. Make sure

the O-ring is securely seated and no
wires are pinched.

10. Connect to the user interface device ac-

cording to manufacturer’s instructions.

11. Refer to the etched K-factor on the tur-

bine. See Turbine Manual for location
of K-factor.

NOTE:  Please remember to supply a 820

ohm (minimum) Pull Up Resistor if the
interface device does not have one. Ref-
erence illustration above as necessary.

Frequency Range: 0 to 750 Hz

Housing Material: Nylon 6/6

Strain Relief:

Hubble-PG7

Coverplate  Thread: Female 1/2-20 UNF-2B

Cable:

Belden 9363

Std. Cable Length: 10 ft. (3m)

Temperature:

+14

°

 to +140

°

F

(–10

°

 to +60

°

C)

Open Collector
Currect Sinking Output

Applied Voltage:

0 to 60 Volts DC

Connection:

Two Wire

Allowable Current: Up to 100 mA

Output:

Square Wave Pulse.
Amplitude same as
supplied voltage.

NOTE:  Display electronics, which work in

conjunction with this module, continue
to be powered with batteries.

TECHNICAL SPECIFICATIONS

The Pulse Output Module with a standard FTB790

Series Turbine Meter with Display Electronics

which are sold seperately.

Dimensions (FLSC790-P)

0.25 in. (.64 cm)

0.8 in.

(2.0 cm)

3.25 in. (8.26 cm)

1.63 in.

(4.14 cm)

1.0 in.

(2.54 cm)

2.0 in.

(5.1 cm)

Summary of Contents for FLSC790-P

Page 1: ...http www omega com e mail info omega com FLSC790 P Pulse Output Module For use with FTB790 Series Turbine Meters with Display Electronics User sGuide omega com omega com...

Page 2: ...0800 1 66342 e mail czech omega com France 9 rue Denis Papin 78190 Trappes Tel 33 130 621 400 FAX 33 130 699 120 Toll Free in France 0800 4 06342 e mail france omega com Germany Austria Daimlerstrasse...

Page 3: ...you are installing more than one PulseAccess Module at a time take care to keep the proper electronics paired with the original turbine 1 3 The Pulse Access Module connects to a 10 pin connector locat...

Page 4: ...in Relief Hubble PG7 Coverplate Thread Female 1 2 20 UNF 2B Cable Belden 9363 Std Cable Length 10 ft 3m Temperature 14 to 140 F 10 to 60 C Open Collector Currect Sinking Output Applied Voltage 0 to 60...

Page 5: ...itches for 12 4 VDC OUT No connection is made to EXCITATION OUT the white wire is pulled up to the 12 4 VDC excitation inside of the DPF700 Wiring to DPF70 Series Panel Meter DPF75 DPF76 DPF78 For con...

Page 6: ...4 NOTES...

Page 7: ...ase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used...

Page 8: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Reviews: