REASSEMBLY PROCEDURE

(Refer to parts diagram.)

1. Use the reverse of steps 1 through 6 of the disassembly

Procedure to reassemble the meter.

2. When replacing the packing seats in the flowmeter body

be sure the packing inserts are approximately 1/16" above
the top of the packing seat. Also be certain the tube seats
firmly on the packing seats and does not overlap onto the
end block.

3. The seal spindle serves to radially compress the tube seat

gasket and exert a uniform pressure on the metering tube
to prevent any possibility of leakage. Do not overtighten
the seal spindle.

4. After the flowmeter has been reassembled, it is important

that it be hydrostatically tested at a liquid pressure of 300
psi at room temperature.

CAUTION

Hydrostatic testing should be performed only by trained
and qualified personnel or serious damage could result.

ITEM

DESCRIPTION

PART NUMBER

MATERIAL

1

Metering Tube Assembly, Metering Tube (Std. or

per S/N 

Standard, or Direct Etched

Direct Etched) 316 Stainless Steel Float,
Neoprene Packing, Stainless Steel Spring Stops

2

Float

per S/N

Stainless Steel

3

Spring Float Stops

per S/N

Stainless Steel

4

End Fitting (Outlet)

A-325-G-001

Brass or Stainless Steel

*5

End Fitting (Inlet - Use Without Valve)

A-325-J-006

Brass or Stainless Steel

End Fitting (Inlet - Use With Valve)

A-325-H-002

Brass or Stainless Steel

6

Jack-Screw Assembly

S-817-Z-009

Brass or Stainless Steel

7

Jack-Screw Nut

A-618-J-005

Brass or Stainless Steel

8

O-Ring

F-375-B-905

Buna-N, Kel-F, Viton

9

O-Ring (major)

F-375-B -211

Buna-N, Kel-F, Viton

10

O-Ring (minor)

F-375-B-010

Buna-N, Kel-F, Viton

11

Inlet and Outlet Packing

A-589-B-043

Neoprene or Teflon

12

Window Shield (2) with Screws

A-794-A-012-NOA

Clear Plexiglas

13

Sideplate (2) with Screws

A-614-A-008-FCG

Aluminum

14

Adapter (2) 3/8” NPT

A-014-C-023

Brass or Stainless Steel

15

O-Ring

F-375-B-908

Buna-N, Kel-F

16

Needle Valve Assembly

T-947-B-110

Brass or Stainless Steel

* End fitting only, valve not included. See item 16 when ordering valve.

WARNING     

Glass metering tubes are designed for operation up to the maximum operating pressures and temperatures as

specified herein. Due to the inherent brittle characteristics of glass and conditions beyond our control, tube breakage could
result below specified operating conditions. Possible glass tube breakage represents a potential hazard to operating personnel;
therefore, operator protection should be supplied where operating pressures may exceed 50 psig. A safety shield constructed of
1/2 inch acrylic plastic may be used or the glass tube meter may be replaced with an all metal (armored) meter.

PARTS LIST

When ordering parts, please specify: SERIAL NUMBER,
flowmeter Model Number, Part Number if available, and if
known, specify materials of construction.

7

14

8

4

15

12

6

6

6

13

11

9

2

14

13

15

5

1

31

16

47

32

12

29

27

28

30

FL-1200 Series Part Drawing