background image

CL1600 Programmer Software 

Overview 

The CL1600 Surface Probe Tester ships from the factor 

with a copy of the Omega Programmer software. This is 

an easy to use software package, especially written for 

the CL1600. Only on instrument can run this software in 

one computer at a time.
Program Installation 

It is advisable to have your IT Department install this 

software into your computer. Always back-up your 

system before attempting to install this or any other 

software package into your computer. Assuming you 

have backed up your computer files, run the install 

program. This program will run trouble free with 

Windows

®

 95, 98, ME, NT, 2000 

Main Display

Main Screen

1.  These are two analog gauges and corresponding 

digital display windows; one is red to indicate process 

temperature, the other is green to indicate set point 

temperature.

2. The graph tracks the set point and process values
3.  The change temperature wheel will allow rough 

temperature setting between 45 to 450°C. Below it 

there is a fine tune up and down arrow that allows 

for fine tune setting in increments of 0.1 degrees. 

To the right there is the FIND button. Pressing this 

button will start tracking the set temperature on the 

controller.

4.  The Preset Setpoint buttons allow you to change the 

setpoint temperature to pre-defined values ranging 

from 45 to 450°C.

5. The QUIT button to exit the application.

ARTWORK/PRODUCT ART/

 DWGS/START HERE ARROW

5

ARTWORK/PRODUCT ART/

 DWGS/START HERE ARROW

6

CL1600-120VAC

CL1600-240VAC

Surface Probe Tester

omega.com   [email protected]

®

Servicing North America:

U.S.A.:

 

OMEGA Engineering, Inc., One Omega Dr. 

 

P.O. Box 4047, Stamford, CT 06907-0047 USA 

 

 Toll-Free: 1-800-826-6342 (USA & Canada Only) 

Customer Service: 1-800-622-2378 (USA & Canada Only)  

Engineering Service: 1-800-872-9436 (USA & Canada Only) 

Tel: (203) 359-1660 

Fax: (203) 359-7700 

 

e-mail: [email protected]

For Other Locations Visit omega.com/worldwide

The information contained in this document is believed to be correct, but 

OMEGA accepts no liability for any errors it contains, and reserves the right to 

alter specifications without notice. 

WARNING: These products are not designed for use in, and should not be used  

for, human applications.

MQS4593/1213

Settings

Settings Screen

SOUND:  

Will allow audible indications while monitoring.  

Selections: ON, OFF
COM Port:  

Selects the communication port to be used while 

monitoring.  

Selections: COM1, COM2, COM3, or COM4 

Default: COM1
DECIMAL POINT:  

Selects the decimal point accuracy for the readouts.  

Selections: ONE, NONE 

Default: ONE
TEMPERATURE UNITS:  

Selects units of temperature to display on readouts.  

Selections: CELCIUS, FAHRENHEIT 

Default: CELCIUS
SKIP LOGO INTRODUCTION:  

Selecting this box will cancel the logo introduction when 

the program is activated from your desktop.
LOG TO FILE:  

Selecting this box will allow data login. This command 

is inactive at this time.
CHART TIME BASE:  

Allows user to set the horizontal time graph display. 

Selections: 1 minute, 10 minutes, or 1 hour
AUTOMATIC SCALING:  

Selecting this box will pre-select a vertical scale which 

varies according to temperature setting.  

Un-selecting this box, will allow user to set up values to 

zoom-in closer to the desired temperature range.

For complete product manual:  

www.omega.com/manuals/manualpdf/M4593.pdf

1

3

4

5

2

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects 

in materials and workmanship for a period of 

13 months

 from 

date of purchase. OMEGA’s WARRANTY adds an additional one (1) 

month grace period to the normal 

one (1) year product warranty

 

to cover handling and shipping time. This ensures that OMEGA’s 

customers receive maximum coverage on each product. 
If the unit malfunctions, it must be returned to the factory for 

evaluation. OMEGA’s Customer Service Department will issue an 

Authorized Return (AR) number immediately upon phone or written 

request. Upon examination by OMEGA, if the unit is found to be 

defective, it will be repaired or replaced at no charge. OMEGA’s 

WARRANTY does not apply to defects resulting from any action of 

the purchaser, including but not limited to mishandling, improper 

interfacing, operation outside of design limits, improper repair, 

or unauthorized modification. This WARRANTY is VOID if the unit 

shows evidence of having been tampered with or shows evidence of 

having been damaged as a result of excessive corrosion; or current, 

heat, moisture or vibration; improper specification; misapplication; 

misuse or other operating conditions outside of OMEGA’s control. 

Components in which wear is not warranted, include but are not 

limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various 

products. However, OMEGA neither assumes responsibility for 

any omissions or errors nor assumes liability for any damages 

that result from the use if its products in accordance with 

information provided by OMEGA, either verbal or written. 

OMEGA warrants only that the parts manufactured by the 

company will be as specified and free of defects. OMEGA 

MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF 

ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT 

THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING 

ANY WARRANTY OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. 

LIMITATION OF LIABILITY: The remedies of purchaser set forth 

herein are exclusive, and the total liability of OMEGA with 

respect to this order, whether based on contract, warranty, 

negligence, indemnification, strict liability or otherwise, 

shall not exceed the purchase price of the component upon 

which liability is based. In no event shall OMEGA be liable for 

consequential, incidental or special damages. 

CONDITIONS: Equipment sold by OMEGA is not intended to be used, 

nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), 

used in or with any nuclear installation or activity; or (2) in medical 

applications or used on humans. Should any Product(s) be used in or 

with any nuclear installation or activity, medical application, used on 

humans, or misused in any way, OMEGA assumes no responsibility 

as set forth in our basic WARRANTY/DISCLAIMER language, and, 

additionally, purchaser will indemnify OMEGA and hold OMEGA 

harmless from any liability or damage whatsoever arising out of the use 

of the Product(s) in such a manner.

RETURN REQUESTS/INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA 

Customer Service Department.  BEFORE RETURNING ANY 

PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN 

AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER 

SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING 

DELAYS). The assigned AR number should then be marked on the 

outside of the return package and on any correspondence.
FOR 

WARRANTY

 RETURNS, 

please have the following 

information available BEFORE 

contacting OMEGA:
1. Purchase Order number under 

  which the product was  

 PURCHASED, 

2. Model and serial number of    

  the product under warranty, and 

3. Repair instructions and/or    

  specific problems relative to 

  the product.

FOR 

NON-WARRANTY

 REPAIRS, 

consult OMEGA for current repair 

charges. Have the following 

information available BEFORE 

contacting OMEGA:
1.  Purchase Order number to    

  cover the COST of the repair or  

 calibration,

2.  Model and serial number of the 

  product, and 

3.   Repair instructions and/or specific 

problems relative to the product.

OMEGA’s policy is to make running changes, not model changes, 

whenever an improvement is possible. This affords our customers 

the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2013 OMEGA ENGINEERING, INC. All rights reserved.  

This document may not be copied, photocopied, reproduced, 

translated, or reduced to any electronic medium or machine-readable 

form, in whole or in part, without the prior written consent of OMEGA 

ENGINEERING, INC.

Reviews: