Omega BB700 Series User Manual Download Page 7

Section 2 - Installation

2.1 

Unpacking and Inspection

Remove the packing list and verify that you have received all your equipment. 

If you have any questions about the shipment, please call our Customer Service 

Department at
1-800-622-2378 or 203-359-1660. We can also be reached on the Internet at 

www.omega.com 

e-mail: [email protected]
When you receive the shipment, inspect the container and equipment for any 

signs of damage. Note any evidence of rough handling in transit. Immediately 

report any damage to the shipping agent.

The carrier will not honor any damage claims unless all shipping material is saved for inspection. 

After examining and removing contents, save packing material and carton in  

the event reshipment is necessary.

The following items are supplied in the box:

Item: 

 

OMEGA Part Number:

BB705 Blackbody Calibration Source 

BB705 or BB705-230

User Manual 

M-3638

Calibration Certificate 

CAL-3  (3 DATA  

 

 POINTS)

Power Cord 

200-0028 (Domestic), 

 

200-0107 (International)

2.2 Mounting

Mount the unit on a bench, table top or shelf in a horizontal position and operate 

at least ten inches from any air obstructions to the fan, front panel, rear panel, 

sides and top of the unit, in an ambient environment between the specified 0 to 

35°C (32 to 95°F).

2.3 

Ambient Temperature

The target cavity of the BB705 can achieve any temperature within the 

specified temperature range when being operated in normal specified ambient 

temperature environments. The maximum specified target plate temperature of 

1046°C (1915°F) can be achieved over the entire specified ambient temperature 

range of 0 to 35°C (32 to 95°F).

Installation

2

2-1

NOTE:

Summary of Contents for BB700 Series

Page 1: ...latest product manuals www omegamanual info BB705 Very High Temperature Laboratory Blackbody Calibration Source Shop online at omega com User sGuide TM This datasheet has been downloaded from http www...

Page 2: ...pecifications without notice omega com info omega com Servicing North America U S A Omega Engineering Inc Headquarters Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Cana...

Page 3: ...4 Controller Settings 3 5 3 4 1 Changing the Temperature Setpoint 3 5 3 4 2 Changing the Controller Parameter Settings 3 6 3 5 Temperature Reference Meter Settings 3 7 3 6 Target Cavity Temperature T...

Page 4: ...e 3 3 5 Rear Panel 3 4 6 Controller Default Parameters 3 6 7 Controller Programming Procedures 3 7 8 Approximate Target Plate Temperature Transition Times 3 8 9 Connecting a PC to the BB705 s Controll...

Page 5: ...t this unit to a non grounded non polarized outlet or power source This unit is intended for indoor use only Avoid exposure to any moisture or rain Do not connect the serial ports to equipment with ex...

Page 6: ...The calibration source with built in PID digital controller maintains an accuracy of 0 25 of reading 1 C The cavity has a 44 5 mm 1 75 diameter aperture with an emissivity of 0 99 and can be set to a...

Page 7: ...reshipment is necessary The following items are supplied in the box Item OMEGA Part Number BB705 Blackbody Calibration Source BB705 or BB705 230 User Manual M 3638 Calibration Certificate CAL 3 3 DATA...

Page 8: ...0 VAC 50 60 Hz Models On 230 VAC 50 60Hz models an International style power cord with the proper color code and approvals is provided with stripped wire ends for connection to the proper connector us...

Page 9: ...3 3 1 C A U T I O N CAVITY MAY B E H O T 1000C 1000 00C 1000C SETPTS MAX DEV MENU TEMPERATURE REFERENCE METER TEMPERATURE CONTROLLER SET VARIABLE PROCESS VARIABLE CAVITY APERTURE APERTURE PLATE POWER...

Page 10: ...is used to set the setpoint temperature and change engineering units Temperature Reference Meter The temperature reference meter displays the cavity temperature with high precision See Section 3 5 for...

Page 11: ...ronment only Never operate the unit outside or around children Nothing should come in contact with the heater cavity aperture or aperture plate Even when the unit is off Never unplug the unit while it...

Page 12: ...E METER CAUTION FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE REPLACE WITH ONLY THE SAME TYPE RATING AND SIZE OF FUSE DISCONNECT POWER FROM SOURCE BEFORE CHANGING FUSE INSTALLATION CATEGORY II 208...

Page 13: ...t temperature of the target plate Setpoint Temperature This field displays the desired target plate temperature Once the target plate reaches this desired temperature both displays will read the same...

Page 14: ...hrough LED indicators An indicator may be lit continuously blink or shut off entirely to indicate that the process is on being pulsed or off respectively 3 4 2 Changing the Controller Parameter Settin...

Page 15: ...ress the MENU key until the display reads RDG CNF 2 Press the MIN key until the display reads RDG 5 3 Set this parameter as desired using the MAX key 0 C 1 F 2 K 4 Press MENU to store the settings 5 P...

Page 16: ...to another First determine the current heater cavity temperature and go to the corresponding row Now decide the new heater cavity temperature and go to the appropriate column Note that there are X s a...

Page 17: ...ers should be viewed or queried from the controller directly It is highly recommended that baud rate for the controller be modified on the controller directly Note that both the BB705 and the computer...

Page 18: ...case R To read a parameter from the controller M To temporarily modify a controller parameter lost upon shutdown E To modify a controller param in non volatile mem saved even after shutdown parameter...

Page 19: ...ing soot from heater cavity be sure to wear protective goggles NEVER REMOVE SOOT FROM A HOT OR WARM CAVITY Be sure unit has cooled to room temperature and is disconnected from power source before vacu...

Page 20: ...ontrol Sensor Platinum Thermocouples Accuracy 1 C 0 25 rdg 1 8 F 0 25 rdg Ref Meter Display Accuracy 0 06 C over entire range Resolution 0 01 on temperature reference meter Overall System Stability 0...

Page 21: ...ler display shows Error a Unit requires service contact our and the target plate will not get customer service department hot or cold 4 Target plate temperature will a Verify that the controller is se...

Page 22: ...e ratio of energy emitted by a surface to the energy emitted by a blackbody at the same temperature IEC International Electrotechnical Commission Infrared IR A range of the electromagnetic spectrum ex...

Page 23: ...ource Calibration Range 32 to 400 C 90 to 752 F Accuracy 1 4 C 2 5 F Emissivity 0 95 Ambient Temp 0 to 40 C 32 to 104 F Cavity Size 28 6 mm 1 125 in Power 115 230V 50 60 Hz 175W BB704 4 Target Plate B...

Page 24: ...NOTES BB705 Very High Temperature Laboratory Blackbody Calibration Source 9 2...

Page 25: ...A if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to m...

Page 26: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...