background image

Thank you for purchasing

Omega Air Charger compressor

for PCPand carbon fiber tank filling.

Rapidly fill tank sizes from 6 cubic feet to 120 cubic feet . Aircraft machined aluminum is used extensively for internal compo-
nents, increasing strength and portability. Air-water separation with manual water release comes standard on all units. Shock-
resistant pressure gauges with automatic shut-off prevents over-filling .

In addition, all Omega Air Charger compressors use Royal Purple radiator coolants to reduce operating temperatures. The com-
pressor comes with a pre-mixed solution of Purple Ice radiator coolant and anti-freeze .Add purified water to the radiator prior
to initial start-up and operation of the compressor. This special mixture maximizes the radiator's cooling efficiency, helping to
increase heat exchange by upwards of 30%.

Only the highest quality Bio-based food grade lubricants from Renewable Lubricants are used in the crankshaft and multi-stage
high pressure piston chambers. This protects the PCP air tank's inner surface from oxidation while having excellent adhesion/
cohesion properties. Independent control of the compressor motor allows the radiator to continue to function while the motor
is not running ensuring and optimizing chamber cool down when extended filling is required.

OmegaAir Charger compressors come with thenecessary sealsandinstructions,giving theend-user total control ofbasic
maintenance for a trouble free life of the compressor.

All of these features make the Air Charger from Omega one of the most user-friendly and economical high PSI compressors in
the market today, providing years of continued service when properly used and maintained.

Compressor Operation and initial start

up Procedure:

Please read directions carefullyand follow oper-

ating procedures before each use.

Pour the 2 bottles of ICE and coolant (supplied in your kit) in the water tank and fill the rest of the way
with water. Approximately 1/2 inch below water flume.

Locate the grease port on top of the compressor and remove the shipping screw. Replace shipping screw
with the green extra volume grease head, hand tighten. 1 click (1/3 turn) every 6 hrs of compressor run-
ning.

The compressor gauge has 2 needles, push red knob in and move both needles to your desired PSI.

Locate power cord inside the box and insert cord into the compressor power socket. Make sure fan and
water pump are operating before pushing the green start switch.

Connect the air tank to the high-pressure fill hose using a 1/8 inch quick-connect adaptor, making sure the
connection is tightened firmly

After all preliminary "START-UP" procedures have been completed, push the green button to start air
compression and tank filling. The compressor will run until the desired PSI has been achieved. Once the
compressor shuts off, close the air tank and bleed out the excess air using the release valve near the
bottom of the compressor. Let radiator run for another 5 minutes in order to cool the piston chamber
completely. Do not switch off the entire compressor until this cool-off period has elapsed. Be sure to re-
lease all compressed air from the hose before removing the adaptor from the gun or tank

.

Do not fill air tanks above 4500 psi, as the burst disc is set to 4800 psi. If the burst disc bursts, there are
spares discs which can be easily replaced.

The compressor can run continuously for a maximum of 8 hours.

2

Reviews: