1.

 Ignition off, unplug the compressor and  
 connect to the compressor. 

3. 

 Connect to the battery. 

5.

 Connect a 

manifold gauge

 or 

charging machine

. (optional) 

6.

 Start the engine – idle at app. 1000-1500 RPM. 

7.

 Change the efficiency levels 0-100% with the +/- buttons (wait 10 s between steps) 
 Note the temperature and pressure changes. 
 If the diodes OL or OC illuminates – change the compressor. 

When you increase the efficiency (+) the following changes; 

High pressure side

  

Low pressure side 

Efficiency CLT1

 Low pressure*   Outlet temperature* 

Maximum 

 1,6 +/- 0,5 bar   0°C +/- 3° 

Minimum 

 3 +/- 0,7 bar 

 10°C +/-3° 

* Orientation levels – varies between manufacturer, model and ambient temperature 

2.

Connect the disconnected connector with  

 the simulator – prevents error code generation. 

4.

Apply a temperature sensor in the middle 

 outlet and put the fan on max. 

The temperature decreases 