MAInTenAnCe

Important:

 Use only good grade hydraulic jack oil. Avoid mixing different types of fluid and NEVER use brake fluid, 

turbine oil, transmission fluid, motor oil or glycerin. Improper fluid can cause premature failure of the jack and the 

potential for sudden and immediate loss of load. We recommend Mobil DTE 13M or equivalent.

Adding/ Changing Oil

For best performance and longest life, replace the complete fluid supply at least once per year.
1. With saddle fully lowered remove cover plate, then oil filler plug.

2. Lay jack on its side and drain fluid into a suitable container.

 

note:

 Dispose of hydraulic fluid in accordance with local regulations.

3. Set jack in its upright, level position.

4. Fill with oil. Proper oil level is just below the rim of the opening. Reinstall the oil filler screw.

  

Lubrication

A periodic coating of light lubricating oil to pivot points, axles and hinges will help to prevent rust and assure that 

wheels move freely and the pump functions smoothly. To help ensure trouble free operation, an inline air dryer and 

oiler is recommended.

Cleaning

Periodically check the ram for signs of rust or corrosion. Clean as needed and wipe with an oily cloth.

note:

 Never use sandpaper or abrasive material on ram surfaces! 

Storage

When not in use, store the jack with saddle fully lowered.

RePLACeMenT PARTS

(see pages 6 thru 9)

Not all components of the jack are replacement items, but are illustrated as a convenient reference of location and 

position in the assembly sequence. When ordering parts, please give the Model number, part number and parts 

description. Call or write for current pricing:  SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153, U.S.A.   

E-Mail: [email protected] Tel: (888) 332-6419  Fax: (816) 891-6599  Omega Website: http://www.omegalift.com

TROUBLeSHOOTInG 

Symptom

Possible Causes

Corrective Action

Jack will not lift load

• Release valve not tightly closed

• Load is too heavy

• Air supply inadequate

• Ensure release valve tightly closed

• Consider higher capacity jack

• Ensure adequate air supply

Jack will lift, but not maintain 

pressure

 

Release valve not tightly closed

• Hydraulic unit malfunction

 

Ensure release valve tightly closed

• Discontinue use, contact Omega 

technical service

Jack will not lower after unloading

• Reservoir overfilled

• Linkages binding

• Drain fluid to proper level

• Clean and lubricate moving parts 

Poor lift performance

• Fluid level low

 

Air trapped in system

• Ensure proper fluid level

 

With ram fully retracted, remove oil 

filler screw to let pressurized air 

escape. Reinstall oil filler screw

 Will not lift to full extension

• Fluid level low

• Ensure proper fluid level

Summary of Contents for 23221

Page 1: ...hazards Obey all safety messages that follow this symbol to avoid possible injury or death advertencia Leer comprender y seguir las instrucci nes antes de utilizar el aparato El manual de instrucci ne...

Page 2: ...operates smoothly Replace worn or damaged parts and assemblies with Omega authorized replacement parts only Bleeding Venting Trapped Air With the release valve in the OPEN position 3b and with ram fu...

Page 3: ...mL 23301 30 Ton 22 7 8 x 12 1 2 11 18 7 890 mL 23501 50 Ton 22 7 8 x 13 3 4 12 19 7 1650 mL 23991 100 Ton 26 x 15 3 4 12 18 1 8 6 1 8 2550 mL Figure 1 Typical Truck Jack Nomenclature 23222 shown Handl...

Page 4: ...ns Do not use this device to lift level lower support nor move a house mobile home travel trailer camper or any building structure Be alert and sober when using this product Do not operate under the i...

Page 5: ...abrasive material on ram surfaces Storage When not in use store the jack with saddle fully lowered REPLACEMENT PARTS see pages 6 thru 9 Not all components of the jack are replacement items but are il...

Page 6: ...els 23221 23222 Item Part No Description Qty 21 A09 6 1701 105 Release Valve 1 22 554 7 0062 007 Oil Seal 1 23 649 1 0050 019 Screw 1 24 653 1 0080 025 Screw 2 25 661 2 0080 023 Nut 2 26 324 4 1900 20...

Page 7: ...t Assy 1 15 A22 4 2040 107 Air Hose Assy 1 16 A27 3 2000 104 Air Motor Assy 1 17 649 1 0050 019 Hex Socket Bolt 1 18 A20 6 1707 108 Release Valve 1 19 A07 3 3300 307 Flexible Joint Assy 1 20 A22 6 322...

Page 8: ...20060 0007 Lift Control Valve 1 Replacement Parts for model 23301 Item Part No Description Qty 19 A20060 0016 Air Coupler Male 1 4 NPT 1 20 A07 3 3300 307 Release Valve Cable 1 21 A20 6 1701 108 Relea...

Page 9: ...7 A20060 0006 Air Hose 1 Replacement Parts for model 23501 Item Part No Description Qty 18 A20060 0007 Lift Control Valve 1 19 A20060 0016 Air Coupler Male 1 4 NPT 1 20 A07 3 3300 307 Release Valve Ca...

Page 10: ...Hose 1 18 A20060 0007 Lift Control Valve 1 Replacement Parts for model 23991 Item Part No Description Qty 19 A20060 0016 Air Coupler Male 1 4 NPT 1 20 A07 3 3300 307 Release Valve Cable 1 21 A20 6 17...

Page 11: ...LOSS WHATSOEVER 3 ANY IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO ONE YEAR OTHERWISE THE REPAIR...

Page 12: ...12 Contact SFA Companies 10939 N Pomona Ave Kansas City MO 64153 U S A Tel 888 332 6419 Fax 816 891 6599 E Mail sales omegalift com Omega Website http www omegalift com Note Page...

Reviews: