6-DIGIT 0.56" RED SUNLIGHT READABLE DISPLAY

z

4 SEPARATE DISPLAYS (Timer, Counter, Real-Time Clock, and Date)

z

CYCLE COUNTING CAPABILITY

z

PROGRAMMABLE FUNCTION KEYS/USER INPUTS

z

FOUR SETPOINT ALARM OUTPUTS (W/Plug-in card)

z

COMMUNICATIONS AND BUS CAPABILITIES (W/Plug-in card)

z

PC SOFTWARE AVAILABLE FOR METER CONFIGURATION

z

NEMA 4X/IP65 SEALED FRONT BEZEL

GENERAL DESCRIPTION

The PTC900 (Timer) and PTC901 (Clock/Timer) offer many features and

performance capabilities to suit a wide range of industrial applications. Both can
function as an Elapsed Timer or Preset Timer, while the PTC901 also offers
Real-Time Clock with Date capability. The Plug-in option cards allow the
opportunity to configure the meter for the present application, while providing
easy upgrades for future needs.

Both units can function as an Elapsed Time Indicator. By using two separate

signal inputs and 23 selectable timer ranges, the meters can be programmed to
meet most any timing application. With the addition of a Plug-in Setpoint card,
they can easily become a dual or quad output preset timer.

The PTC901 can also operate as a Real-Time Clock (RTC), with the Real-

Time Clock Card already installed. The meter is capable of displaying time in
12 or 24-hour time formats. The 12-hour format can be displayed in hours and
minutes, with or without an AM/PM indication or in hours, minutes, and
seconds. The 24-hour format can be displayed in hours and minutes or in hours,
minutes, and seconds. The PTC901 is also capable of a calendar display in
which the day, month and/or year can be displayed. The meter will recognize
leap years, and can automatically adjust for Daylight Savings Time. The Real-
Time Clock has the ability to externally synchronize with other PTC901 meters
to provide a uniform display network throughout the plant.

If the application calls for both a Preset Timer and a Real-Time Clock at the

same time, the PTC901 can handle this requirement as well. The meter provides
up to four different displays, accessed via front panel push buttons or external
inputs. The displays are Timer (TMR), which displays the current timer value;
Count (CNT), which displays the current cycle counter value; Date (DAT),
which displays the current programmed date; and Real-Time Clock, which
displays the current time. A battery-backed Real-Time Clock plug-in card is
provided with the PTC901. This card, which includes a lithium coin-cell battery,
will maintain the time and date when main power is removed.

The meters accept inputs from a variety of sources including switch contacts

and outputs from CMOS or TTL circuits. The input can be configured to trigger
on the edge or level of the incoming pulse. Internal jumpers are available to allow
the selection for sinking inputs (active low) or sourcing inputs (active high).

The front panel keys and three user inputs are programmable to perform

various meter functions. One of the functions includes exchanging parameter
lists, allowing for two separate listings of setpoint values, timer start/stop
values, counter start/stop values and RTC daily on and off values.

The meters can have up to four setpoint outputs, determined by the optional

plug-in cards. The setpoint plug-in cards provide dual FORM-C relays (5A),
quad FORM-A relays (3A) or either quad sinking or quad sourcing open
collector logic outputs. The outputs can be assigned to the timer, counter, RTC
date, and RTC time. The outputs can also be independently configured to suit a
variety of control and alarm requirements.

Plug-in cards can also provide serial communications. These include RS232,

RS485, and Modbus. Display values, setpoint alarm values and setpoint states
can be controlled through serial communications. With the RS232 or RS485
communication card installed, it is possible to configure the meter using a
Windows

®

based program. The meter configuration data can be saved to a file

for later recall.

Once the meters have been initially configured, the parameter list may be

locked out from further modification entirely, or the setpoint, timer start/stop
values, counter start/stop values, RTC time SET, and Display Intensity can be
made accessible. This lockout is possible through a security code or user input.

The meters have been specifically designed for harsh industrial environments.

With a NEMA 4X/IP65 sealed bezel and extensive testing to meet CE
requirements, the meter provides a tough yet reliable application solution.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in this

literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use this unit to directly command motors, valves, or other actuators

not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the unit.

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting

clip installation is 2.1" (53.4) H x 5" (127) W.

C

US LISTED

US LISTED

UL

R

IND. CONT. EQ.

51EB

Summary of Contents for PTC900

Page 1: ...TC C9 90 00 0 P PT TC C9 90 01 1 Panel M Mount P Programmable Timer a and R Real T Time C Clock omega com e mail info omega com For latest product manuals omegamanual info User sGuide Shop online at LP0678A ...

Page 2: ...omegashop cz Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 639 7678 e mail info omega de United Kingdom One Omega Drive River Bend Technology Centre ISO 9002 Certified Northbank Irlam Manchester M44 5BD United Kingdom TEL 44 0 161 777 6611 FAX 44 0 161 777 6622 Toll Free in United Kingdom 0800 488 488 e mail sale...

Page 3: ...ntacts and outputs from CMOS or TTL circuits The input can be configured to trigger on the edge or level of the incoming pulse Internal jumpers are available to allow the selection for sinking inputs active low or sourcing inputs active high The front panel keys and three user inputs are programmable to perform various meter functions One of the functions includes exchanging parameter lists allowi...

Page 4: ...d filter results in 50 msec start stop response time for successive pulses on the same input terminal 11 USER INPUTS Three programmable user inputs Logic inputs configurable as Current Sinking active low or Current Sourcing active high through a single plug jumper Current Sinking active low VIL 0 9 V max 22KΩ pull up to 12 VDC Current Sourcing active high VIH 3 6 V min 22KΩ pull down Max Continuou...

Page 5: ...f the outputs can be reversed in the programming These plug in cards include LDP6 CDS10 Dual Relay FORM C Normally open closed LDP6 CDS20 Quad Relay FORM A Normally open only LDP6 CDS30 Isolated quad sinking NPN open collector LDP6 CDS40 Isolated quad sourcing PNP open collector DUAL RELAY CARD Type Two FORM C relays Isolation To Timer User Input Commons 2300 Vrms for 1 min Working Voltage 240 Vrm...

Page 6: ... The bezel should only be cleaned with a soft cloth and neutral soap product Do NOT use solvents Continuous exposure to direct sunlight may accelerate the aging process of the bezel Do not use tools of any kind screwdrivers pens pencils etc to operate the keypad of the meter PANEL CUT OUT 1 0 INSTALLING THE METER 2 0 SETTING THE JUMPERS To access the jumpers remove the meter base from the meter ca...

Page 7: ... installation and wiring methods must be followed to ensure compatibility in each application The type of the electrical noise source or coupling method into the meter may be different for various installations The meter becomes more immune to EMI with fewer I O connections Cable length routing and shield termination are very important and can mean the difference between a successful or troublesom...

Page 8: ... Switch or Isolated Transistor Current Sink Switch or Isolated Transistor Current Source Emitter Follower Current Source 4 1 POWER WIRING AC Power Terminal 1 VAC Terminal 2 VAC DC Power Terminal 1 VDC Terminal 2 VDC 4 3 USER INPUT WIRING Before connecting the wires the Timer Input logic jumper should be verified for proper position When the user input is configured for cycle count in module 4 the ...

Page 9: ... device Some devices cannot accept more than two or three characters in succession without a pause in between In these cases the meter employs a busy function As the meter begins to transmit data the RXD line RS232 is monitored to determine if the receiving device is busy The receiving device asserts that it is busy by setting the RXD line to a space condition logic 0 The meter then suspends trans...

Page 10: ...the Host Real Time Clock Synchronization Figure 4 6 REAL TIME CLOCK WIRING PTC901 5 0 REVIEWING THE FRONT BUTTONS AND DISPLAY Cycle counter and Real Time Clock displays are locked out in Factory Settings Factory setting for the F1 and F2 keys is NO mode Factory setting for the RST key is Reset Display Selects digit location in parameter values Reset Function key RST Decrement selected parameter va...

Page 11: ... STEP PROGRAMMING INSTRUCTIONS OVERVIEW PROGRAMMING MENU DISPLAY MODE The meter normally operates in the Display Mode In this mode the meter displays can be viewed consecutively by pressing the DSP key The annunciators to the left of the display indicate which display is currently shown Timer TMR Cycle Counter CNT or Date DAT The Time Display for the Real Time Clock is shown with no annunciator An...

Page 12: ...Inhibit Level Active Time Start Time Stop Time Start Time Stop TIMER INPUT OPERATION 0 01 HR 0 001 HR 1 HR 0 1 HR 0 001 MIN HOURS 0 1 MIN 0 01 MIN MINUTES 1 MIN 0 01 SEC 0 001 SEC 1 SEC 0 1 SEC MAXIMUM DISPLAY DISPLAY RESOLUTION RANGE SELECTION SECONDS DAYS HOURS MINUTES 1 MIN 1 SEC 0 1 SEC 0 001 MIN HOURS MINUTES SECONDS 0 1 MIN 0 01 MIN HOURS MINUTES 1 MIN 0 01 SEC 0 001 SEC 1 SEC 0 1 SEC MAXIMU...

Page 13: ...n Keys Three rear terminal User Inputs are individually programmable to perform specific meter control functions While in the Display Mode the function is executed when the User Input transitions to the active state Refer to the User Input specifications for active state response times Certain User Input functions are disabled in Full Programming Mode User Inputs should be programmed while in the ...

Page 14: ...in the sublist The sublist appears when the PAR key is pressed This function does not apply to the RTC Time or Date displays NO Cycle Counter C dSP NO Timer t dSp FACTORY DESCRIPTION DISPLAY ª ª MOMENTARY RESET Edge Triggered When activated momentary action the meter resets the displays entered as in the sublist Function does not apply to RTC Time or Date displays ª ª DISPLAY HOLD Level Active Whe...

Page 15: ...RESET Edge Triggered NO Setpoint 4 SP 4 NO Setpoint 3 SP 3 NO Setpoint 2 SP 2 NO Setpoint 1 SP 1 FACTORY DESCRIPTION DISPLAY When activated momentary action the display intensity changes to the next intensity level of 4 The four levels correspond to Display Intensity Level settings of 0 3 8 15 The intensity level when changed via the User Input Function Key is not retained at power down unless Qui...

Page 16: ... after entering a matching security code or the universal unlock code of With this lock out a User Input would not have to be used for the Program Lock out function Note however the Security Code lock out is overridden when an User Input configured for Program Lock out is not active See Chart SECURITY CODE ª PROGRAMMING MODE ACCESS Throughout this bulletin Programming Mode without Quick in front a...

Page 17: ...ed CYCLE COUNTER STOP VALUE ª to CYCLE COUNTER RESET AT POWER UP The Cycle Counter can be programmed to Reset at each meter power up ª 6 5 MODULE 5 TIMER OPERATING MODES PARAMETER MENU This module can only be accessed if a Setpoint Card is installed Only the value parameters which apply to the selected mode will appear Interval Timing Edge Triggered INt E Interval Timing Level Triggered INt L On D...

Page 18: ...ULE 2 User Input Parameters MODULE 6 Setpoint Parameters P UP 1 Lit 1 OrSd 1 AUtO 1 tstP 1 tOUt 1 SPOf 1 OFf 1 SP 1 ON 1 OFF OFF OFF OFF OFF OFF Power up State NOr NOr NOr NOr NOr NOr Setpoint Annunciator NO NO NO NO NO NO Output Reset w display Reset NO NO NO 0 OFF NO NO Timer Counter Auto Reset 0 OFF 0 OFF 0 OFF NO 0 OFF NO Timer Stop T N A T2 N A N A N A Time out Value N A T N A T2 T N A Setpoi...

Page 19: ...value is entered in month day year format When assigned to the Real Time Clock Time Display the Setpoint value is always entered in format Hours Minutes with AM PM selection In Setpoint One shot mode See Daily On Occurrence the One shot Setpoint is enabled armed by scrolling the AM PM digit until the 2nd digit decimal point is lit SETPOINT OFF ª ª to Based on Setpoint Off Setting After Time Out Va...

Page 20: ...on This value is always entered in minutes seconds and hundredths of seconds format The maximum Time Out Value is 99 minutes 59 99 seconds ª TIMER COUNTER AUTO RESET When the Setpoint output activates or deactivates the meter automatically resets the Setpoint Assignment display Select if the Setpoint output should not cause the assigned display to reset Does not apply to manual activations or deac...

Page 21: ...needed and a value of zero can be used With multiple meters RS485 applications a unique 2 digit address number must be assigned to each meter Addresses 98 and 99 are reserved to configure a unit as a serial real time clock master See Serial Real time Clock Master Adressing to TST TSP CST CSP NO Timer Cnt Start Stop Values StrStp SO1 SO2 SO3 SO4 NO Setpoint Off Time Out Values SpNtOF SP1 SP2 SP3 SP...

Page 22: ...position is set for 0 0 and 25 is written to a register The value of the register is now 2 5 In this case write a value of 250 to equal 25 0 For RTC Time C and Date D Value Time 24 Hours Minutes Seconds HHMMSS Ex 083000 8 30 AM 144500 2 45 PM Date Month Day Year mmddyy Ex 123101 December 31 2001 Day 1 Sunday through 7 Saturday EX 3 Tuesday Notes 1 Since the meter does not issue a reply to value ch...

Page 23: ...eturn 14 LF Line feed 15 SP Space 16 CR Carriage return 17 LF Line feed 50 100 msec for 2 50 msec for Print P 50 100 msec for 2 50 msec for Transmit T 100 200 msec Write V 2 50 msec Reset R PROCESS TIME t2 COMMENT COMMAND COMMAND RESPONSE TIME The meter can only receive data or transmit data at any one time half duplex operation During RS232 transmissions the meter ignores commands while transmitt...

Page 24: ...cluding the parity bit is either even or odd This bit is used by the receiver to detect errors that may occur to an odd number of bits in the transmission However a single parity bit cannot detect errors that may occur to an even number of bits Given this limitation the parity bit is often ignored by the receiving device The meter ignores the parity bit of incoming data and sets the parity bit to ...

Page 25: ...ing network The time date or day will also be transmitted and updated in the Slaves when changed in the programming of the Serial RTC Master Only one meter should be configured as Master and that meter should also be configured as the Host ª CALIBRATE REAL TIME CLOCK The Real Time Clock circuit uses a crystal controlled oscillator for high accuracy timekeeping The oscillator is factory calibrated ...

Page 26: ...ions PROGRAMMING LOCKED OUT CHECK User input set for program lock out function is in Active state ENTER Security code requested TIMER NOT RUNNING CHECK Input wiring Timer plug jumper setting Timer input programming in Module 1 input signal level Timer Inhibited by Input B or a user input CERTAIN DISPLAYS ARE LOCKED OUT CHECK Display Lock out programming in Module 3 MODULES or PARAMETERS NOT ACCESS...

Page 27: ...C C Src NONE VALUE C dir CYCLE COUNTER STOP VALUE A 000000 UP C Strt CYCLE COUNTER STOP VALUE B CYCLE COUNTER START VALUE A OOOOOO 000000 C StOP C p UP CYCLE COUNTER STOP A B CYC CNTR RESET AT POWER UP CYCLE COUNTER START VALUE B NO NO 000000 DISPLAY PARAMETER USER SETTING FACTORY SETTING PARAMETER VALUE CHART Programmer ________________ Date ________ Clock Timer Meter _____________ Security Code ...

Page 28: ...INT OFF B TIME OUT VALUE B TIME OUT VALUE A 000100 SETPOINT OFF VALUE A VALUE SETPOINT OFF A LAtCH LAtCH LAtCH VALUE NO Mon Fri Mon Fri Mon Fri Mon Fri 000000 000000 VALUE VALUE NONE SP 4 USER SETTING NO Mon Fri Mon Fri Mon Fri Mon Fri 000000 000000 VALUE NONE SP 3 LAtCH FACTORY SETTING USER SETTING FACTORY SETTING VALUE NO Mon Fri Mon Fri Mon Fri Mon Fri 000000 000000 VALUE VALUE SETPOINT ON B NO...

Page 29: ... Value Setpoint 1 Time out Value Setpoint Select Setpoint Assignment Setpoint Action Output Logic Setpoint On Setpoint Off Time out Value Daily On Occurrence Daily Off Occurrence Timer Stop Timer Counter Auto Reset Output Reset w Display Reset Setpoint Annunciator Power up State Baud Rate Data Bit Parity Bit Meter Address Set Time Factory Service Code Setpoint number Set Date Set Day Time Display ...

Page 30: ...ut card with terminal block Communications Setpoint Alarms DP6 CDS40 Quad Setpoint sourcing open collector output Card DP6 CDS30 Quad Setpoint sinking open collector output Card DP6 CDS20 Quad Setpoint relay output Card DP6 CDS10 Dual Setpoint relay output Card PART NUMBERS DESCRIPTION DESCRIPTION PART NUMBERS Real Time Clock 85 250 VAC power Timer 85 250 VAC power PTC901 PTC900 Real Time Clock 11...

Page 31: ...otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans...

Page 32: ...ors Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conductivity Equipment DATA ACQUISITION Data Acquisition Engineering Software Communications Based Acquisition Systems Plug in Cards for Apple IBM Compatibles Datalogging Systems Recorders Printers Plotters ...

Reviews: