For Model with thermocouple socket 

The non-contact infrared thermometer is the ultimate tool for temperature measurements. It can measure from 100 to 1800

 o

C (212~3272

 o

F) in the 

distance of 75:1 DS (Distance to Spot) ratio. Furthermore, the memory mode can record and display the specific measurement with emissivity. There are 

many mathematical modes for the Infrared function.   

* Please remember to keep away from children and don’t use it for safety related applications. 

 

 

 

Simply  aim  the  thermometer  at  the  measure  target  with  Lens  (

11

)  and  press  Meas.  key  (

8

)  to  display  the  surface  temperature.  The 

Distance:Spot is 75:1. The two laser points are the reference for the target spot size. Please make sure the target area is within the field of view. 

 

FUNCTION   

Press Emissivity key (

3

) for setting the emissivity

 

 

Press Emissivity key (

3

), then press Up key (

4

) or Down key (

2

) to

 set the emissivity

, then press Mode key (

5

) to confirm it. The 

emissivity can be changed from 0.10 (10E) to 1 (100E). 

Press Mode key (

5

) for scrolling more display function as follows. 

 

Here will show the emissivity data. (The default emissivity is 0.95.) 

 

Press Mode key (

5

) for the

 Maximum (MAX), Minimum (MIN), Different between MAX and MIN (DIF) and Average (AVG) modes. 

During the measurement, the special modes reading will be displayed beside the mode icon.

 

 

 

 

 

Press Up key (

4

) or Down key (

2

) to change the

 High Alarm (HAL) 

or

 Lo Alarm (LAL)

, then press Meas. key (

8

) to confirm it. 

When the reading is outside the 

High Alarm (HAL)

 or 

Lo Alarm (LAL)

 limit. The High or Low icon will flash and you will hear a beep 

sound. 

 

 

Connect  the  thermocouple  with  Thermocouple  socket  (

7

)  and  put  the  probe  in/on  the  target,  the  thermometer  will  display  the 

temperature automatically without pressing any button. To see the minimum or maximum data during the probe measurement, please 

hold down the Up key (

4

) or Down key (

2

). 

  After measure high temp, the probe may remain HOT for a while. 

 

After taking the temperature, press Mode key (

5

) for the

 Memory (M00),

 then press Meas. key (

8

) to save the measurement. Under 

the

 Memory (M00) , 

press Up key (

4

) or Down key (

2

) key to display the record up to 24 sets. In “Memory” mode, press and hold the 

Up key (

4

), then press the Down key (

2

) for 2 seconds to clear the records. 

** The thermometer will automatically shut off if left idle for more than 60sec, unless in PRB mode. (In PRB mode, it will shut off if left idle for more than 12 

minutes.) 

ADD VALUE 

In MAX, MIN, DIF, AVG 

mode: 

Press  Up  key  (

4

)  for

  LOCK  mode

  ON/OFF.    The  lock  mode  is  particularly  useful  for  continuous  monitoring  of 

temperatures for up to 60 minutes. 
Press Down key (

2

) for

 

o

C

 or 

o

F transferred.

 

In all modes: First 

hold on the Meas. key 

(

8

and press Up key (

4

) for 

backlight function

 ON/OFF 

 

and press Down key (

2

) for

 laser function

 ON/OFF.   

(With flash light be turned on in the same time as laser ) 

 

Reviews: