background image

WARRANTY/DISCLAIMER

OMEGA  ENGINEERING,  INC.  warrants  this  unit  to  be  free  of  defects  in  materials  and

workmanship for a period of 

13 months

from date of purchase. OMEGA Warranty adds an additional

one (1) month grace period to the normal 

one (1) year product warranty

to cover handling and

shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. 
If  the  unit  should  malfunction,  it  must  be  returned  to  the  factory  for  evaluation.  OMEGA’s Customer
Service  Department  will  issue  an  Authorized  Return  (AR)  number  immediately  upon  phone  or  written
request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced
at  no  charge.  OMEGA’s WARRANTY  does  not  apply  to  defects  resulting  from  any  action  of  the
purchaser,  including  but  not  limited  to  mishandling,  improper  interfacing,  operation  outside  of  design
limits,  improper  repair,  or  unauthorized  modification.  This  WARRANTY  is  VOID  if  the  unit  shows
evidence of having been tampered with or shows evidence of being damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other
operating conditions outside of OMEGA’s control. Components which wear are not warranted, including
but not limited to contact points, fuses, and triacs.

OMEGA  is  pleased  to  offer  suggestions  on  the  use  of  its  various  products.  However,
OMEGA neither assumes responsibility for any omissions or errors nor assumes liability
for any damages that result from the use of its products in accordance with information
provided  by  OMEGA,  either  verbal  or  written.  OMEGA  warrants  only  that  the  parts
manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER
WARRANTIES  OR  REPRESENTATIONS  OF  ANY  KIND  WHATSOEVER,  EXPRESSED  OR
IMPLIED,  EXCEPT  THAT  OF  TITLE,  AND  ALL  IMPLIED  WARRANTIES  INCLUDING  ANY
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth
herein are exclusive and the total liability of OMEGA with respect to this order, whether
based  on  contract,  warranty,  negligence,  indemnification,  strict  liability  or  otherwise,
shall not exceed the purchase price of the component upon which liability is based. In
no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a
“Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in
medical  applications  or  used  on  humans.  Should  any  Product(s)  be  used  in  or  with  any  nuclear
installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes
no  responsibility  as  set  forth  in  our  basic  WARRANTY / DISCLAIMER  language,  and  additionally,
purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever
arising out of the use of the Product(s) in such a manner.

RETURN REQUESTS / INQUIRIES

Direct  all  warranty  and  repair  requests/inquiries  to  the  OMEGA  Customer  Service  Department.
BEFORE  RETURNING  ANY  PRODUCT(S)  TO  OMEGA,  PURCHASER  MUST  OBTAIN  AN
AUTHORIZED  RETURN  (AR)  NUMBER  FROM  OMEGA’S  CUSTOMER  SERVICE
DEPARTMENT  (IN  ORDER  TO  AVOID  PROCESSING  DELAYS).  The  assigned  AR  number
should then be marked on the outside of the return package and on any correspondence.
The  purchaser  is  responsible  for  shipping  charges,  freight,  insurance  and  proper  packaging  to
prevent breakage in transit.  
FOR 

WARRANTY

RETURNS, please have

the following information available BEFORE
contacting OMEGA:
1. P.O. number under which the product 

was PURCHASED,

2. Model and serial number of the product

under warranty, and

3. Repair instructions and/or specific 

problems relative to the product.

FOR 

NON-WARRANTY

REPAIRS, consult

OMEGA for current repair charges. Have the
following information available BEFORE
contacting OMEGA:
1.  P.O. number to cover the COST 

of the repair,

2. Model and serial number of product, and
3. Repair instructions and/or specific 

problems relative to the product.

OMEGA’s  policy  is  to  make  running  changes,  not  model  changes,  whenever  an  improvement  is  possible. 
This affords our customers the latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
©  Copyright  2002  OMEGA  ENGINEERING,  INC.  All  rights  reserved.  This  document  may  not  be  copied, 
photocopied,  reproduced,  translated,  or  reduced  to  any  electronic  medium  or  machine-readable  form,  in  whole  or  in  part,
without prior written consent of OMEGA ENGINEERING, INC.

USA

MADE

IN

PATENT NOTICE: This product is covered by one or more of the following patents: U.S. Pat. No. Des. 336,895;
5,274,577 / Canada 2052599; 2052600 / Italy 1249456; 1250938 / France Brevet No. 91 12756 / Spain 2039150;
2048066 / UK Patent No. GB2 249 837; GB2 248 954 / Germany DE 41 34398 C2
Used Under License. Other International Patents Pending.

Summary of Contents for iDRN-PS-1000

Page 1: ...L N USA MADE IN User sGuide www omega com e mail info omega com Shop on line at iDRN PS 1000 UNIVERSAL SWITCHING POWER SUPPLY Compact DIN Rail 24 Volt...

Page 2: ...6 D 75392 Deckenpfronn Germany TEL 49 0 7056 9398 0 FAX 49 0 7056 9398 29 Toll Free in Germany 0800 TC OMEGASM e mail germany omega com United Kingdom One Omega Drive ISO 9002 Certified River Bend Tec...

Page 3: ...5 3 2 Mounting on DIN Rail 6 3 3 Removal of Unit 7 4 Input and Output Connections 8 4 1 Block Diagram 8 4 2 Wiring for 115 Vac Single Phase 9 4 3 Wiring for 230 Vac Two Phase 10 5 Specifications 11 In...

Page 4: ...icant iDRN features include Tested isolation primary to output Recessed live parts and connector screws 35mm DIN rail mounting Wide input voltage tolerances Protective varistor input shunt Input AC sp...

Page 5: ...Furthermore to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment an overcurrent protection device shall be installed The Protective Con...

Page 6: ...packing of the power supply is recommended For units that must be shipped installed on the rail additional bracing to resist transportation shocks is recommended Do not attempt to install or connect t...

Page 7: ...be a minimum of 1 25mm spacing to allow sufficient air circulation for proper cooling Figure 3 1 Mounting INSTALLATION AND REMOVAL 3 5 DC POWER OUT AC POWER IN DC POWER IN SIGNAL INPUT DC POWER IN SI...

Page 8: ...N Rail To install unit onto DIN Rail 1 Tilt unit position mounting slot onto DIN Rail as shown 2 Push unit towards DIN Rail and it will snap into place Figure 3 2 Mounting on 35mm DIN Rail INSTALLATIO...

Page 9: ...3 7 3 3 Removal of Unit 1 Insert flat screw driver into tab and push downwards 2 Unit will detach from DIN Rail Figure 3 3 Removal of Unit INSTALLATION AND REMOVAL...

Page 10: ...ed all output connections Failure to do so may result in injury This device must only be installed electrically by a specially trained electrician with corresponding qualifications Warning To avoid po...

Page 11: ...c Single Phase L N Output Voltage for shielded wire connections if necessary Earth FUSE 1 LINE Switch NEUTRAL Earth Switch USE A SWITCH TO APPLY 24V POWER TO THE LOAD IF THE CAPACITANCE OF THE LOAD WI...

Page 12: ...CTIONS 4 10 L N Output Voltage for shielded wire connections if necessary Earth FUSE 1 L1 Switch L2 Earth FUSE 2 Switch USE A SWITCH TO APPLY 24V POWER TO THE LOAD IF THE CAPACITANCE OF THE LOAD WILL...

Page 13: ...age 24Vdc 2 850mA Resistive Load Output Wattage 20 Watts For higher output wattage greater than 20 watts follow the chart on section 7 Figure 6 2 Ripple less than 100 mVrms Operating Indicator Front P...

Page 14: ...ize Height 3 55 90mm Width 0 99 25mm Depth 4 38 111mm Weight 0 3 lbs 0 14 kg Equipment Type CLASS I Overvoltage CAT II Pollution Degree 2 Insulation input to ouput Dielectric strength to 2500V transie...

Page 15: ...DIMENSIONS 6 13...

Page 16: ...tage of 100V the maximum ambient temperature allowed is 40 C Figure 6 2 Temperature Derating Graph MAXIMUM POWER OUTPUT INPUT AC VOLTAGE AMBIENT TEMPERATURE C 120V 265V 115V 110V 105V 100V 25 C 5 C 30...

Page 17: ...NOTES 15...

Page 18: ...NOTES 16...

Page 19: ...special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2...

Page 20: ...locity Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industr...

Reviews: