background image

 

HH804W 

WIRELESS DUAL INPUT RTD 
DIGITAL THERMOMETER 

 
 
 
 
 
 
 
 

 
 
 
 

 

 

 

OMEGAnet

®

 On-Line Service 

omega.com

 

Internet e-mail 

[email protected]

 

Servicing North America: 

U.S.A:

 

One Omega Drive, Box 4047 

 Stamford, 

CT 

06907-0047 

ISO 9001

  Tel: (203) 359-1660 

FAX: (203) 359-7700

 

Certified

 e-mail: 

[email protected] 

Canada:

 976 

Bergar 

 

Laval (Quebec) H7L 5A1, Canada 

 

Tel: (514) 856-6928 

FAX: (514) 856-6886 

 e-mail: 

[email protected] 

 

For immediate technical or application assistance: 

U.S.A 

Sales Service: 1-800-826-6342/1-800-TC-OMEGA

® 

and 

Customer Service: 1-800-622-2378/1-800-622-BEST

® 

Canada: 

Engineering Service: 1-800-872-9436/1-800-USA-WHEN

®

 

 

TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA

 

Mexico:

 En 

Espan

ol: (001) 203-359-7803 

 e-mail: 

[email protected] 

 

FAX: (001) 203-359-7807  [email protected] 

 

Servicing Europe: 

Benelux: 

Postbus 8034, 1180 LA Amstelveen, The Netherlands 

 

Tel: +31 (0)20 3472121 

FAX: +31 (0)20 6434643 

 

Toll Free in Benelux: 0800 0993344 

 e-mail: 

[email protected]

 

Czech

 

Frystatska 184, 733 01 Karviná, Czech Republic 

Republic: 

Tel: +420 (0)59 6311899 

FAX: +420 (0)59 6311114 

 

Toll Free: 0800-1-66342 

e-mail: [email protected] 

France:

 

11, rue Jacques Cartier, 78280 Guyancourt, France 

 

Tel: +33 (0)1 61 37 2900  FAX: +33 (0)1 30 57 5427 

 

Toll Free in France: 0800 466 342 

 e-mail: 

[email protected] 

Germany/

  Daimlerstrasse 26, D-75392 Deckenpfronn, Germany 

Austria:

 

Tel: + 49 (0)7056 9398-0  FAX: +49 (0)7056 9398-29 

 

Toll Free in Germany: 0800 639 7678 

 e-mail: 

[email protected] 

United

 

One Omega Drive, River Bend Technology Centre 

Kingdom:

 Northbank, 

Irlam, 

Manchester 

ISO 9002

  M44 5BD United Kingdom 

Certified

  Tel: +44 (0)161 777 6611  FAX: +44 (0)161 777 6622 

 

Toll Free in United Kingdom: 0800-488-488 

 e-mail: 

[email protected] 

 
 
 
 

It is the policy of OMEGA Engineering, Inc. to comply with all 
worldwide safety and EMC/EMI regulations that apply. OMEGA 
is constantly pursuing certification of its products to the 
European New Approach Directives. OMEGA will add the CE 
mark to every appropriate device upon certification. 
The information contained in this document is believed to be 
correct, but OMEGA accepts no liability for any errors it 
contains, and reserves the right to alter specifications without 
notice. 

WARNING: 

These products are not designed for use in, and 

should not be used for, human applications.

INTRODUCTION

 

This instrument is a 4½ digit, compact-sized portable 

digital thermometer designed to use external 100

 Plati-

num RTD as temperature sensor. Temperature indication 
follows Reference Temperature/Resistance Tables (Pt385 
for European Curve, Alpha=.00385. Pt3926 for American 
Curve, Alpha=.003926. Pt3916 for Japan Curve, Al-
pha=.003916.) 
 

SAFETY INFORMATION 

It is recommended that you read the safety and opera-

tion instructions before using the thermometer. 

WARNING 

To avoid electrical shock, do not use this instrument 

when working voltages at the measurement surface 

over 24V AC or DC. 

 

WARNING 

To avoid damage or burns, do not make temperature 

measurement in microwave ovens. 

 

 

FEDERAL COMMUNICATIONS 

COMMISSION

 

This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following two condi-
tions:(1) this device may not cause harmful interfer-
ence, and (2) this device must accept any interference 
received, including interference that may cause unde-
sired operation. 
 

NOTE 

This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection. This equipment gener-
ates, uses and can radiated radio frequency energy and, 
if not installed and used in accordance with the in-
structions, may cause harmful interference to radio 
communications. However, there is no guarantee that 
interference will not occur in a particular installation If 
this equipment does cause harmful interference to ra-
dio or television reception, which can be determined 
by turning the equipment off and on, the user is en-
couraged to try to correct the interference by one or 
more of the following measures: 
 
- Reorient or relocate the receiving antenna. 
- Increase the separation between the equipment and 

receiver. 

- Connect the equipment into an outlet on a circuit dif-

ferent from that to which the receiver is connected. 

- Consult the dealer or an experienced radio/TV tech-

nician for help. 

 
Shielded interface cables must be used in order to 
comply with emission limits. 
Changes or modifications not expressly approved by 
the party responsible for compliance could void the 
user‘s authority to operate the equipment.

 

 

WIRELESS NOTE 

Wireless receiver must keep a distance at least 40cm 

from the meter and meter to meter distance 

must be at least 30cm.

 

 

M4552/0707

 