Omega Engineering FTB100 Series User Manual Download Page 2

Servicing North America:

U.S.A.:

Omega Engineering, Inc., One Omega Drive, P.O. Box 4047

ISO 9001 Certified

Stamford, CT 06907-0047
Toll-Free: 1-800-826-6342

Tel: (203) 359-1660

FAX: (203) 359-7700

e-mail: [email protected]

Canada:

976 Bergar
Laval (Quebec), H7L 5A1 Canada 
Toll-Free: 1-800-826-6342

TEL: (514) 856-6928

FAX: (514) 856-6886

e-mail: [email protected]

For immediate technical or application assistance:

U.S.A. and Canada:

Sales Service: 1-800-826-6342/1-800-TC-OMEGA

®

Customer Service: 1-800-622-2378/1-800-622-BEST

®

Engineering Service: 1-800-872-9436/1-800-USA-WHEN

®

Mexico

En Español: 001 (203) 359-7803

FAX: 001 (203) 359-7807

Latin America

[email protected]

e-mail: [email protected]

Servicing Europe:

Benelux:

Managed by the United Kingdom Office
Toll-Free: 0800 099 3344

TEL: +31 20 347 21 21

FAX: +31 20 643 46 43

e-mail: [email protected]

Czech Republic:

Frystatska 184
733 01 Karviná, Czech Republic
Toll-Free: 0800-1-66342

TEL: +420-59-6311899

FAX: +420-59-6311114

e-mail: [email protected]

France:

Managed by the United Kingdom Office
Toll-Free: 0800 466 342

TEL: +33 (0) 161 37 29 00

FAX: +33 (0) 130 57 54 27

e-mail: [email protected]

Germany/Austria:

Daimlerstrasse 26
D-75392 Deckenpfronn, Germany
Toll-Free: 0800 6397678

TEL: +49 (0) 7056 9398-0

FAX: +49 (0) 7056 9398-29

e-mail: [email protected]

United Kingdom:

OMEGA Engineering Ltd.

ISO 9001 Certified

One Omega Drive, River Bend Technology Centre, Northbank 
Irlam, Manchester M44 5BD United Kingdom
Toll-Free: 0800-488-488

TEL: +44 (0) 161 777-6611

FAX: +44 (0) 161 777-6622

e-mail: [email protected]

OMEGAnet

®

Online Service 

Internet e-mail

omega.com [email protected]

It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to the European New
Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.

The information contained in this document is believed to be correct, but OMEGA accepts no liability for any
errors it contains, and reserves the right to alter specifications without notice.

WARNING: 

These products are not designed for use in, and should not be used for, human applications.

Summary of Contents for FTB100 Series

Page 1: ...FTB100 and FTB200 Series Liquid Turbine Flowmeters...

Page 2: ...anaged by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free 08...

Page 3: ...s Liquid Turbine 3 3 Model Number 4 4 Principal of Operation 5 Material Selection and Construction 6 Flowmeter Calibrations 6 5 Installation 7 6 Maintenance and Troubleshooting 10 Pickup Coil Testing...

Page 4: ...2 1 Introduction The following information is provided for the proper installation and maintenance of your instrument...

Page 5: ...y 0 1 of reading over repeatable range Temperature Range 268 to 232 C 450 to 450 F End Fittings Standard NPT Optional MS flared and flanged styles Bearing Styles Self lubricating ceramic hybrid ballbe...

Page 6: ...4 3 Model Number...

Page 7: ...r dynamic positioning of the rotor between deflector cones The dynamic positioning of the low mass rotor provides wider rangeability and longer bearing life than that of conventional turbine flowmeter...

Page 8: ...ramic hybrid ball bearings and are made of 440C stainless steel Bearings are self lubricating type and do not require any external lubrication Flowmeter Calibrations The standard calibration provided...

Page 9: ...er calibration It is required to install meter with a minimum straight run of pipe approximately 10 pipe diameters ahead of the inlet and 5 pipe diameters following the outlet The meter housing is mar...

Page 10: ...purged prior to installing the meter To prevent possible damage to the meter install the meter ONLY in flow lines that are clean and free of debris Upon initial start up of the system a spool piece sh...

Page 11: ...pressure to prevent flashing cavitation in the metering run STRAINERS FILTERS Turbine flowmeters are designed for use in a clean fluid service However the service fluid may carry some particulate mat...

Page 12: ...0 10 PC13 74S 1850 15 PC24 45G 1350 10 PC24 45S 1850 15 PC28 13G 120 20 PC28 14G 180 20 If either resistance measurement fails replace the pickup coil When installing a coil make sure to firmly seat t...

Page 13: ...11 LockNut Hanger FlowStraightener Cone Shaft Bearing Rotor The shielded self lubricating 440c SS ball bearings may be changed in the field Figure 1 Exploded View Flowmeter Internals...

Page 14: ...the bearings and rotor onto the shaft making sure to reassemble with the IN side of rotor facing the IN side of the housing 10 Place the remaining cone on the shaft Gently rattle the flowmeter to sea...

Page 15: ...therwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold...

Page 16: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...

Reviews: