NOTES
Page 1: ...e 1 Hour 03 01 2008 09 42 10 32 9 0 Div 122 Input 1 32 122 Input 2 Input 2 Archives_Done F 03 02 2008 09 42 10 SP1_L below 044 5 F SP1_H above 090 0 F 67 8 77 7 9 0 Div User sGuide omega com e mail in...
Page 2: ...is document is believed to be correct but OMEGA Engineering Inc accepts no liability for any errors it contains and reserves the right to alter specifications without notice WARNING These products are...
Page 3: ...er the Network 18 4 3 Setup and Operation using the iSE Web Page 19 4 3 1 Read Sensor 20 4 3 1 1 Java Runtime Environment 1 4 Setup Instructions 20 4 3 1 2 Java Runtime Environment 1 5 5 0 Setup Instr...
Page 4: ...DOS Prompt 15 Figure 4 2 Assigning an IP Address using iConnect 16 Figure 4 3 Accessing the iSE s Home Page Menu 17 Figure 4 4 Access Control 18 Figure 4 5 iSE Home Page 19 Figure 4 6 LOGIN and ADMIN...
Page 5: ...risk of electrical shock CAUTION Risk of danger Tells you of circumstances or practices that can effect the instrument s functionality and must refer to accompanying documents TIP Provides you helpfu...
Page 6: ...wnload utility iFlash and Mail Notifier are available at the website listed on the cover page of this manual or on the CD ROM enclosed with your shipment 1 3 Description Web based Remote Surveillance...
Page 7: ...8 F The iSE can display and chart absolute measurements in two locations and a differential measurement between the two locations The iSE comes with a pair of type K thermocouples LINK TO WEB CAM OR I...
Page 8: ...cal and food processing and storage hospitals laboratories semiconductor fabs electronic assembly warehousing museums manufacturing greenhouses farm animal shelters and many more The following example...
Page 9: ...ng screw through the case and bracket Figure 2 1 Mounting 0 59 14 9 1 81 46 1 1 50 38 1 5 13 130 2 1 50 38 1 0 24 6 1 0 94 23 8 3 47 88 1 1 36 34 4 REAR WIRE ENTRY AREA ADDITIONAL MOUNTING OPTION TO R...
Page 10: ...es not matter if the iSE is powered ON or OFF just make sure that the DIP switch is set to OFF otherwise every time the unit is power cycled the factory settings will take over To enable the DHCP besi...
Page 11: ...es good network link DIAGNOSTICS LED Yellow Blinking Indicates transmitting data from iSE to flash memory card When DHCP enabled it remains solid until DHCP IP address is received LED Green Blinking I...
Page 12: ...In the absence of AC power and if S5 is installed the LCD Backlight and iSE board will be on and running on the battery power Refer to Section 2 7 Disconnect the power supply before proceeding Remove...
Page 13: ...and I O Contact Wiring Connections To access the Relay and I O Contact Connectors you must remove the cover refer to Section 2 4 Figure 2 8 Relay and I O Contact Connections 2 7 DC Power Input Wiring...
Page 14: ...e iSE board will be fully functional including Ethernet and the LCD backlight ON for approximately 1 hour You need to make sure that the LCD PWR field on the Configuration page of the iSE is set to UP...
Page 15: ...se the C F button 3 You will see the following message appear on the LCD WAIT FLASH 4 Wait for about 60 seconds and a new message should appear WAIT OKAY 5 Press the C F button once and this message w...
Page 16: ...your IP address to your computer s physical MAC address The MAC address can be found on a label attached to your device and contains 6 bytes 12 characters of hexadecimal numbers XX XX XX XX XX XX hex...
Page 17: ...character name stored as Host Name under the Access Control page in the iSE Home Page The default DNS name for an iSE is eis followed by the last four digits of the MAC address of that particular iSE...
Page 18: ...ough the TCP IP protocol There are three default TCP socket port numbers assigned to the iSE 1 Port socket number 1000 when using HTTPget program 2 Port socket number 2000 when trying to access the se...
Page 19: ...ith configuring the iSE you can always set your PC back to its original settings On your computer from the MS DOS Prompt window type ping 192 168 1 200 and press Enter If DHCP and DNS servers are used...
Page 20: ...T department for obtaining an IP address Figure 4 2 Assigning an IP Address using iConnect 1 Place the IP address in this box 2 Take the MAC address from the label attached to the bottom of the iSE an...
Page 21: ...e iSE for Configuration Click on the View Webpage button you will access the iSE s home page refer to Section 4 3 for details Figure 4 3 Accessing the iSE s Home Page Menu iSERVER HOME PAGE Read Senso...
Page 22: ...lt LOGIN password is 12345678 and the ADMINISTRATOR password is 00000000 then you should be on the Access Control page were you can simply type in the desired Static IP address and click Save Figure 4...
Page 23: ...gure 4 6 LOGIN and ADMINISTRATOR Passwords There are 2 different access levels 1 ADMINISTRATOR Password administrator allows certain groups and individual users to access and modify entire iSE paramet...
Page 24: ...a Runtime Environment you may download it from our website or contact the Customer Service Department nearest you Figure 4 7 Read Sensor 4 3 1 1 Java Runtime Environment 1 4 Setup instructions 1 Go to...
Page 25: ...Read Sensor web page there may be a problem with access through a winsock proxy server In such cases your network administrator will need to provide the winsock proxy server and port s If the administ...
Page 26: ...page it is strongly recommended to let the recording run for a minimum of 3 minutes if the time interval is 10 seconds from Configuration page and 15 minutes if the time interval is 1 minute Flash Arc...
Page 27: ...unications when downloading the stored data using the iFlash program it is strongly recommended to let the recording run for a minimum of 3 minutes if the time interval is 10 seconds from Configuratio...
Page 28: ...P address should be changed to fit user s networking environment Consult with your IT department for obtaining an IP address Gateway Address A gateway is a network point that acts as an entrance to an...
Page 29: ...click the Update button set the Activation to Status RTC Alarm and click the Update button one more time to review verify that the setup took place as it was intended 2 RTC is set and recording is in...
Page 30: ...ss Remote Port Remote Access Title Secured Applet TCP UDP Server Type Forward CR Number of Connections 5 Port 2000 Command TCP 2000 Disable 0 0 0 0 Click on Sensor No on left to modify Sensor Paramete...
Page 31: ...talled or a bad Flash Card 2 Megabytes 4 Megabytes 8 Megabytes available sizes of Flash Cards D Flash Card Message Describes RTC setup listed in the previous 4 scenarios Flash Card Module Malfunctiona...
Page 32: ...mA or 3 mA depending on OFF or ON selection respectively If recording is ON depending on the recording interval the LCD will be updated every 10 seconds or 1 minute Therefore when the LCD is set to O...
Page 33: ...the recording data However for large amounts of data 1 Month or 1 Year it may take 4 to 8 minutes to download the data In Archives_Enabled mode charting remains static while data download is taking p...
Page 34: ...ished if the Remote IP Address is set to the IP address of that specific node Server Type Continuous mode sends the temperature to the Ethernet every two seconds It is mainly used to send readings to...
Page 35: ...se Remote Access Remote Access can be enabled and disabled If enabled the iSE can send its data to a remote node on the same network the Remote IP address and Remote Port must be entered TCP UDP when...
Page 36: ...Parameters page for Input Contact 1 Figure 4 13 Sensor Parameters Input Contact SENSOR PARAMETERS No 4 Sensor Name Main Menu http 192 168 1 200 Sensor Parameters Update Reset Input Contact 1 Remote En...
Page 37: ...ture setting the remote site will show T75 7F This format setup was originally made for the iLD Display which has four or six LEDs For six LEDs T00 00F format and for four LEDs 00 0F format are approp...
Page 38: ...duct Generally HTTPget is used for simply programming an IP address to the iSE or for quickly obtaining a reading of from a device The iSE product must be configured from the configuration web page so...
Page 39: ...tically installed when you install the MailNotifier software available on our website and CD Notes on using HTTPget The HTTPget exe program is installed to the windows directory usually c winnt or c w...
Page 40: ...and battery status SRYRST Reset Power on iSE SR_XD1 Exclude alarm 1 disable alarm 1 function SR_XD2 Exclude alarm 2 disable alarm 2 function SR_XC1 Reset relay 1 latch condition SR_XC2 Reset relay 2 l...
Page 41: ...he following command to assign new IP to the device httpget r S 00000000 192 168 1 200 1 where 00000000 is admin password If the password is wrong the unit will ignore the new IP If the new IP is take...
Page 42: ...t static entry to the ARP cache arp d Use this command to manually delete a static entry Ping the destination computer using IP address first before using the arp a command The following window shows...
Page 43: ...Ethernet or the internet a Download the iLog software from the website listed in this manual b Install iLog software on a networked PC This software is compatible with Windows 95 98 NT 2000 and XP c F...
Page 44: ...ith existing email that supports the MAPI messaging interface If MS Outlook has been loaded the MAPI support should be available 4 8 1 Installation The Mail Notifier must be loaded on a computer runni...
Page 45: ...to 2005 The Mail Notifier will attempt to automatically identify whether the Outlook is a newer version A red bar appears under the Mail Notifier splash window to confirm that the detection of the 200...
Page 46: ...ibe the alarm condition Email Interval the time interval in which the email is sent Monitor Interval the interval or time resolution in which readings will be obtained from the device Alarm Hold Time...
Page 47: ...F 256 to 2502 F 1 8 F 0 7 F 270 to 190 C 190 to 400 C 1 0 C 0 4 C Copper Constantan 454 to 310 F 310 to 752 F 1 8 F 0 7 F 270 to 220 C 220 to 1000 C 1 0 C 0 4 C CHROMEGA Constantan 454 to 364 F 364 to...
Page 48: ...2 Contact Inputs 1 Open Collector Output 150mA 30 Vdc Management Device configuration and monitoring through embedded WEB server Embedded WEB Server Serves WEB pages containing real time data and live...
Page 49: ...sk 255 255 255 0 Device Host Name eis and the last 4 digits from the MAC address Login Password 12345678 Admin Password 00000000 DHCP Disabled Terminal Server Server Type Command Number of Connections...
Page 50: ...adaptor must have Safety Qualified Agency Approvals for CE with Double Insulation rating The ac dc power adaptor is 9Vdc The minimum output current rating is 500mA EMC EN61000 6 1 2001 Immunity and E...
Page 51: ...32 bit pattern of bits used to determine which part of the IP address is the network portion and which part is the host portion MAC Media Access Control Address is your computer s unique hardware numb...
Page 52: ...pport approximately 216 65 536 computers per network The IP addresses range in binary from 10000000 00000000 xxxxxxxx xxxxxxxx to 10111111 11111111 xxxxxxxx xxxxxxxx The IP addresses range in decimal...
Page 53: ...Mask Dotted Notation Mask Binary Mask Bits Class A 255 0 0 0 Default 0 255 192 0 0 2 255 224 0 0 3 255 240 0 0 4 255 248 0 0 5 255 252 0 0 6 255 254 0 0 7 255 255 0 0 8 255 255 128 0 9 255 255 192 0...
Page 54: ...01010010 DC3 19 13 00010011 S 83 53 01010011 DC4 20 14 00010100 T 84 54 01010100 NAK 21 15 00010101 U 85 55 01010101 SYN 22 16 00010110 V 86 56 01010110 ETB 23 17 00010111 W 87 57 01010111 CAN 24 18...
Page 55: ...11 Crtl Q Data Control 1 XON SOH 01 01 Crtl A Start of DC2 18 12 Crtl R Data Control 2 Header STX 02 02 Crtl B Start of Text DC3 19 13 Crtl S Data Control 3 XOFF ETX 03 03 Crtl C End of Text DC4 20 1...
Page 56: ...7 Windows socket error Wrong IP or wrong Port number was used 10008 The iSE failed to respond to a request Wrong IP or wrong Port number was used 10011 Response came empty No data was sent 10012 Devic...
Page 57: ...NOTES...
Page 58: ...NOTES...
Page 59: ...ONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications...
Page 60: ...city Indicators Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industria...