OMEGA AIR WOSm Series Installation And Operating Manual Download Page 4

WOSm - Installation and operating manual 

 4 

Safety instructions 

 

The relevant safety at work and accident prevention regulations, plus operating instructions, 
shall apply for operating the separator. The separator has been constructed in accordance 
with the generally recognized rules of engineering. 

Ensure that installation complies with local laws and directives. 

Operator/user of the separator should make himself familiar with the function, installation 
and start-up of the unit. All the safety information is always intended to ensure your 
personal safety. 

 

Do not apply pressure to the separator. 

 

The permissible working temperatures and pressures for ad-on parts and separator 
elements are given under “Technical data sheet” and “Installation and operating 
manual” for those ad-ons. Maximum temperature and pressure for assembled 
system is the lowest of any individual part. 

 

The medium used may not have any corrosive components that could attack the 
materials of the separator in a way that is not permitted. Do not use the separator in 
hazardous areas with potentially explosive atmospheres. 

 

All installation and maintenance work on the separator may only be carried out by 
trained and experienced specialists. 

 

It is forbidden to carry out any kind of work on the separator and piping, including 
welding and constructional changes, etc. 

 

Depressurize the system before carrying out the installation work. 

 

Use original spare parts only. 

 

Use the device for appropriate purpose only. 

 

There shouldn’t be any tension between separator and installation. Separator 
shouldn’t be subject to any stress, vibration or other influence that could cause 
damage to the unit. 

 

 

Summary of Contents for WOSm Series

Page 1: ...g manual WOSm water oil separator Please read the following instructions carefully before installing separator housing unit into service Trouble free and safe operating of the unit can only be guaranteed if recommendations and conditions stated in this manual are respected ...

Page 2: ...WOSm Installation and operating manual 2 Components Part 1 Filter head 2 Inlet connection 3 Outlet connection 4 Wall mounting bracket 5 Filter cap 6 O rings 7 Filter element 1 2 3 4 5 6 7 ...

Page 3: ...ssive not suitable for emulsion Nr of inlet connections 1 1 Nr of outlet connection 1 1 Connection type Push in fitting for hose diameter 8mm Residual oil content 20ppm Service interval When first of the following parameters appears 4000 operating hours of compressor 2 12 months regardless compressor operating hours All white polypropylene filling becomes yellow adsorbed oil DIMENSIONS A mm 475 81...

Page 4: ...and Installation and operating manual for those ad ons Maximum temperature and pressure for assembled system is the lowest of any individual part The medium used may not have any corrosive components that could attack the materials of the separator in a way that is not permitted Do not use the separator in hazardous areas with potentially explosive atmospheres All installation and maintenance work...

Page 5: ... or unreasonable use Use genuine spare parts only Any damage or malfunction caused by the use of ungenuine parts is not covered by Warranty or Product Liability Advanced dimensioning For advanced dimensioning please use following equations Oil carry over c can be determined by measuring oil volume at two sequential compressor services In order to determine oil carry over compare initial volume of ...

Page 6: ...and tighten cartridge to the cyclonic chamber make sure that o rings are in appropriate position Connect device to the system At least 10 outlet pipe hose slope recommended Trapped air prevents condensate to flow into or out of the WOSm separator During installation ensure that no water pockets are formed in the inlet outlet pipe hose Outlet must be connected to the sewage system Warning It is str...

Page 7: ...aper For test set please contact us or your local distributor To replace filter element follow this steps Remove plastic cap from NEW filter element fill the cartridge with clean water and close it back with plastic cap Please pay attention to warning specified in INSTALLATION chapter The housing O ring should also be changed at the same time the filter is changed Close condensate inlet or make su...

Page 8: ...s operated when it was clearly defective Non original spare parts or replacement parts were used The unit was not operated within the permissible technical parameters Unauthorised constructional changes were made to the unit or if parts of the unit that may not be opened were dismantled OMEGA AIR d o o Ljubljana Cesta Dolomitskega odreda 10 SI 1000 Ljubljana Slovenia Tel 386 0 1 200 68 00 Fax 386 ...

Reviews: