AFs - Installation and operating manual
6
•
Lubricate the O-ring and the sealing surfaces of the filter head and cartridge, use
multipurpose grease (SILICONE FREE).
•
Fit the filter cartridge on the filter head simply by pressing, tightness is ensured by
one o-ring.
•
Fit the filter bowl and tight it accurately.
•
Filters must always be installed in a vertical position with sufficient space around. The
minimum distance (D in the technical data table) has to be assured under the filter
bowl, which is necessary for filter cartridge changing.
•
Stick the adhesive label showing the month and year for the next filtering element
change (max. one year) on the filter bowl.
•
Slowly pressurize the installation and check it for air leakage.
Models AFs 0946 to AFs 2406
The filter assembly and installation procedures are as follows:
•
If provided, install the pressure drop indicator or the Differential Pressure Gauge
(optional) on the filter head.
•
Connect the filter head to the compressed air piping and check that the airflow
corresponds to the direction of the arrow positioned on the filter head cap.
•
Clean accurately the piping and the filter head outlets, remove any shaving, slaver or
scrap from tooling.
•
Lubricate the O-ring and the sealing surfaces of the filter head and cartridge. Use
multi-purpose grease (SILICONE FREE).
•
Fit the filter cartridge on the filter head centering the filter bottom hole with the
screwed rod. Tight the hexagonal nut and fix the element.
•
Fit the filter bowl and tight it accurately.
•
Filters must always be installed in a vertical position with sufficient space around. The
minimum distance (D in the technical data table) has to be assured under the filter
bowl, which is necessary for filter cartridge changing.
•
Stick the adhesive label showing the month and year for the next filtering element
change (max. one year) on the filter bowl.
•
Slowly pressurize the installation and check for air leakage.