Technical Specifications
Model
VP-CN-0749
VP-CN-1066
Power
0.5 HP / 0.37 kW
1.2 HP / 0.9 kW
Seal bar
10.2” x 0.3” / 259 x 8mm
15.4” x 0.3” / 391 x 8mm
Cycle Time
30 seconds
23-25 seconds
Pump Power
10 m³/h
20 m³/h
Chamber Size
15.25” x 11” x 3.25”
387 x 279 x 83mm
19.75” x 16.25” x 4.5”
502 x 413 x 114mm
Electrical
110V / 60Hz / 1Ph
Net Weight
79.2 lbs. / 35.9 kgs.
96.8 lbs. / 43.9 kgs.
Gross Weight
96.8 lbs. / 43.9 kgs.
132 lbs. / 59.8 kgs.
Dimensions (DWH)
18.75” x 13” x 15.25”
476 x 330 x 387mm
24” x 18.25” x 20”
610 x 464 x 508mm
Item Number
19481
19482
Omcan carries all size of vacuum packaging bags for the above models.
Installation
PREPARATION BEFORE USE
1. Before operation, please read through the user guide about each operation rule and safety precaution.
2. You must fill the vacuum pump with pump oil before use (when the machine is placed at a horizontal
position, the oil should be kept at 1/3-1/2 in the oil window). When running, the oil level should not be lower
than 1/3 in the oil window. Do not fill with too much oil to avoid overflow.
3. The machine should be placed horizontally in a well ventilated and lit space, free from corrosive gas and
heavy dust.
4. Make sure that the machine is properly grounded before use.
5. Always ensure top cover is open before turning the power on. Start the machine by closing the top cover
and the process will start automatically.
6. Preheat of vacuum pump must be done in low temperature working area. Turn off the heater selection
switch at the control panel to off position. This is to prevent heating process and cut down wear and tear on
the unit.
Tip: In order to quickly process a small item or product using a bigger chamber is to place a solid
block into the chamber in order to occupy the chamber space so as to allow less vacuum time needed.
Note: Do not block the air hole in the chamber.
SETTING
Please set every parameter first before starting the machine.
1. Turn on the power supply, check through the setting shows on the panel and make sure “----” must be