background image

7

Operation

Maintenance

DIGITAL TEMPERATURE CONTROLLER

Small, integrated digital controller, which is applicable to the compressor of 1 Hp.

Main functions are: Temperature Display/Temperature Control/Manual-Automatic /Light Control/Value Storing/

Self-Testing/Parameter Locking.

FRONT PANEL OPERATION

1.  Set temperature: Press     button; set temperature will be displayed. Press     or     button to modify and 

store the displayed value. Press     button to exit the adjustment and display the cold-room temperature.

2.  If no button is pressed within 10 seconds, the cold-room temperature will be displayed.

3.  Lighting: Press     button to activate light in refrigerator; press again to turn off. Manual start/stop defrost: 

Press     button and hold for 6 seconds to either defrost or to stop defrost.

4.  Refrigeration LED: During refrigeration, the LED is on. When the cold room temperature is constant, the 

LED is off. During delay start, the LED flashes.

5.  Defrost LED: During defrosting, the LED is on. When it stops defrosting, the LED is off. During the delay of 

defrost, the LED flashed.

1.  Cabinet Cleaning: 

a. The product should be maintained and cleaned periodically with power supply disconnected. when 

cleaning, use mild-rinsing water or non-corrosive products. Do not wash directly with water faucet. 

b. Clean outside of unit using a soft cloth with neutral detergent, and dry with a separate soft cloth. 

c. Clean inside racks by removing them from the unit and clean with water.

2.  When shutting down unit for a long period of time, take out all food and unplug wall socket. Clean inside 

and outside thoroughly, and keep door open to sufficiently dry.

3.  As glass breaks easily, keep far away from children.

4.  Replacement of Lamp in Light Box: If the LED lamp is damaged, it must be replaced by Omcan or its 

service agent.

5. 

Frequently observe the operation of the product. In case of any abnormal noise or smell, cut off the power 

supply immediately and call professionals. Do not restart the product before source of trouble is found.

6. 

We will not be responsible for any accidents acquired through failure to follow previous notices

CAUTIONS

•  Minimizing time the time and frequency that the door is open will maintain temperature.

Summary of Contents for RS-CN-0118-E

Page 1: ...Revised 11 18 2019 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Countertop Refrigerated Display Model RS CN 0118 E Item 43074 Instruction Manual...

Page 2: ...10 11 12 14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Re...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...lquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recepcion de un envio...

Page 5: ...le should never share the power outlet with any other appliance as cable will overheat and may result in a fire Protect cables Extra caution should be used when handling cables as broken or damaged ca...

Page 6: ...Plug refrigerator into the 110V exclusive socket After the refrigerator is running confirm that air suction filtration is in order and that it is sufficiently cold After checking to make sure the ref...

Page 7: ...LED is off During the delay of defrost the LED flashed 1 Cabinet Cleaning a The product should be maintained and cleaned periodically with power supply disconnected when cleaning use mild rinsing wat...

Page 8: ...e supervised to ensure that they do not play with the appliance WARNING Keep ventilation openings clear of obstructions WARNING Do not use mechanical devices of other means to accelerate the defrostin...

Page 9: ...ver for RTW118L 16 77913 Upper Cover for Condenser for RTW118L 26 77888 Pillar for Glass for RTW118L 4 77901 Left Plate for Glass Cover for RTW118L 17 77914 Cover for Condenser for RTW118L 27 77889 Up...

Page 10: ...10 Parts Breakdown Model RS CN 0118 E 43074...

Page 11: ...11 Electrical Schematics Model RS CN 0118 E 43074...

Page 12: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 13: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 14: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 15: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 16: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: