12
Operation
INSTRUCTION OF CONTROL PANEL
1. LED Display:
• Self-check: Display “ini” code.
• Preparing: Counting seconds positively.
• Ice making: Counting seconds positively as the water temperature decreases to 0ºC. Counting seconds
down to 0 s after.
• Ice Harvest: Counting seconds positively.
• Clean: Display “CLE” during cleaning and descaling; Display “STL” during sterilizing; Display “rin” during
rinsing.
2. LED Lamps: Lights on during the related process.
3. Ice cube thickness adjustment: During the ice making process, if you are not satisfied with the ice
thickness, press the Ice cube “–” button for 3 seconds, then click the button “+” or “-” on the panel to adjust
the thickness of ice cube.
Note: By clicking the “+” or “-“ button one time, the ice making time is extended or shortened by
1.5 minutes.
4. Cleaning: During the normal operation, hold the cleaning button for 3 seconds to enter the cleaning
process. During the entire cleaning process, cleaning agents and disinfectants need to be put into the
water trough. When the clean process is finished, the ice maker will go to ice making process.
5. Switch: When the device is powered, click the “Switch” button to switch OFF/ON the device.
6. Voice function (only for machines with voice function): The machine with voice announcement prompts will
provide voice prompts for related operations.
7. Please open and close the ice bin door gently. Do not slam the door. After taken the ice cubes, please
close the door.
8. If the ice maker is not in use for a long time, it should be energized and run for 2 to 4 hours every 2 months.
OTHER SPECIAL PROTECTION - SHUTDOWN
• If the ice machine has not detected ice cube falling off in three cycles, it will shut down for safety protection.
The ice maker needs to be checked.