13
Controller Instructions
Table of Functions activated by the buttons - Models S, X, Y, C (Table 2)
Button
Normal Operation
Start Up
Pressing the Button Alone Pressed Together
Up
ON/OFF
More than 3 sec: toggle ON/
OFF
Start/Stop
continuous cycle
-
Down
Defrost
More than 3 sec: start/stop
defrost
Pressed
together
Start parameter
reset procedure
For 1 sec.
display
firmware
vers. code
Set Mute - 1 sec.: display/set the set
point.
- more than 3 secs.: access
parameter setting menu
(enter password )
- mute audible alarm
(buzzer)
-
For 1 sec.
RESET cur-
rent EZY set
Setting the set point (desired temperature)
• press
SET
for 1 sec, the set value will start flashing after a few moments;
• increase or decrease the value using
UP
or
DOWN
;
• press
SET
to confirm the new value.
Switching the device ON/OFF
Press
UP
for more than 3 sec. The control and defrost algorithms are now disabled and the Instrument
displays the message “OFF” alternating with the temperature read by the set probe
Manual defrost
Press for
DOWN
more than 3 sec (the defrost starts only the temperature conditions are valid).
Continuous cycle
Press
UP
and
DOWN
together for more than 3 sec
Access and setting type F (frequent) and type C (configuration) parameters
1. press
SET
for 3 sec (the display will show “PS”);
2. • to access the type F and C parameter menu, enter the password “22” using
UP/DOWN
, press
SET
to
confirm;
• to access the F parameter menu only, press
SET
(without entering the password);
3. scroll inside the parameter menu using
UP/DOWN
;
Summary of Contents for FR-CN-0686-HC
Page 18: ...18 Parts Breakdown Model RE CN 0006 HC 50054 ...
Page 20: ...20 Parts Breakdown Model RE CN 0011 HC 50056 ...
Page 22: ...22 Parts Breakdown Model FR CN 0686 HC 50053 ...
Page 24: ...24 Parts Breakdown Model FR CN 1219 HC 50055 ...
Page 26: ...26 Model RE CN 0006 HC 50054 Model RE CN 0011 HC 50056 Electrical Schematics ...
Page 27: ...27 Electrical Schematics Model FR CN 0686 HC 50053 Model FR CN 1219 HC 50055 ...