Troubleshooting
Maintenance
Symptom
Cause
Solution
The indicator is not on or the
compressor does not start.
The plug isn’t connected to the
socket.
Re-connect it.
No power.
Connect to a socket with power.
The indicator is on, but the
compressor doesn’t work and
buzzes only.
The power voltage is <110V.
Attach a power-regulator with more
than 1000W power.
The compressor stops a minute
after start, and restart after a few
minutes, and so repeatedly.
The power voltage is >110V.
•
The freezer should be cleaned regularly. When cleaning, turn off the power, take out the foods in the
cabinet, clean the inside using water or a little neutral detergent.
•
Do not use boiling water, acid, chemical diluters, petrol and oil, or dirt-removing powder.
•
Dry it after cleaning.
•
Use light soap water when cleaning the door seal, apply a little of talcum powder on it after natural drying to
extend its service life.
•
Use soft cloth with water or a little detergent to clean the out surface.
Note, keeping the power supply and lower part of connect wires away from water to avoid
electricity leakage.
•
Except common breakdowns, those who are not service technician should not take apart and repair the
freezer on their own so as to avoid worsening the trouble. Unauthorized repair of electrical part such as
compressor, temperature controller is forbidden.
DEFROSTING
• Defrost for better freezing efficiency when the frost film in the cabinet is 4-5mm thick.
•
When defrosting, turn off the power, take out the frozen foods, open the door for warming and melting. Use
soft cloth to absorb water and clean it up.
• Do not use sharp metal tools such as steel brush to clean the frost film when defrosting so as to avoid
evaporator damage.