background image

19

Warranty Registration

Gracias por comprar un producto Omcan usted. Para registrar su garantía para este producto, complete la información a continuación, 

cortar la tarjeta en la perforación y luego enviarlo a la dirección indicada a continuación. También puede registrarse en línea en:

Merci d’avoir acheté un produit Omcan. Pour enregistrer votre garantie pour ce produit, complétez les informations ci-dessous, détachez la 

carte au niveau de la perforation, puis l’envoyer à l’adresse spécifié ci-dessous. Vous pouvez également vous inscrire en ligne en visitant:

Thank you for purchasing an Omcan product. To register your warranty for this product, complete the information below, tear off the card at 

the perforation and then send to the address specified below. You can also register online by visiting:

OMCAN

PRODUCT WARRANTY REGISTRATION

3115 Pepper Mill Court,

Mississauga, Ontario

Canada, L5L 4X5

https://omcan.com/warranty-registration/

or email to: [email protected]

Purchaser’s Information
Name:

Company Name:

Address:

Telephone:

City:

Province or State:

Postal or Zip:

Email Address:

Country:

Type of Company:
     Restaurant

     Bakery

     Deli

Dealer from which Purchased:

     Butcher

     Supermarket

     Caterer

Dealer City:

Dealer Province or State:

     Institution 

(specify)

:

Invoice:

     Other 

(specify)

:

Model Name:

Model Number:

Serial Number:

Machine Description:

Date of Purchase (MM/DD/YYYY):

Date of Installation (MM/DD/YYYY):

Would you like to extend the warranty?      Yes      No

Por correo en Canadá

Pour postale au Canada

For mailing in Canada

Por correo en los EE.UU.

Pour diffusion aux États-Unis

For mailing in the US

OMCAN

PRODUCT WARRANTY REGISTRATION

4450 Witmer Industrial Estates, Unit 4,

Niagara Falls, New York

USA, 14305

Thank you for choosing Omcan | Merci d’avoir choisi Omcan | Gracias por elegir Omcan

Summary of Contents for CE-CN-HP12-M

Page 1: ...022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Gas Hot Plates Models CE CN HP12 M HP24 M HP36 M HP12 S HP24 S HP36 S Items 47379 47380 47381 47382 47383 47384 Inst...

Page 2: ...General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Registration Model CE CN HP12 M Model CE CN HP24 M Mo...

Page 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 4: ...o en el correcto funcionamiento de esta m quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mie...

Page 5: ...te every circumstance or environment in which its equipment will be operated It is the responsibility of the owner and the operator to remain alert to any hazards posed by the function of this equipme...

Page 6: ...this product Never bypass alter modify or attach any unauthorized parts to this equipment Doing so may create hazards and will void warranty Vender takes every care to ensure that all products are saf...

Page 7: ...305 x 701 x 330mm 24 x 27 6 x 13 610 x 701 x 330mm 36 x 27 6 x 13 914 x 701 x 330mm Packaging Dimensions 15 8 x 33 5 x 17 3 400 x 850 x 440mm 27 6 x 33 5 x 17 3 700 x 850 x 440mm 39 4 x 33 5 x 17 3 1...

Page 8: ...to be supplied by user must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa Technical Specifications STEP UP H...

Page 9: ...installation of equipment Therefore installation should comply with all local codes 4 This appliance is equipped for natural gas for conversion to LP gas please see another conversion kits instruction...

Page 10: ...ERSION Instructions are for conversion from Natural Gas to Propane L P on all models The conversion should be done before connecting the unit to the gas supply Units are shipped from the factory equip...

Page 11: ...to put the unit in service IGNITING THE BURNER To ignite the burner turn knob to the ON position Then back off to the desired flame level The range of adjustment is virtually infinite between ON and...

Page 12: ...y Body Use a clean cloth and a non abrasive cleaner to clean the stainless steel body of the hot plate Wipe the polished areas with a soft cloth Daily Controls Unit should be turned off when not in us...

Page 13: ...ain gas line leak Turn off main gas valve DO NOT LIGHT FLAME ignite anything or turn switch on anything electrical Call fire department if needed and call for service Cooking surface is heating up slo...

Page 14: ...14 Parts Breakdown Model CE CN HP12 M 47379 Model CE CN HP24 M 47380 Model CE CN HP36 M 47381...

Page 15: ...for 47380 13 AI807 Drop Pan for 24 Charbroiler Hot Plate for 47380 31 AI750 Regulator 4 10 for 47380 4 AI797 Rear Burner for Hotplate for 47380 14 AI808 Front Panel 4 Burner Hotplate for 47380 35 AI7...

Page 16: ...16 Parts Breakdown Model CE CN HP12 S 47382 Model CE CN HP24 S 47383 Model CE CN HP36 S 47384...

Page 17: ...plate for 47383 3 AI752 4 Adjustable Leg for 47383 10 AI800 Orifice Hotplate LP Gas for 47383 23 AI750 Regulator 4 10 for 47383 4 AI796 Front Burner for Hotplate for 47383 13 AI819 Drop Pan for 24 Cha...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: