10
Maintenance
8. Reinstall the previously removed master links as stated in step 2 & 3. Unhook the last link of the conveyor,
farthest away from you, and re-thread through the other end, and reconnect back onto itself.
9.
Examine the oven to assure proper installation, once satisfied, install crumb trays if you have not done so.
DO NOT OPERATE UNIT WITHOUT CRUMB TRAYS INSTALLED.
10. Reconnect oven to power supply and check for proper operation.
LUBRICATE THE CHAIN & SPROCKETS EVERY MONTH
1. DISCONNECT POWER SOURCE.
2. Remove the panel which exposes chain drive.
3. Using an extreme pressure, synthetic chain lubricant with a temperature range up to 400°F. Apply liberally
onto chain and sprockets.
4. Replace panel, reconnect power source and test unit.