Troubleshooting
Pilot repeatedly goes out.
Clogged pilot orifice.
Use a small wire to clear
obstruction from pilot orifice.
Pilot flame blowing away from
pilot generator (excessive draft in
kitchen).
Eliminate draft in kitchen.
Pilot generator not inserted fully
into pilot burner.
Reinsert pilot generator into pilot
burner until flame surrounds tip.
Corroded connection where pilot
generator connects to gas valve.
Clean pilot generator connection at
gas valve.
If all of the above causes have
been ruled out. The probable
causes are low pilot flame. Pilot
generator low millivolt output. High
resistance in hi-limit thermostat
contacts, or a defective pilot
magnet in the gas valve.
Call service.