Installation

to avoid problems of this nature.

8.  Air vent on door must be provided for built-in cabinet when a wood door installed.

In hot climate zone, an air vent or grid, with a minimum ventilation size of 200mm x 40mm MUST be cut out 

at the rear top of the back partitioning or at the top of either side of the partitioning, allowing cool fresh air full 

access to flow into the 30mm gap located at the rear of the cabinet. 

This air vent or grid must not be opened on the same side as other appliances such as ovens or an area that 

is sealed and without access to fresh cool air. Failing to comply with the above specifications could result in 

WARRANTY void.

REVERSING OF THE DOOR

1.  Depending on the model and the type of handle of the cabinet, you may need to rotate the door 180 

degrees or symmetrically change the direction of the door (according to the product’s own configuration).

2.  The door may be irreversible depending on the type of handles of the cabinet, or the door may need to be 

opened and replaced when ordering.

Warning: To avoid accidents during 

the process of changing the door, we 

recommend that you get assistance. The 

glass door is heavy and may cause injury 

if dropped.

1.  To put the cabinet on open operation 

place, the door opened to the maximum 

angle.

2. 

Use small knife (2) to take off the 

decorative nail (1) on opposite side 

(Drawing 1).

3. 

Use the inner six angle screwdriver (Tool 

5) to disassemble the screws (4) of drop-

proof device (3), then remove the drop-

proof device (Drawing 1).

4. 

Hold the door, use six angle screwdriver 

(Tool 5) to screw out the door shaft core 

(6) from the two ends of the top of the 

door. Take out the door and set aside 

(Drawing 2).

5.  Discharge the upper and lower door 

hinge (7) (8) by M5 inner six angle 

screwdriver (Tool 5), then to assemble 

the door hinge on the opposite side 

(Drawing 3 and 4).

6. 

Reverse the door 180 degrees, then 

Summary of Contents for Aurora DA-CN-0353

Page 1: ...Dry Aging Cabinet Model DA CN 0353 Item 47101 Instruction Manual Revised 12 07 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Page 2: ...19 20 21 22 23 Table of Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Troubleshooting Parts Breakdown Electrical Schematics Warran...

Page 3: ...T RESPONSIBLE FOR DIMINISHED COOLING OR ANY DAMAGES DUE TO WATER LEAKS WARRANTY IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED D...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...ue todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o da os visible o oculto por favor anote...

Page 6: ...not suitable for storing frozen food 6 If the cabinet is left empty for a long time please close defrost clean dry and keep the door open to prevent the refrigerant from mold inside the equipment 7 If...

Page 7: ...the product from the main power supply pull out the plug do not pull the cable turn off or remove the fuse 9 Prohibit the use of flammable sprays near the product 10 Forbidden to damage the refrigera...

Page 8: ...during transportation All materials used are Safety and Warranty Unauthorized maintenance will void the warranty Warranty covers electrical and part failures not improper use Please see https omcan co...

Page 9: ...GROUNDING INSTRUCTIONS When installing the product must connect the grounding wire Please use the grounding power socket correctly to prevent the leakage of the wire and reduce the risk of electric sh...

Page 10: ...your cabinet Your cabinet is equipped with 4 adjustable feet to facilitate easy leveling We recommend that you tighten the back feet to the maximum and adjust the front feet to level the cabinet INST...

Page 11: ...n of the door according to the product s own configuration 2 The door may be irreversible depending on the type of handles of the cabinet or the door may need to be opened and replaced when ordering W...

Page 12: ...TION METHOD OF VENTILATION PLINTH Note Not all products need to install the ventilation plinth by themselves please follow the configuration of the actual purchased product 1 Take the front ventilatio...

Page 13: ...igerant gas to produce cold 3 Fan operating sound to circulate the air within the cabinet 4 Pa Pa sound solenoid valve start sound 5 Sizzle sound it is caused by the refrigerant flowing in the pipelin...

Page 14: ...to understand that there is a difference between the temperature inside the cabinet and the temperature shows on display panel You will need to wait approximately 12 hours before noticing the effects...

Page 15: ...omatically defrost when the compressor is stopped and timing The frost water is automatically discharged from the storage area of the ripening machine The water condensed in the container is converted...

Page 16: ...E5 to prompt a water shortage fault When this fault occurs the lighting lamp will flash At this time it is necessary to add water manually The display panel E5 disappears automatically within 10 secon...

Page 17: ...se if any Make sure that the door is closed properly If your cabinet appears to be malfunctioning unplug it and contact your after sales service Any intervention on the cold circuit should be performe...

Page 18: ...Please read carefully the instruction manual and revert to troubleshooting guide chart PROBLEM POSSIBLE CAUSE Cabinet does not operate Not plugged in The appliance is turned off The circuit breaker tr...

Page 19: ...ar gurgling sounds caused by the flow of refrigerant in your cabinet Contraction and expansion of the inside walls may cause popping and crackling noises The cabinet is not level The door will not clo...

Page 20: ...20 Parts Breakdown Model DA CN 0353 47101...

Page 21: ...36 AI463 Humidifier Filter for 47101 8 AI479 UV Light Cover for 47101 22 AI495 Dryer Filter for 47101 38 AI464 12V Ballast for 47101 9 AI480 Humidity Sensor for 47101 23 AI496 Connecting Pipe for 471...

Page 22: ...22 Electrical Schematics Model DA CN 0353 47101...

Page 23: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 24: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: