Safety and Warranty

• 

Install the unit in an indoor, well-ventilated area. 

- Unit performs more efficiently in a well-ventilated area.

 

- For best performance, please maintain clearance of 4” on the back and side of the unit. Brackets should 

be attached on the back of the unit. 

- Outdoor use may cause decreased efficiency and damage to the unit.

• 

Avoid installation in a high humidity and/or dusty area. 

- Humidity could cause unit to rust and decrease efficiency of the unit.

 

- Dust collected on condenser coil will cause unit to malfunction. 

- Malfunction due to dirty condenser will void warranty.

•  Select a location away from heat and moisture-generating equipment.

 

- High ambient temperatures will cause the compressor to overwork, leading to higher energy bills and 

gradual breakdown of the unit. With the lid open, the unit should not be used in areas over 80 degrees. The 

unit should not be used in areas over 90 degrees. 

- Malfunction due to high ambient temperature will void warranty.

ELECTRICAL

•  Please ensure that the required voltage of the compressor is being supplied at all times. Low or high 

voltage can detrimentally affect the refrigeration unit.

• 

All units should be plugged into a grounded and properly-sized electrical outlet with appropriate overcurrent 

protection. Please refer to the electrical requirements on the nameplate.

• 

Please make sure that your unit has its own dedicated outlet.

• 

Do not use an extension cord.

1 YEAR PART AND LABOUR WARRANTY

Within the warranty period, contact Omcan Inc. at 1-800-465-0234 to schedule an Omcan authorized 

service technician to repair the equipment locally.

Unauthorized maintenance will void the warranty. Warranty covers electrical and part failures, not 

improper use.

Please see https://omcan.com/disclaimer for complete info.

WARNING:

The packaging components (cardboard, polyethylene, and others) are classified as normal solid urban waste 

and can therefore be disposed of without difficulty.

In any case, for suitable recycling, we suggest disposing of the products separately (differentiated 

waste) according to the current norms.

DO NOT DISCARD ANY PACKAGING MATERIALS IN THE ENVIRONMENT!

Summary of Contents for 41937

Page 1: ...evised 12 17 2020 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Topping Rails Models RS CN 0004 P 0006 P 0009 P Items 46679 41937 46680 Instruction Manua...

Page 2: ...ntents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Regis...

Page 3: ...GES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE WICKING PAD IS NOT REPLACED EVERY SIX MONTHS AND IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...quina y sta usando ropa apropiada y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el funcionamiento REVISE EL...

Page 6: ...O NOT PUNCTURE REFRIGERANT TUBING CAUTION RISK OF FIRE OR EXPLOSION FLAMMABLE REFRIGERANT USED CONSULT REPAIR MANUAL OWNER S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT ALL SAFETY PRECAUTIONS MUST...

Page 7: ...d warranty ELECTRICAL Please ensure that the required voltage of the compressor is being supplied at all times Low or high voltage can detrimentally affect the refrigeration unit All units should be p...

Page 8: ...ontact Omcan immediately Technical Specifications Model RS CN 0004 P RS CN 0006 P RS CN 0009 P Pan Capacity 4 1 3GN 6 1 3GN 9 1 3GN 8 1 6GN 12 1 6GN 18 1 6GN Refrigerant R600a Electrical 120V 60Hz 1 C...

Page 9: ...the collar for the grub screw faces inwards 2 Slot the two side panels into the collars with the holes in the glass at the top Note Ensure the screw hole furthest from the edge of the panel goes to t...

Page 10: ...10 Installation GLASS ASSEMBLY GUIDE...

Page 11: ...is displayed MANUAL DEFROST The appliance will automatically run a defrost cycle every six hours Note The cycle starts from the time the appliance is initially powered up TO MANUALLY DEFROST THE APPL...

Page 12: ...cord unplugged Plug in power cord Thermostat set too high Set thermostat to lower temperature Cabinet in defrost cycle Wait for defrost cycle to finish Condensing Units Run For Long Periods of Time E...

Page 13: ...13 Parts Breakdown Model RS CN 0004 P 46679 Model RS CN 0006 P 41937 Model RS CN 0009 P 46680...

Page 14: ...for 41937 3 AD833 Pan Support for 41937 11 AD827 Unit Board for 41937 19 AE135 Glass Linking Clip for 41937 4 AD819 Power Cord for 41937 12 AD828 Condenser for 41937 20 AE147 Top Glass for 41937 5 AD...

Page 15: ...15 Electrical Schematics Model RS CN 0004 P 46679 Model RS CN 0006 P 41937 Model RS CN 0009 P 46680...

Page 16: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 17: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: