background image

4

General Information

Omcan Manufacturing and Distributing Company Inc., Food Machinery of America, Inc. dba Omcan 

and Omcan Inc. are not responsible for any harm or injury caused due to any person’s improper or 

negligent use of this equipment. The product shall only be operated by someone over the age of 18, of 

sound mind, and not under the influence of any drugs or alcohol, who has been trained in the correct 

operation of this machine, and is wearing authorized, proper safety clothing. Any modification to the 

machine voids any warranty, and may cause harm to individuals using the machine or in the vicinity of 

the machine while in operation.

CHECK PACKAGE UPON ARRIVAL

Upon receipt of an Omcan shipment please inspect for external damage. If no damage is evident on the 

external packaging, open carton to ensure all ordered items are within the box, and there is no concealed 

damage to the machine. If the package has suffered rough handling, bumps or damage (visible or concealed), 

please note it on the bill of lading before accepting the delivery and contact Omcan within 24 hours, so we may 

initiate a claim with the carrier. A detailed report on the extent of the damage caused to the machine must be 

filled out within three days, from the delivery date shown in the shipping documents. Omcan has no recourse 

for damaged products that were shipped collect or third party.

Before operating any equipment, always read and familiarize yourself with all operation and safety 

instructions.

Omcan would like to thank you for purchasing this machine. It’s of the utmost importance to save 

these instructions for future reference. Also save the original box and packaging for shipping the 

equipment if servicing or returning of the machine is required.

---------------------------------------------------------------------------------------------------------------------------------------------------

Omcan Fabrication et distribution Companie Limité et Food Machinery d’Amerique, dba Omcan et 

Omcan Inc. ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne 

ait utilisé cet équipement de façon irrégulière. Le produit ne doit être exploité que par quelqu’un de 

plus de 18 ans, saine d’esprit, et pas sous l’influence d’une drogue ou d’acohol, qui a été formé pour 

utiliser cette machine correctement, et est vêtu de vêtements de sécurité approprié. Toute modification 

de la machine annule toute garantie, et peut causer un préjudice à des personnes utilisant la machine 

ou des personnes à proximité de la machine pendant son fonctionnement.

VÉRIFIEZ LE COLIS DÈS RÉCEPTION

Dès réception d’une expédition d’Omcan veuillez inspecter pour dommages externes. Si aucun dommage 

n’est visible sur l’emballage externe, ouvrez le carton afin de s’assurer que tous les éléments commandés 

sont dans la boîte, et il n’y a aucun dommage dissimulé à la machine. Si le colis n’a subi aucune mauvaises 

manipulations, de bosses ou de dommages (visible ou cachée), notez-le sur le bond de livraison avant 

d’accepter la livraison et contactez Omcan dans les 24 heures qui suivent, pour que nous puissions engager 

une réclamation auprès du transporteur. Un rapport détaillé sur l’étendue des dommages causés à la machine 

doit être rempli dans un délai de trois jours, à compter de la date de livraison indiquée dans les documents 

d’expédition. Omcan n’a aucun droit de recours pour les produits endommagés qui ont été expédiées ou cueilli 

par un tiers transporteur.

Summary of Contents for 39539

Page 1: ...ised 06 17 2021 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Showcases Models RS CN 0270 0370 0370 S 0470 Items 39539 40519 39540 47105 Instruction Manu...

Page 2: ...nts Section Disclaimer General Information Safety and Warranty Technical Specifications Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registration Model RS...

Page 3: ...NOT RESPONSIBLE FOR ANY DAMAGES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED DIRE...

Page 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Page 5: ...nspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en...

Page 6: ...ower outlet with any other appliance as cable will overheat and may result in a fire Protect cables Extra caution should be used when handling cables as broken or damaged cables can cause sparking and...

Page 7: ...0mm Packaging Dimensions 38 x 28 5 x 51 6 965 x 724 x 1311mm 49 8 x 31 3 x 51 6 1265 x 795 x 1311mm 63 x 29 3 x 50 1600 x 743 x 1270mm Weight 360 5 lbs 163 5 kgs 401 2 lbs 182 kgs Packaging Weight 379...

Page 8: ...cking FRONT PANEL OPERATION 1 Set temperature Press button set temperature will be displayed Press or button to modify and store the displayed value Press button to exit the adjustment and display the...

Page 9: ...the air outlet and suction to keep the air circulation and refrigeration capability constant Do not overfill refrigerator with food as it will influence the cooling effect If needed adjust the rack h...

Page 10: ...ck the air suction or outlet Regulate the temperature controller Noisy The refrigerator is not level The refrigerator contacts the wall or other matter There is loose part in refrigerator Contact Omca...

Page 11: ...11 Parts Breakdown Model RS CN 0270 39539...

Page 12: ...op Upper Door Frame for 39539 32 71133 Power Cord Fixer for 39539 54 71049 Left Glass Fixer for 39539 11 71069 Door Glass for 39539 33 71083 Dryer Filter for 39539 55 41966 Shelf Bracket Bottom Right...

Page 13: ...13 Parts Breakdown Model RS CN 0370 40519...

Page 14: ...oor Handle for 40519 30 71089 Water Tray for 40519 52 68272 Left Glass Fixer for 40519 10 AF488 Left Doorframe for 40519 31 71133 Power Cord Fixer for 40519 53 68271 Right Glass Fixer for 40519 11 711...

Page 15: ...15 Parts Breakdown Model RS CN 0370 S 39540...

Page 16: ...ray for 39540 54 68171 Left Glass Fixer for 39540 10 71110 Door Handle for 39540 32 71133 Power Cord Fixer for 39540 55 68170 Right Glass Fixer for 39540 11 68190 Left Door Frame for 39540 33 71083 Dr...

Page 17: ...17 Parts Breakdown Model RS CN 0470 47105...

Page 18: ...7105 31 68250 Back Grill for 47105 53 AG486 Front Glass Fixer for 47105 11 AF514 Top Door Frame for 47105 32 71089 Water Tray for 47105 54 68272 Left Glass Fixer for 47105 12 68244 Door Glass for 4710...

Page 19: ...19 Electrical Schematics Model RS CN 0270 39539 Model RS CN 0370 40519 Model RS CN 0370 S 39540...

Page 20: ...20 Electrical Schematics Model RS CN 0470 47105...

Page 21: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 22: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Page 23: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 24: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: