![Omcan 31861 Instruction Manual Download Page 9](http://html1.mh-extra.com/html/omcan/31861/31861_instruction-manual_736093009.webp)
9
Installation
NSF APPROVED SEALANTS:
• Minnesota Mining #ECU800 Caulk.
• Minnesota Mining #ECU2185 Caulk.
• Minnesota Mining #ECU1055 Bead.
• Minnesota Mining #ECU1202 Bead.
• Armstrong Cork - Rubber Caulk.
• Products Research Co #5000 Rubber Caulk.
• GE Silicone Sealer.
• Dow Corning Silicone Sealer.
NOTE:
Asphalt floors are very susceptible to chemical attack. A layer of tape on the floor prior to applying the
sealant will protect the floor.
Operation
START UP
Plug in the cooler and the compressor is ready to operate.
• Temperature control set at #4 position gives the cooler an approximate temperature of 35°F. Allow unit to
function several hours, completely cooling cabinet before changing the control setting.
• Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to
replace the temperature control it should be ordered from your dealer or recommended service agent.
• Good air flow in your cooler is critical. Be careful to load product so that it neither presses against the back
wall nor comes within four (4) inches of the evaporator housing. Refrigerated air off the coil must circulate
down the back wall.
LIGHT SWITCH LOCATION:
The switch is located on the front of the evaporator housing toward the right of the cabinet. Open the front
door.
NOTE:
If the unit is disconnected or shut off, wait five (5) minutes before re-starting unit.
RECOMMENDATION
Before loading product the unit should be run for 2 to 3 days. This allows confirmation that the electrical wiring
and installation are correct and no shipping damage has occurred. Remember that the factory warranty does
not cover product loss.
Summary of Contents for 31861
Page 18: ...18 Parts Breakdown Model BB CN 0020 G 31863 Model BB CN 0020 S 37549...
Page 20: ...20 Electrical Schematics Model BB CN 0012 G 31861 Model BB CN 0012 S 37547...
Page 21: ...21 Model BB CN 0016 G 31862 Model BB CN 0016 S 37548 Electrical Schematics...
Page 22: ...22 Electrical Schematics Model BB CN 0020 G 31863 Model BB CN 0020 S 37549...