6
Installation
Position your unit on a stable level surface and plug in the supplied cord into any grounded 120-volt AC, 15
amps power supply dedicated breaker. It does not require a dedicated circuit but is designed for use with the
power cord supplied with the unit. It is highly recommended that you use ONLY the power cord supplied. Use
of a dedicated circuit should insure operational efficiency. Do not operate the unit with an extension cord.
ELECTRICAL CONTROLLER INSTALLATION
1. Remove the electrical control box from the packaging material.
2. Insert the electrical cord through the hole at the bottom of the cabinet.
3. Slide the electrical control box into the bottom slot of the cabinet.
Operation
1.
Push main power switch (ON/ OFF rocker) to “ON” position.
2.
Push HEAT/ PROOF switch to HEAT for heating ONLY.
3.
Turn HEAT thermostat knob fully clockwise for preheat.
4. Allow 45 minutes for pre-heating, then turn thermostat to desired setting.
5.
Place water in the “water pan” filling to about 3/4 full, for proofing.
6.
For proofing, push HEAT/ PROOF switch to PROOF.
7. Adjust the heat and humidity thermostat knob to control desired temperature and humidity. Allow 45
minutes for pre-heating.
NOTE: The internal air circulation blower and 900W heater element (controlled with the “Heat”
Thermostat) will operate continuously when the power switch is turned “ON”.
HEAT THERMOSTAT
The controlling range is 80°F to 185°F. The dial has numbers 1 thru 9 that do not relate to a specific calibrated
temperature. Temperature settings must be obtained through familiarization with the unit. The dial also has an
“OFF” position to turn heater unit off.
HUMIDITY THERMOSTAT
To control humidity range from 30% to 100%, humidity settings must be obtained through familiarization with
the unit. The dial has numbers 1 thru 9 that do not relate to a specific calibrated humidity. The dial also has an
“OFF” position to turn humidity off.
To maintain low heat range between 85°F - 100°F (29.4°C - 37.8°C), switch to proof mode and adjust heat
knob to desired heat range. Allow 45 minutes to pre-heat in proof cycle.