background image

6

Installation

Position your unit on a stable level surface and plug in the supplied cord into any grounded 120-volt AC, 15 

amps power supply dedicated breaker. It does not require a dedicated circuit but is designed for use with the 

power cord supplied with the unit. It is highly recommended that you use ONLY the power cord supplied. Use 

of a dedicated circuit should insure operational efficiency. Do not operate the unit with an extension cord.

ELECTRICAL CONTROLLER INSTALLATION

1.  Remove the electrical control box from the packaging material.

2.  Insert the electrical cord through the hole at the bottom of the cabinet.

3.  Slide the electrical control box into the bottom slot of the cabinet.

Operation

1. 

Push main power switch (ON/ OFF rocker) to “ON” position.

2. 

Push HEAT/ PROOF switch to HEAT for heating ONLY.

3. 

Turn HEAT thermostat knob fully clockwise for preheat.

4.  Allow 45 minutes for pre-heating, then turn thermostat to desired setting.

5. 

Place water in the “water pan” filling to about 3/4 full, for proofing.

6. 

For proofing, push HEAT/ PROOF switch to PROOF.

7.  Adjust the heat and humidity thermostat knob to control desired temperature and humidity. Allow 45 

minutes for pre-heating.

NOTE: The internal air circulation blower and 900W heater element (controlled with the “Heat” 

Thermostat) will operate continuously when the power switch is turned “ON”.

HEAT THERMOSTAT

The controlling range is 80°F to 185°F. The dial has numbers 1 thru 9 that do not relate to a specific calibrated 

temperature. Temperature settings must be obtained through familiarization with the unit. The dial also has an 

“OFF” position to turn heater unit off.

HUMIDITY THERMOSTAT

To control humidity range from 30% to 100%, humidity settings must be obtained through familiarization with 

the unit. The dial has numbers 1 thru 9 that do not relate to a specific calibrated humidity. The dial also has an 

“OFF” position to turn humidity off.

To maintain low heat range between 85°F - 100°F (29.4°C - 37.8°C), switch to proof mode and adjust heat 

knob to desired heat range. Allow 45 minutes to pre-heat in proof cycle.

Summary of Contents for 31834

Page 1: ...Revised 12 10 2018 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Heat Proofer Items 39528 31834 43554 Instruction Manual ...

Page 2: ...14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registration Item 39528 Item 31834 Item 43554 ...

Page 3: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Page 4: ...e exterior Habra el carton para asegurararse que todos los articulos solicitados ésten dentro de la caja y no encuentre daños ocultos en la máquina Si el paquete ha sufrido un manejo de poco cuidado golpes o daños visible o oculto por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas de modo que podamos iniciar una reclamación con la compañia Un informe ...

Page 5: ...ical 120V 60 1 N A Dimensions 29 5 x 18 1 x 7 749 x 461 x 178mm 21 x 30 8 x 68 533 x 781 x 1727mm 21 x 32 x 30 7 537 x 813 x 779mm Installation UNPACKING Examine the interior of the unit to make sure all packing materials are removed before the unit is plugged into an electrical outlet Examine the interior and exterior to determine whether any damage was incurred during delivery If so notify the c...

Page 6: ... setting 5 Place water in the water pan filling to about 3 4 full for proofing 6 For proofing push HEAT PROOF switch to PROOF 7 Adjust the heat and humidity thermostat knob to control desired temperature and humidity Allow 45 minutes for pre heating NOTE The internal air circulation blower and 900W heater element controlled with the Heat Thermostat will operate continuously when the power switch i...

Page 7: ...Hamburgers Covered 180 82 2 Lasagna Covered 185 85 Potatoes Baked Uncovered 180 82 2 Potatoes Mashed Covered 175 79 4 Potatoes Scalloped Covered 175 79 4 Pancakes Covered 175 79 4 Pasta Covered 180 82 2 Peas Covered 170 175 76 7 79 4 Pizza Uncovered 175 180 79 4 82 2 Roast Beef Uncovered 170 180 76 7 82 2 Roast Pork Uncovered 170 180 76 7 82 2 Strip Steak Uncovered 160 170 71 1 76 7 Turkey Uncover...

Page 8: ...es will short out on the metal causing permanent damage Both the element and main power switch with wires on switch must be replaced Maintenance and U S Public Health Service standards Non toxic chemical cleaners or mild detergents are recommended for cleaning of fixtures DO NOT use steel wools of any kind Steel wool particles will work into the grains of the metal causing corrosion Also these par...

Page 9: ...long with its power supply transformer REFERENCE Item Number Model Number Description Manufacturer Model Number 39528 Electric Control Box for Heat Proofer 120V 60HZ cQPSus NHP PD ECO 31834 Non Insulated Heater Proofer Cabinet 21 x 30 75 x 68 NIHP 43554 Non Insulated Heater Proofer Cabinet 32 x 20 5 x 30 5 NIHP 1810 ...

Page 10: ...10 Parts Breakdown Item 39528 ...

Page 11: ...2A 75258 L E D Thermometer for NHP PD ECO 2 75261 Power Inlet for NHP PD ECO 9 75269 Thermostat Control Knob for NHP PD ECO 13 14 75259 Thermometer Transformer for NHP PD ECO 2A 75265 900W Heater Element for NHP PD ECO 10 68291 Circuit Breaker for NHP PD ECO 15 75260 Heat Proof Switch for NHP PD ECO 3 75266 600W Heater Element for NHP PD ECO 11 Item No Description Position Item No Description Posi...

Page 12: ...12 Electrical Schematics Item 39528 ...

Page 13: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Page 14: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Page 15: ...gister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Catere...

Page 16: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 5000 produ...

Reviews: