Before starting installation work:
Access to the site, installation, commissioning and
maintenance of the system must be performed
only by expert personnel.
-
Install safety devices to protect personnel
and prevent them falling (for example
platform or harnesses)
-
Cover (safely)any open floor or walls
-
Use safe installation tools and objects that
prevent accidental falls
-
Open stroke chambers must be closed and
warning
notices must be
prominently
displayed when working in open areas.
Work involving electrical equipment must be
carried out by an electrician or qualified person.
1.5
Cleaning and pollution precautions
Impurities and dirt inside the hydraulic system
cause faults and wear.
All parts of the system that are dismantled for
controls or repair, as also the pipes and fittings,
must be completely clean before they are refitted.
Any oil leaks from the circuit during repair
operations must not leak into the environment but
must be immediately cleaned up with rags or
sponges.
2
Installation manual
2.1
Installation manual
– Mechanical
installation
2.1.1
General information
Before starting installation, it is in your
interest to check the structural and spatial
limits within which you will have to work.
Consider where (workshop or elsewhere) and
when the assembly methods have to be applied.
All the relevant conditions must therefore be
considered in advance that relate to the various
work procedures and no action should be taken
without first considering the consequences. Check
that the goods received contain everything
requested and that all the products and individual
parts are as prescribed and have not been
damaged during transit.
The information on the rating plate must be
compared with the order form.
During the period of storage, keep the
material in its original package, protected
from bad weather and direct exposure to the sun
in
order
to
avoid
accumulations
of
water/condensation that could occur inside the
packaging. (See technical data on temperature
and humidity limits). Never dump packaging
material in the environment. Once the product has
been dismantled, it must be disposed of correctly
in compliance with local laws; do not dump in the
environment. Before recycling, check the nature of
the various materials and recycle in the prescribed
manner.
OMARLIFT accepts no liability for harm
arising from tampering with (or changes
to) the packaging material by third parties.
Any installation situation that is different
from the original situation proposed must
be discussed with OMARLIFT. Any situation that
is not allowed by OMARLIFT (for reasons of
patents, legal, technical or other reasons) is
considered to be the responsibility of the installing
technician and may void the warranty.
Follow these points when installing or replacing
components of the hydraulic system:
-
Always bring the lift cabin to rest on the
shock absorbers;
-
Make sure that the lift cannot be actuated
accidentally by switching off the master
switch;
-
Before opening any part of the hydraulic
circuit, removing plugs or loosening fittings,
always reduce oil pressure to zero.
-
In the event of welding operations, prevent
waste coming into contact with oil or with the
rod and its seals and all the elastic parts of
the system;
-
Eliminate the oil loss, eliminate oil leaks,
maintain the system clean at all times so
that any leaks can be easily identified and
eliminated.